![Rieber ACS 1600 O3 Digital Operating Instructions Manual Download Page 62](http://html.mh-extra.com/html/rieber/acs-1600-o3-digital/acs-1600-o3-digital_operating-instructions-manual_1459136062.webp)
Troubleshooting
–
What now?
62
Rieber GmbH & Co. KG
Fault
Possible cause
Possible remedy
Extraction and circulating-air
cleaning malfunction
➢
WARNING
Check status
seqq.
#
Operating staff
Electrode on plasma
generator soiled
➢
Clean
Page 54
#
Operating staff
Chilling compartment
iced up
Inadequately pre-chilled food
introduced
➢
Defrost and clean compartment
#
Operating staff
Sealing frame missing
➢
Insert sealing frame
Loss of refrigerant
➢
WARNING
Check condition.
#
Refrigeration expert
Appliance very
difficult to move
Castors locked with brake
➢
Release lock
#
Operating staff
Customer service, spare parts
IMPORTANT
Customer service needs information about the type and number of your appliance.
➢
If you have a fault you cannot remedy yourself, please get in touch with your Rieber partner or
Rieber central customer services.
9.2
Disposing of your product
Your appliance is made of high-quality material which can be reused / recycled. For
disposal, disconnect the appliance from mains supply. Unplug the mains plug. Cut off the
cable directly at the casing. Dispose of this appliance properly via your local disposal
facility.
WARNING
Persons with limited sensory and mental ability might get locked in.
►
When disposing of the unit, destroy the door lock.