background image

Use 

22 

 

Rieber GmbH & Co. KG 

 

 

6.3.6 

Messages due to exceeded usage times  

 

 

If the usage time is exceeded:  

 

The red usage time LED lights up. 

 

A continuous acoustic tone is emitted. 

 

The text shown on the display indicates the necessary measure. 

 

The time intervals for cleaning the high-performance grease separators are no 
more than 12 operating hours.  

Clean grease filters 

 

 Risk of fire

 

Clean the high-performance grease separators and reinsert them correctly 
with the other filter components.  

 

Replace filter mat if necessary.

 

 

The time intervals for replacing the Rieber active carbon filters are maximum 
500 operating hours. Only use the filter type specified in the display. 

Replace Rieber active carbon filters 

 

Replace the Rieber active carbon filters in the technical compartment.  

 

 

 

 

6.3.7 

Reset usage times, display operating hours 

 

 

Reset the usage time counters to 

0

 

 

Carry out the maintenance work correctly as indicated in the display. Only 
then should you reset the message. To do this:  

 

Still in off mode, press the TURBO and RESET buttons simultaneously for at 
least 10 seconds.  

▌ 

The counters are set to 

0

’ 

counter status. 

 

Display operating hours 

 

Press the TURBO button and hold it pressed for at least 10 seconds. 

 

▌ 

The total number of operating hours is shown in the display. This 
is the time during which the fan control is switched on. The display 
cannot be reset. 

 

 

 

Summary of Contents for varithek acs 1100 d3

Page 1: ...uard acs 1100 d3 attachment 2x varithek with attachment acs 600 ec 1x varithek Example variants acs varithek air cleaning system acs Observe the operating instructions Translation of the Original Operating Instructions DOWNLOAD USER MANUAL QR code on type plate EN ...

Page 2: ... 3 Technical data 14 5 Unloading from the pallet first commissioning 16 6 Use 17 6 1 Information on safe use 17 6 2 Ensure undisturbed extraction of steam and vapour 18 6 3 Electronic fan control 19 7 Ceaning maintenance and care 23 7 1 Safety information relating to cleaning maintenance and care 23 7 2 Cleaning agents for stainless steel 23 7 3 Choose the correct cleaning method 23 7 4 List of ac...

Page 3: ...including maintenance instructions customer drawing etc Page 6 Online version of these operating instructions Cleaning agents for stainless steel Choose the correct cleaning method Declaration of conformity Spare parts and necessary instructions www rieber de Select Customer Service at the top of the display bar In addition Do you wish to have the operating instructions in another language www rie...

Page 4: ...safety instructions The signal words DANGER WARNING CAUTION classify the degree of risk of bodily injury in an actual situation You can avoid injury by complying with the behavioural rules provided The warning triangle symbol indicates a General Danger DANGER indicates imminent danger Failure to follow these warnings will result in serious bodily injury or even death WARNING indicates a potentiall...

Page 5: ...king grilling cooking wok cooking and frying The relevant operating instructions must be observed The intended use includes compliance with the technical data Prevent any predictable misuse and abuse Modification of the appliance by the operator for example the filter combinations is not permitted Risks due to falling loose objects such as lids cooking utensils cutlery Do not use the appliance as ...

Page 6: ...Fleece Plasma Active carbon filter Flexible HEPA In addition to the Basic or Advanced combination for occasional more intensive cooking and if fat is used For frying and steaming strong smelling food light smoke production Grease Fleece Plasma HEPA Active carbon filter Advance For frying and steaming with more fat stronger smoke production Grease Fleece Electrostatic Active carbon filter Profi For...

Page 7: ...ust make sure that all personnel working with the appliance have read and understood this guide In addition the operator must train the personnel and inform them of the hazards involved at regular intervals The operator must provide the personnel with the necessary protective equipment and make sure that they wear it In addition the operator must ensure that the appliance is always in a perfect te...

Page 8: ...ion of the situation 3 4 1 Risks due to transport of mobile appliance Numerous hazards such as crushing can arise when transporting this heavy product acs varithek appliances may only be moved manually Machine aided transport e g using fork lift trucks or lift trucks is not permissible There is a risk of injury and the appliance could be damaged Remove accessories and transport them separately Dis...

Page 9: ...parator The technical compartment is monitored by a safety switch pressure switch If the pressure deviates in the technical compartment for example when the cover is open all components are electrically isolated or shut down The appliance remains energised Main switch operating lamp operating light digital control Circuit breaker s 3 5 Instructions on behaviour in an emergency First aid for respir...

Page 10: ...ple acs 1100 d3 2x varithek 1 4 swivel castors including 2 swivel castors with parking brakes on the operator side 2 Electrical connection with cable and plug 3 Main switch and operating light Electronic fan control 4 Power connections for cooking units CEE 400 V and Schuko 230 V 5 Cover with 1x quick release 6 Extraction areas 3 sided extraction of steam and vapour 7 Sneeze guard attachment inclu...

Page 11: ...00 ec 1x varithek 6 Extraction areas 6 1 Air supply area from radial fan 6 2 Extraction area 1 sided extraction of steam and vapours 9 Splash guard 3 sided from CNS 1 4301 removable without the use of tools 10 Cutting board made of PE in place and locked The cutting board can be removed for cleaning ...

Page 12: ...trays There is a uniform type of grease drip tray Any residual grease particles collect in the grease drip trays 3 Fleece filter mat including holder Particles and suspended matter are filtered out of the air The exhaust air exits downwards through the active carbon filter Active carbon filter for absorbing odours and pollutants Substances captured by adsorption accumulate in the carbon Substances...

Page 13: ...left via the air blowing jet and on the right with suction of the air the Push and Pull principle 1 High performance grease separator Grease and steam are separated 2 Grease drip trays There is a uniform type of grease drip tray Any residual grease particles collect in the grease drip trays 3 Fleece filter mat including holder Particles and suspended matter are filtered out of the air The exhaust ...

Page 14: ...DE 0100 540 2012 06 Permissible ambient temperature from 5 C to 40 C 3 sided splash guard 3 sided splash guard made of CNS 1 4301 Can be removed without the use of tools acs with attachment Delivery plate shelf made of 4 mm CNS CNS light strip with integrated LED lighting Guest side sneeze guard safety glass made of VSG Front sneeze guard glass removable for cleaning Air capacity in accordance wit...

Page 15: ...guard 1300 mm attachment Placement niche L x W x H approx 810 x 660 x 260 mm Usable depth 220 mm 1210 x 660 x 260 mm Usable depth 220 mm Weight approx 145 kg 165 kg 4 3 3 Concerning appliance type ec acs 600 ec 1x varithek acs 1000 ec 2x varithek acs 1100 ec attachment 2x varithek Permissible loading maximum 60 kg maximum 100 kg External dimensions L x W x H approx 600 x 760 x 900 mm 1002 mm splas...

Page 16: ...tted ATTENTION Do not unload from the pallet using a fork lift truck as this could cause substantial damage Lift deposit a heavy load evenly with your knees bent and your upper body straight and upright Your feet should be at least hip width apart and your abdominal muscles braced Breathe out Do not twist your spine Example Ensure that there are no protective foils on the inside or outside of the ...

Page 17: ...king devices Do not flambée For the deep fryer use an insertion mask that prevents slipping in the system module Only use one deep fryer on the appliance as otherwise the extraction and circulating air cleaning system may be overloaded and odours may develop Example Quickly exchangeable varithek cooking modules Highly efficient thanks to perfect heat transfer with thermoplates User tip Only use co...

Page 18: ...ne sided extraction type ec Place cooking units with higher odour emissions during cooking and roasting on the right hand side as the extraction effect is more intensive here Ensure that the parts of the upper extraction area are completely assembled Ensure that the cutting board option is in position Type d3 CORRECT INCORRECT Type ec CORRECT INCORRECT User tip If the temperature is set too high f...

Page 19: ...d is in position Briefly removing the cutting board for cleaning will not interrupt the extraction 6 3 Electronic fan control 6 3 1 Operating panel Button 1 ON OFF 2 RESET 3 TURBO 4 Decrease ventilation intensity levels 4 to 1 5 Increase ventilation intensity levels 1 to 4 Display 6 LED display 7 LED fan fault red alarm 8 LED plasma fault red alarm 9 LED filter usage time exceeded red alarm 10 LED...

Page 20: ...tch off The display goes out The display is black User tip We recommend letting the extraction system run on for another 10 minutes at the end of the cooking process so that the vapour caused by the residual heat cannot disperse into the environment 6 3 3 Adjust ventilation intensity Adjust intensity levels 1 to 4 Press the PLUS button 5 to increase the level Press the MINUS button 4 to decrease t...

Page 21: ...several faults are present at the same time the fault with the highest priority is displayed The fault display replaces the fan operating state display Faults 7 8 9 remain illuminated until they have been eliminated and acknowledged Check for possible errors Is the technical compartment closed Are the filters in the technical compartment free from objects Are the Rieber active carbon filters corre...

Page 22: ...filters are maximum 500 operating hours Only use the filter type specified in the display Replace Rieber active carbon filters Replace the Rieber active carbon filters in the technical compartment 6 3 7 Reset usage times display operating hours Reset the usage time counters to 0 Carry out the maintenance work correctly as indicated in the display Only then should you reset the message To do this S...

Page 23: ... into the electrical system and cause a short circuit Do not expose to spray water Wipe electrical parts with a moist cloth only and dry the surface using a dry cloth Have electrical appliances inspected by a qualified electrician at least every 6 months 1 Fire risks Risk of fire Risk of fire due to damaged missing or incorrectly mounted filter components Only use with original filter components a...

Page 24: ...ration Replace active carbon filter Page 31 Every 4 to 6 months HEPA filter Electrostatic filter 2 See footnotes below Every 6 months Have electrical equipment inspected by a qualified electrician in accordance with DGUV regulation 3 Also have the residual current operated device inspected Page 23 After at least 3000 hours of operation For version with plasma technology Clean plasma generator Page...

Page 25: ...ped in at the top Note on removable U profile on the attachment Example d3 The markings arrow and push lettering are engraved on the surface To remove the U profile push it to the left in the direction of the arrow and remove it on the operator side To insert the U profile position the profiles on top of each other and then push the U profile to the right into the operating position ...

Page 26: ...aning maintenance and care 26 Rieber GmbH Co KG Example ec Ensure exact positioning during assembly ensure 2x fixing with pin Example ec For cleaning open the cover on the left by activating the closures ...

Page 27: ...ide filter unit after use daily Before carrying out repairs maintenance and cleaning activities disconnect the appliance from the power supply by unplugging the mains plug 7 6 2 Notes on assembly and disassembly Example d3 The illustration shows appliance type d3 as an example Appliance type ec only has a filter unit on the right 1 sided edge extraction ...

Page 28: ... drip trays 3 Fleece filter mat including holder There is a uniform type of filter fleece Particles and solid matter are filtered out of the air in the dry filter After opening the quick release fastener of the cover part positions 1 to 3 can be pulled out at the front then inspected and cleaned Assembly and disassembly may occur in any order There is a left and a right high performance grease sep...

Page 29: ...il is spilt the technical compartment must be thoroughly cleaned immediately Grease particles are deposited on the fleece filter mat If grease stains have formed and the fleece feels greasy you should replace it immediately Dispose of the used fleece filter mat as domestic waste Order no 61 98 05 96 ...

Page 30: ...the filter Clean the grease drip trays with grease soluble cleaning agent Rinse thoroughly and then dry completely Clean the holder for the fleece filter mat if necessary Ensure that the parts are completely dry and undamaged prior to assembly Secure the position of the front cover with the turn lock fastener Page 27 Pay attention to completely assembled installed parts such as the cutting board o...

Page 31: ...wing etc 7 7 1 Inspect and clean technical compartment replace filter Opening and closing Example d3 Opening angle around 70 to 90 simply remove or insert the cover Cleaning the radial fan Example d3 Unplug the plug of the radial fan Remove the assembly together with the radial fan by pulling it out forwards Clean the soiled surfaces of the radial fan with a warm cloth slightly dampened with a mil...

Page 32: ... not place any objects in the technical compartment Only operate with a dry active carbon filter Dispose of the active carbon filter with respect for the environment as domestic waste Order no 37 25 22 08 active carbon filter 409x270x32 mm Note on version with Flexible HEPA option HEPA filters are only suitable for filter combinations without an electrostatic filter Place the HEPA filter above the...

Page 33: ... variant filter technology used including maintenance instructions customer drawing etc WARNING Health risks respiratory disorders All interference with the plasma generator is forbidden Do not place any objects in the technical compartment Detail Failure to clean the electrode on the plasma generator can cause unpleasant odours when using the appliance due to malfunction Clean the electrode on th...

Page 34: ...e remedy Sockets do not work Automatic circuit breaker s triggered Check status Qualified electrician Customer Service spare parts IMPORTANT Customer service needs information about the type and number of your appliance If you have a fault you cannot remedy yourself please get in touch with your Rieber partner or Rieber central customer services 8 2 Disposing of your product Electrical appliances ...

Page 35: ... apply for all warranty claims made against the manufacturer For instance any repairs and or overhaul during the warranty period may only be performed by the manufacturer s service department at Rieber otherwise any arising claims may be voided Please contact the manufacturer s service department at Rieber The following wear parts are not included in the warranty Castor castor with parking brake A...