START KI - KIS
16
ENGLISH
17
DESCRIPTION
START 28 KI
START 24 KIS
START 28 KIS
START 35 KIS
Gas
G20
G30
G31
G20
G30
G31
G20
G30
G31
G20
G31
Appliance category ●
Country of destination
II2H3+ ● JO-SRB-
MK-LB-EG-AL
II2H3+ ● JO-SRB-
MK-LB-EG
II2H3+ ● JO-SRB-
MK-LB-EG-AL
II2H3P ● JO-SRB-
MK-LB-EG-AL
II2H3B/P ● AL
Device type
B
11BS
B22P-B52P; C12-C12x;
C22; C32-C32x; C42-C42x;
C52-C52x; C62- C62x;
C82-C82x; C92-C92x
B22P-B52P; C12-C12x;
C32-C32x; C42-C42x;
C52-C52x; C62- C62x;
C82-C82x; C92-C92x
B22P-B52P; C12-C12x;
C32-C32x; C42-C42x;
C52-C52x; C62- C62x;
C82-C82x; C92-C92x
Heating
Nominal heat input
kW
31,90
25,80
30,50
37,60
Nominal heat output
kW
28,71
23,94
28,37
34,93
Reduced heat input
kW
14,00
8,90
12,70
12,90
Reduced heat output
kW
11,93
7,61
11,00
10,82
Domestic hot water
Nominal heat input
kW
31,90
25,80
30,50
37,60
Nominal heat output
kW
28,71
23,94
28,37
34,93
Reduced heat input
kW
8,70
8,90
10,50
12,90
Reduced heat output
kW
7,41
7,61
9,09
10,82
Useful efficiency Pn
max - Pn min
%
90,0 - 85,2
92,8 - 85,5
93,0 - 86,6
92,9 - 83,9
Useful efficiency
30% (47° return)
%
89,5
90,9
91,9
92,5
Combustion efficiency
%
91,2
93,0
92,5
93,0
Flue gas mass flow
rate maximum power
g/s
18,855
17,868
18,484
14,308
13,985
14,120
17,788
17,474
18,075
21,091
21,147
Flue gas mass flow rate
minimum power (CH)
g/s
16,978
15,833
16,423
16,247
16,429
16,683
18,226
18,399
18,836
21,749
22,093
Flue gas mass flow rate
minimum power (DHW)
g/s
10,550
9,839
10,206
-
-
-
15,069
15,212
15,573
Air flow rate
Nm
3
/h
50,960
48,088
49,811
39,613
40,249
40,454
48,052
47,071
48,749
56,894
56,920
Flue flow rate
Nm
3
/h
54,160
50,432
52,285
42,204
41,008
41,455
51,112
49,312
51,114
60,666
59,837
Excess air index (λ)
maximum power
1,668
1,653
1,687
1,608
1,715
1,699
1,645
1,692
1,727
1,580
1,636
Excess air index (λ)
minimum power
3,484
3,403
3,481
5,335
5,741
5,734
4,134
4,378
4,418
4,866
5,112
Flue temperature
(min/max power)*
°C
132/97 132/100 138/102 142/109 143/108 143/108 160/125 160/124
159/124
148/113
145/115
CO
2
at maximum*/
minimum*
%
6,7/3,1
8,2/3,9
7,8/3,7
7,3/2,2
8,2/2,5
8,1/2,4
6,8/2,6
8,0/3,0 7,65/2,9
7,1/2,2
8,1/2,5
CO S.A. at max*/
min* less than
p.p.m.
90/20
180/20
80/30
120/200 140/220 120/200 80/150
80/160
70/150
100/200
70/250
NOx S.A. at max*/
min* less than
p.p.m.
170/80 280/140 220/130 200/100 270/110 260/110 140/110 180/120 180/120
140/100
200/120
NOx Class
2
3
3
3
Maximum heating
operating pressure
bar
3
3
3
3
Minimum pressure for
standard operation
bar
0,25-0,45
0,25-0,45
0,25-0,45
0,25-0,45
Maximum temperature
allowed
°C
90
90
90
90
Boiler water temp.
selection range (±3°C)
°C
40/80
40/80
40/80
40/80
Electrical power supply
Volt-Hz
230-50
230-50
230-50
230-50
Pump head available
to the system
mbar
227
227
227
227
at a flow rate of
l/h
1.000
1.000
1.000
1.000
Maximum electric
power consumption
W
89
115
131
163
Pump electrical
output (1.000 l/h)
W
75
75
75
75
Electrical protection
rating
IP
X5D
X5D
X5D
X5D
Expansion vessel
l
8
8
8
10
Expansion vessel
pre-load
bar
1
1
1
1
Maximum DHW
operating pressure
bar
6
6
6
6
Minimum DHW
operating pressure
bar
0,15
0,15
0,15
0,15
TECHNICAL DATA