TECHNICAL ASSISTANCE SERVICE
68
Fault with DHW safety valve
(installed by heating engineer).
- Check valve setting and
efficiency.
Check DHW circuit pressure.
- Check central heating circuit
pressure.
Fault with DHW expansion vessel
(installed by heating engineer).
- Check the efficiency of the
expansion vessel.
The DHW safety valve
(installed by heating engineer)
keeps opening .
The supply pressure is too high.
- Fit a pressure reducer.
The flow rate is too high.
- Fit a flow reducer.
- Check and clean.
Lime scale and/or sludge in
storage cylinder.
- Check functioning of DHW
circuit pump.
- Check settings of control
thermostats.
- Check the positioning of sensors.
- Check boiler operating
temperature.
Reduced supply of
domestic hot water .
Pump seized.
Bad electrical connections.
- Check the pump and the
connections.
No heat request from boiler
controller.
- Check controller, sensors and
connections.
The central heating or DHW
pump is not working .
- Check the circuit pressure.
- Check pressure reducer
functioning.
- Check efficiency of safety valves.
Central heating circuit pressure.
Fault with DHW expansion vessel
(installed by heating engineer).
Central heating safety valves
trip frequently .
- Check the efficiency of the
expansion vessel.
CAUSE
CORRECTIVE ACTION
FAULT