START KI - KIS
18
DESCRIPTION
Methane gas (G20)
Butane (G30)
Propane (G31)
Lower Wobbe index (at 15°C-1013 mbar)
MJ/m
3
S
45,67
80,58
70,69
Net Calorific Value
MJ/m
3
S
34,02
116,09
88
Supply minimum pressure
mbar (mm H
2
O)
13,5 (137,7)
START 28 KI
Supply nominal pressure (II2H3+)
mbar (mm H
2
O)
20 (203,9)
28 - 30 (285,5 - 305,9)
37 (377,3)
Burner: number of nozzles
n°
14
14
14
diameter of nozzles
ø mm
1,30
0,78
0,78
CH maximum gas capacity
Sm
3
/h
3,37
kg/h
2,51
2,48
DHW maximum gas capacity
Sm
3
/h
3,37
kg/h
2,51
2,48
CH minimum gas capacity
Sm
3
/h
1,48
kg/h
1,10
1,09
DHW minimum gas capacity
Sm
3
/h
0,92
kg/h
0,69
0,68
CH maximum pressure
(mbar)
12,70
27,00
35,20
(mm H
2
O)
129,50
275,32
358,94
DHW maximum pressure
(mbar)
12,70
27,00
35,20
(mm H
2
O)
129,50
275,32
358,94
CH minimum pressure
(mbar)
2,60
5,50
7,10
(mm H
2
O)
26,51
56,08
72,40
DHW minimum pressure
(mbar)
1,00
2,30
2,90
(mm H
2
O)
10,20
23,45
29,57
START 24 KIS
Supply nominal pressure (II2H3+)
mbar (mm H
2
O)
20 (203,9)
28 - 30 (285,5 - 305,9)
37 (377,3)
Supply nominal pressure (II2H3B/P)
mbar (mm H
2
O)
20 (203,9)
30 (305,9)
30 (305,9)
Burner: number of nozzles
n°
11
11
11
diameter of nozzles
ø mm
1,35
0,78
0,78
CH maximum gas capacity
Sm
3
/h
2,73
kg/h
2,03
2,00
DHW maximum gas capacity
Sm
3
/h
2,73
kg/h
2,03
2,00
CH minimum gas capacity
Sm
3
/h
0,94
kg/h
0,70
0,69
DHW minimum gas capacity
Sm
3
/h
0,94
kg/h
0,70
0,69
CH maximum pressure
(mbar)
11,80
27,80
35,80
(mm H
2
O)
120,33
283,48
365,06
DHW maximum pressure
(mbar)
11,80
27,80
35,80
(mm H
2
O)
120,33
283,48
365,06
CH minimum pressure
(mbar)
1,50
3,30
4,30
(mm H
2
O)
15,30
33,65
43,85
DHW minimum pressure
(mbar)
1,50
3,30
4,30
(mm H
2
O)
15,30
33,65
43,85
MULTIGAS TABLE
*
KI model:
Pipe diameter 130 mm - length 0.5 m. - check performed in heating mode with water temperature 80°C-60°C
KIS model:
Checked carried out with concentric pipe ø 60-100 - length 0,85m - water temperature 80°C-60°C - flue gas flange of suitable
diameter installed
DESCRIPTION
START 28 KI
START 24 KIS
START 28 KIS
START 35 KIS
Quantity of hot
water with ∆t 25°C
l/min
16,5
13,7
16,3
20,0
Quantity of hot
water with ∆t 30°C
l/min
13,7
11,4
13,6
16,7
Quantity of hot
water with ∆t 35°C
l/min
11,8
9,8
11,6
14,3
Domestic hot water
temperature selection
range (±3°C)
°C
37-60
37-60
37-60
37-60
Minimum DHW
flow rate
l/min
2
2
2
2
Flow rate limiter
l/min
12
10
12
15