113
ENGLISH
CN11
CODE
CONNECT TO
1
1
SL1
Solar energy input
signal
2
SL2
2
3
HL
Room thermostat input
(high voltage)
4
CL
15
L1
3
5
1ON
SV1 (3-way valve)
6
1OFF
16
N
4
7
2ON
SV2 (3-way valve)
8
2OFF
17
N
5
9
PUMP C
Pumpc (zone2 pump)
21
N
6
10
PUMP O Outside circulation pump
/zone1 pump
22
N
7
11
P S
Solar energy pump
23
N
8
12
P D
DHW pipe pump
24
N
9
13
TBH
Tank booster heater
16
N
10
14
IBH1
Internal backup heater 1
17
N
11
18
N
SV3 (3-way valve)
19
3ON
20
3OFF
CN30
CODE
CONNECT TO
1
1
A
Wired controller
2
B
3
X
4
Y
5
E
2
6
P
Outdoor unit
7
Q
3
9
H1
Cascade connected heat pump
10
H2
CN7
CODE
CONNECT TO
1
26
R2
Compressor run
30
R1
31
DFT2 Defrost run
32
DFT1
2
25
HT
Antifreeze E-heating
tape (external)
29
N
3
27
AHS1 Additional heat source
28
AHS2
Port provide the control signal to the load.Two kind of control signal port:
Type 1: Dry contact without voltage.
Type 2: Port provide the signal with 220V voltage. If the current of load is <0.2A, load can connect to the port directly.
If the current of the load is ≥0.2A, connect the load through a relay.
1 2 3
4 5
6 7 8 910
11
12
2
4
23
21
20
19
18
131415
16 17
CN11
22
30
26
1
2 3 4 5
6
7 8 9 10
CN30
CN7
Type 1
Running