Riello 20127134 Installer, Technical Assistan Ce Service And User Manual Download Page 3

3

GENERAL INFORMATION

GENERAL INFORMATION

 

9

The system must be installed by specialist personnel. Use 

only the assembly material supplied with the solar collec-

tor. The supporting framework and all masonry or brickwork 

fixing points must be checked by a person expert in static 

loading, and must be suitable for the nature of the instal-

lation site.

 

9

The solar collector must only be installed on roofs or frames 

that are strong enough to support its weight. The strength 

of the roof or frame must be verified on site by a person 

expert in static loading before the solar collector is installed. 

During this process, it is important to verify the suitability 

of the supporting frame to hold the screw fasteners that fix 

the solar collector in place. An expert in static loading must 

verify that the entire frame complies with relevant stand-

ards, especially in areas liable to snow and areas exposed 

to high winds. Conditions (gusts of wind, formation of wind 

vortices, etc.) at the point where the solar collector is to be 

installed must be carefully considered since these can in-

crease the loads on the supporting structure.

 

9

Solar collector pipes must be connected through a (yel-

low-green) connector of at least 16 mm

2

 Cu (H07 V-U o R) 

to the potential compensation main bar. If a lighting rod is 

already installed, collectors can be integrated in the exist-

ing system. If this is not the case, it is possible to carry out 

earthing with a buried earth cable. The earth duct must be 

laid outside the house. Furthermore, the earth cable must 

be connected to the compensation bar through a duct hav-

ing the same diameter.

 

9

All pipes in the water circuit must be insulated in conform-

ity to relevant standards. Lagging and insulation must be 

protected against damage by the weather and birds and 

animals.

 

9

The collector is suitable for a minimum inclination of 15°, up 

to a maximum of 75°.

 

9

This instruction manual is an integral part of the product. It 

must be kept safe and must ALWAYS accompany the product, 

even if it is sold to another owner or transferred to another 

user or to another installation. If you lose this manual, or-

der a replacement immediately. Keep the product purchase 

documents to be presented to the 

R

 authorised Technical 

Assistance Service to request a service call under warranty.

 

9

Size the solar expansion tank so as to ensure complete ab-

sorption of the expansion of the fluid contained within the 

system, with reference to the prevailing regulations on the 

matter. In particular, consider fluid characteristics, consid-

erable fluctuation of service temperature and vapour that 

might be generated during solar collector stagnation stage. 

Proper size of expansion tank ensures setting off of all vol-

ume changes of the heat transfer fluid, avoiding excessive 

pressure increase. Limited pressure changes avoid reach-

ing safety valve opening pressure and the consequent fluid 

drainage.

PRECAUTIONS

 

9

Always wear safety goggles when drilling. Always wear safe-

ty shoes, cut-proof protective gloves and a safety helmet 

when performing installation work.

 

9

Before beginning installation work on roofs, install the nec-

essary fall prevention and fall arrest devices and ensure that 

all applicable safety standards are applied. Use only tools 

and materials that conform to the safety standards that are 

applicable in the place of work.

 

9

Use only overalls with harness (with lacing or restraining 

belt, connection ropes or bands, fall dampeners, heat sinks) 

certified for the risk detected according to the type of cover-

ing and allowing operating in complete safety.

 

9

The use of ladders leaned against walls can lead to serious 

falls if the ladder slips, slides of falls. When using ladders, 

always ensure that they are stable, and that suitable ladder 

stops are present. If possible secure the ladder with hooks. 

Make sure that there are no live electrical wires near the 

ladder.

 

0

Never attempt to install the system without using suitable 

personal  protection  equipment  and without  following  all 

applicable occupational safety standards.

 

0

Do not touch the product when barefoot or wet if it has any 

electrical accessories installed in it.

 

0

Never  clean  or  service  the  storage  cylinder  without  first 

turning the mains power switch OFF to disconnect all elec-

trical accessories (if fitted) from the mains electricity supply.

 

0

If solar plant pressure decreases, it is forbidden to top up 

with only water as there is a danger of freezing and over-

heating.

 

0

Do not dispose of packaging material into the environment, 

or leave it within the reach of children, since it can become 

a potential hazard. Dispose of packaging material in com-

pliance with applicable legislation.

Summary of Contents for 20127134

Page 1: ...cod 20134553 rev 1 10 2017 RPS 25 2 EVO EN INSTALLER TECHNICAL ASSISTANCE SERVICE AND USER MANUAL...

Page 2: ...tion manual and that it con forms to all applicable laws and standards 9 9This product must only be used for the purpose for which it is designed and made as specified by R R declines all responsibili...

Page 3: ...ssistance Service to request a service call under warranty 9 9Size the solar expansion tank so as to ensure complete ab sorption of the expansion of the fluid contained within the system with referenc...

Page 4: ...9806 Certif 13000000 BAR CODE 128B Anno di produzione SERIALE PROGRESSIVO Year of production Data label To be applied to the back of the solar collector on installation Serial number plate Data plate...

Page 5: ...5 2 EVO Total area 2 301 m2 Exposed area 2 152 m2 Effective absorption area 2 141 m2 Water connections 1 M 1 F Empty weight 41 5 kg Liquid content 1 6 l Recommended flow rate for panel line 30 l h x m...

Page 6: ...ounding air and with total solar radiation of 1000 W m2 referred to the exposed area Pressure drop in solar collectors PRESSURE DROP mbar 50 40 30 20 10 0 25 0 50 75 100 125 150 0 50 100 150 200 250 3...

Page 7: ...allation 8 HANDLING Separate the solar collector from the wooden pallet by removing the film wrapping Apply the data label provided in the document enve lope to the back of the solar collector Once yo...

Page 8: ...or sloping roof mounting frames to install any other equipment They are designed only for use with R solar water heating systems The installation of the solar field changes the pre existing struc ture...

Page 9: ...of installations on flat roofs that cannot be drilled use ballasts not supplied fairly distributed on all the bearing points as shown in the figure kg Wind speed km h Inclination angle of solar colle...

Page 10: ...d flows through them in series Connection with the heat exchange circuit towards the exchanger must be made on the side of probe socket T of the last collector of the series see figure The positioning...

Page 11: ...leave them free to absorb thermal expansion If this is not possible fit an expansion joint at each end 12 SOURCE WATER SYSTEM 1 Solar collector 2 Storage cylinder 3 Collector probe 4 Disconnect valves...

Page 12: ...solar M T 14 DEVICE CLEANING AND MAINTENANCE 9 9The following operations must be exclusively performed by Technical Assistance Service It is recommended to clean the glass once a year as the deposit...

Page 13: ...o clean the glass once a year as the deposit of dust and leaves reduces system efficiency To check the heat transfer fluid to verify its effectiveness every two years To check the integrity of solar c...

Page 14: ...14 END USER END USER...

Page 15: ...15 END USER END USER...

Page 16: ...lo 7 37045 Legnago VR www riello com The manufacturer strives to continuously improve all products Appearance dimensions technical specifications standard equipment and accessories are therefore liabl...

Reviews: