8
INStAllAtION
L
P
H
Model
20
25
35
50
70
Product dimensions
H
280
280
280
322
336
mm
L
855
855
855
997
1115
mm
P
200
200
200
230
243
mm
Weight
10,0
10,0
10,0
13,0
16,0
kg
2.4
Storage
9
The product must be stored of according to the regulations
in force.
2.5
Handling and removal of the packing
9
before unpacking, personal protective clothing should be
worn and used transport means and tools suitable for the
size and weight of the unit.
The product can be handled manually.
1
Handles
1
1
1
Document envelope and material supplied as kit
2
Polystyrene elements
2
1
Follow the below instructions for packing removal and product
handling:
—
transport the equipment in the installation place
—
open the cardboard packaging
—
remove the document envelope
—
take out the device by lifting it up
—
remove the polystyrene elements
—
remove the polyethylene bag
9
In manual operation it is compulsory to respect always the
maximum weight per person provided for by the national
laws and standards.
9
Handle with care
9
The packing material must not be disposed of in the sur-
rounding environment and must be kept out of children
reach, as it can be dangerous. It must be disposed of ac-
cording to the regulations in force.
2.6
Place of installation
The location of
R
AMW P
devices must be determined by the
system's designer or by another competent person, and must
take into account the technical requirements, as well as any
current local regulations.
R
AMW P
is designed for indoor wall installation:
—
install the indoor unit in the room to be air-conditioned
—
its position must allow for the circulation of treated air in
the whole room
—
consider an area where there are no obstacles to the reg-
ular air delivery and intake
—
The R32 refrigerant gas is slightly inflammable and odour-
less. Carefully read the safety data sheet available from the
dealer.
9
The product uses R32 refrigerant gas and must be installed
in rooms with a minimum floor area, as indicated in the
following table, depending on the total refrigerant charge
of the system (given by the sum of the factory charge of the
outdoor unit and, if appicable, the additional charge).
9
The amount of refrigerant charged inside the unit refer to
the INSTALLATION AND TECHNICAL SERVICE INSTRUCTIONS of out-
door unit used.