22
For all other possible errors
please contact your supplier.
6.0 m
alfUncTions
WARNING
Do not work on the electrical components.
Only qualified personnel may perform this
work under certain conditions.
• No main voltage, check the fuses
• Main switch is set to 0/Off.
• Error in the slider control (if used).
See the corresponding user manual.
The extraction unit
won´t start
1
• One or two pre-fuses may have jumped.
Replace all 3 fuses. Set the main switch to
0 / Off, open the control cabinet and put
the motor protection switch back into
operation by pressing the black (1) button
* (after the switch has cooled). Then close
the switch box and set the main switch to
1/On. Restart the extraction unit. If the mo-
tor protection switch is triggered again,
contact your supplier.
*See page 10
Thermal failure
2
• Possible clogging of the pipes or
suction hose (always use a dust
mask when removing the block-
age!)
• Overloaded waste container. In
the case of an overloaded waste
container, chips can collect bet-
ween the filter hoses and can thus
influence the air flow. In this case,
the chips must be removed by
hand from the extraction unit (al-
ways use a dust mask when perfor-
ming this work!)
3
Reduced suction
• The waste bag is torn.
• The waste container has not been slid far
enough under the extraction unit.
• The rubber seal on the bottom of the ex-
traction unit is damaged.
4
The plastic waste bag is pulled
into the extraction unit
• One of the filter hoses is loose or
torn. Switch off the extraction unit
immediately and may only be swit-
ched on again when the filter hose
has been repaired or replaced (al-
ways use a dust mask when perfor-
ming this work!).
Note: Only use undamaged original filter
hoses!
5
Dust is escaping from
the return air opening
m
alfunctIons