81
ENGLISH
In cooling mode, the water flowing temperature (TW_out) range in dif
-
ferent outdoor temperature (T4) is listed below:
Operation range by heat pump with possible limitation
and protection.
-
In heating mode, the water flowing temperature (TW_out) range in dif
-
ferent outdoor temperature (T4) is listed below:
In DHW mode, the water flowing temperature (TW_out) range in diffe
-
rent outdoor temperature (T4) is listed below:
3 ACCESSORIES
Accessories supplied with the unit
Installation Fittings
Name
Shape
Quantity
Installation and owner’s manual(this book)
1
Remote control
manual
1
Y-shape filter
1
Wired controller
1
Thermistor for domestic hot water tank or
zone2 water flow or balance tank
1
Drain hose
1
Energy label
1
Tighten belt for customer wiring use
2
3
Network adapting wire
1
Accessories avaliable from supplier
Thermistor for balance tank(Tbt1)
1
Extension wire for Tbt1
1
Thermistor for Zone 2 flow temp.(TW2)
1
Extension wire for TW2
1
Thermistor for solar temp.(Tsolar)
1
Extension wire for Tsolar
1
Thermistor and extension wire for Tbt1, TW2, Tsolar can be shared,
if these functions are needed at the same time, and 10m in length of
the sensor cable please order these thermistors and extension wire
additionally.
4 BEFORE INSTALLATION
Before installation
Be sure to confirm the model name and the serial number of the unit.
Handling
Due to relatively large dimensions and heavy weight, the unit should
only be handled using lifting tools with slings. The slings can be fitted
into foreseen sleeves at the base frame that are made specifically
for this purpose.
Summary of Contents for 20191845