INStAllAtION

L

P

H

Model

20

25

35

50

70

Product dimensions

H

280

280

280

322

336

mm

L

855

855

855

997

1115

mm

P

200

200

200

230

243

mm

Weight

10,0

10,0

10,0

13,0

16,0

kg

2.4

 Storage

The product must be stored of according to the regulations 
in force.

2.5

  Handling and removal of the packing

before unpacking, personal protective clothing should be 
worn and used transport means and tools suitable for the 
size and weight of the unit.

The product can be handled manually.

 Handles

1

1

 Document envelope and material supplied as kit

 Polystyrene  elements

2

1

Follow the below instructions for packing removal and product 
handling:

 

transport the equipment in the installation place

 

open the cardboard packaging

 

remove the document envelope

 

take out the device by lifting it up

 

remove the polystyrene elements

 

remove the polyethylene bag

In manual operation it is compulsory to respect always the 
maximum weight per person provided for by the national 
laws and standards.

Handle with care

The packing material must not be disposed of in the sur-
rounding environment and must be kept out of children 
reach, as it can be dangerous. It must be disposed of ac-
cording to the regulations in force.

2.6

  Place of installation

The location of 

R

 

AMW P

 devices must be determined by the 

system's designer or by another competent person, and must 
take into account the technical requirements, as well as any 
current local regulations.

R

 

AMW P 

is designed for indoor wall installation:

 

install the indoor unit in the room to be air-conditioned

 

its position must allow for the circulation of treated air in 
the whole room

 

consider an area where there are no obstacles to the reg-
ular air delivery and intake

 

The R32 refrigerant gas is slightly inflammable and odour-
less. Carefully read the safety data sheet available from the 
dealer.

The product uses R32 refrigerant gas and must be installed 
in rooms with a minimum floor area, as indicated in the 
following table, depending on the total refrigerant charge 
of the system (given by the sum of the factory charge of the 
outdoor unit and, if appicable, the additional charge).

The amount of refrigerant charged inside the unit refer to 
the INSTALLATION AND TECHNICAL SERVICE INSTRUCTIONS of out-
door unit used.

Summary of Contents for 20127839

Page 1: ...AMW P SERIES R32 06 2018 cod Doc 0083009 rev 3 EN INSTALLATION AND TECHNICAL SERVICE INSTRUCTIONS...

Page 2: ...ting from the product s date of purchase Find the nearest Authorised Technical Support by visiting the website 9 WARNING Keep the product purchase documents for tax purposes to be presented to the Aut...

Page 3: ...INGANDMAINTENANCE p 20 3 1 Preparation for first commissioning p 20 3 2 Putting into service p 21 3 3 Temporary shutdown p 21 3 4 Stop for an extended period of time p 21 3 5 Ordinary maintenance p 22...

Page 4: ...ot perform any interventions upon the device on your own 9 The units contain refrigerant gas operate carefully so as to avoid damaging the gas circuit and the fin bank 9 Any gas leaks indoors can gene...

Page 5: ...tected value to the control panel in order to control the operation of the outdoor unit and regulate the room temperature 9 Safety device replacement must be carried out by R Technical Support Service...

Page 6: ...Cooling sound levels Superminimum sound pressure 1 20 20 22 28 30 dB A Minimum sound pressure 1 25 25 29 33 37 dB A Medium sound pressure 1 30 30 33 37 43 dB A Maximum sound pressure 1 35 35 38 41 47...

Page 7: ...Italian Instruction s book for the installer and for the Technical Service in English user instruction booklet in Italian user instruction booklet in English Warranty Spare parts labels contact sheets...

Page 8: ...not be disposed of in the sur rounding environment and must be kept out of children reach as it can be dangerous It must be disposed of ac cording to the regulations in force 2 6 Place of installatio...

Page 9: ...the supplied wall plugs are suitable for the chosen support wall Avoid installing the device in hallways or passageways any obstacles or barriers that will cause the expelled air to recirculate locat...

Page 10: ...evices are supplied with a metallic support to fix them to the wall MODEL 20 25 35 1 Fastening slots 2 Fastening holes 3 Metal support 4 Equipment overall dimensions 5 Metal support central axis 6 Equ...

Page 11: ...as pre charged with nitrogen 1 Liquid pipe 2 Gas pipe 3 Gas connection plug 4 Pressure presence indicator 5 Fluid connection plug 1 2 3 4 5 ensure that pressure presence indicator is protruding parti...

Page 12: ...m the prearranged connec tion on the right hand side 1 Drainage pipe 2 Condensation discharge 1 2 remove the drainage pipe on the left hand side and place it on the right hand side fit the protection...

Page 13: ...es water 9 Avoid the entry of uncondensable gases air in the circuit otherwise with the unit in operation high pressures with the risk of damages might ensue 9 Use copper pipes for cooling systems 0 0...

Page 14: ...ousehold appliances electric stoves etc 9 As for circuit leak and pneumatic vacuum tests refer to the matching outdoor unit instruction booklet for the installer Pipe insulation Connection pipes must...

Page 15: ...irect it toward a suitable place for discharge insulate the joints 50 9 The discharge system must feature a suitable syphon in or der to prevent air from entering the vacuum system The sy phon also pr...

Page 16: ...n motor C0N2 C0N3 CN11 Display SW2 1 2 3 4 ON CN1 CN36 Remote controller receiver 2 14 Electrical connection AMW P it leaves the factory completely wired and only requires a connection to the outdoor...

Page 17: ...ing sys tem for any electrical intervention always refer to the wiring diagrams contained within this booklet take anti static precautions in case of weather conditions where humidity is less than 40...

Page 18: ...duling and motor driven deflector settings Function keys with door open It activates and deactivates the automatic movement of the horizontal deflector or stops it in a specific position It activates...

Page 19: ...Smart mode enabled Timer settings Timer setting value or current time display Switch on timer enabled Switch off timer enabled Motor driven deflector settings Horizontal deflector position Vertical d...

Page 20: ...ctivated via external control if contact CN51 is closed the unit can be activated via ex ternal control OFF disabled if contact CN51 is open the unit switches off but it can be activated via external...

Page 21: ...ouble acoustic signal is emitted the air conditioner starts in cooling mode with high ven tilation speed and active air deflector To switch off press the emergency switch again 9 This operation must b...

Page 22: ...el wet a sponge or soft cloth with water and soap to wash once cleaning is over dry surfaces with care 9 Do not use water at a temperature that is higher than 40 C powder or abrasive detergents solven...

Page 23: ...e system s main switch in the OFF position disconnect the cooling pipes disconnect the condensate discharge disconnect the electric connections push up and release the unit from its metallic support l...

Page 24: ...and disposal 4 DISPOSAL Packaging materials shall be disposed of separately so as to re cover and recycle them At the end of its service life the device shall be disposed of according to the existing...

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ...39 0442 630111 fax 39 0442 630371 www riello it As the manufacturer is constantly improving its products the aesthetic or dimensional features the technical data the equipment and accessories indicat...

Reviews: