TECHNICAL DATA
2.1
TECHNICAL DATA
2.2
OVERALL DIMENSIONS
2.3
WORKING FIELD
(2 nozzles in operation)
TYPE
616 M
Thermal power - Output
171/342 – 684 kW – 15/30 – 60 kg/h
Fuel
Oil with max. viscosity at 50° C 50 mm
2
/s
(7° E)
for oil up to
500 mm
2
/s (65° E) with kit
Electrical supply
Three-phase,
230 V
±
10%
~
50Hz
without neutral
400 V
±
10%
~
50Hz
with neutral
Motor
3.4 A / 230V – 2 A / 400V
Ignition transformer
Primary 2 A – Secondary 2 x 6.5 kV – 35 mA
Heaters
4.2 kW
Absorbed electrical power
5.5 kW
Pump
110 kg/h at 20 bar
For long - head version
.
*
Apply the extensions provided as accessories for the burner withdrawing.
Burner
Boiler plate
D2684
D2686
Thermal power
When the burner operates with only one nozzle, the pressurization conditions are improved and no problems
arise. Minimal fuel capacity with one only nozzle: 15 kg/h - 171 kW.
Pres
sur
e
in
c
o
mbus
tion
ch
amber
–
mba
r
kg/h
kW
D2685