20098687
18
GB
Installation
5.9
Closing the burner
With the adjustment of the head completed:
➤
refit the burner 4)(Fig. 15) on the guides 3) at about 100 mm
from the pipe coupling 5) - burner in the position shown in
Fig. 12 on page 17;
➤
insert the probe cable and the electrode cable, then slide the
burner as far as the pipe coupling, with the burner in the
position shown in Fig. 15.
➤
Refit screws 2) on slide bars 3).
➤
Fix the burner to the pipe coupling with the screw 1) and put
back the split pin in one of the two slide bars 3).
➤
Reconnect the articulated coupling 8) to the graduated sec-
tor 7).
WARNING
When fitting the burner on the two slide bars, it is
advisable to gently draw out the high voltage ca-
ble and the flame detection probe cable until they
are slightly stretched.
Fig. 15
D1085