RIDGID WD0635 Operator'S Manual Download Page 3

3

• Use only extension cords that are rated

for outdoor use. Extension cords in
poor condition or that are too small in
wire size can pose fire and shock
hazards. To reduce the risk of these
hazards when using an extension cord,
be sure it is in good condition and that
the connection does not come into
contact with liquid. To keep power loss
to a minimum, use the following table
to choose the minimum wire size
extension cord.

as it should, has missing parts, has
been dropped, damaged, left outdoors,
or dropped into water, return it to an
Authorized Service Center.

• Do not pull or carry by cord, use cord

as handle, close a door on cord, or pull
cord around sharp edges or corners.
Do not run Vac over cord. Keep cord
away from heated surfaces.

• Do not handle plug, switch, or the Vac

with wet hands.

• Do not put any object into ventilation

openings. Do not vacuum with any
ventilation openings blocked; keep free
of dust, lint, hair or anything that may
reduce air flow.

• Keep hair, loose clothing, fingers, and

all parts of body away from openings
and moving parts.

• To reduce the risk of falls, use extra

care when cleaning on stairs.

• To reduce the risk of back injury or

falls, do not lift a Vac that is heavy with
liquid or debris.  Partially empty the
Vac by scooping or draining liquid to
make it comfortable to lift. 

• To reduce the risk of personal injury or

damage to Vac, use only Ridgid
recommended accessories.

• When using as a blower:

- Direct air discharge only at work

area.

- Do not direct air at bystanders.
- Keep children away when blowing.
- Do not use blower for any job except

blowing dirt and debris.

- Do not use as a sprayer.
- Wear safety eyewear.

• To reduce the risk of eye injury, wear

safety eyewear. The operation of any
utility Vac or blower can result in
foreign objects being blown into the
eyes, which can result in severe eye
damage.

• This Wet/Dry Vac is double-insulated,

eliminating the need for a separate
grounding system. Use only identical
replacement parts. Read the
instructions for Servicing Double-
Insulated Wet/Dry Vacs before
servicing.

Extension Cord Length Gauge A.W.G.

0-50 Ft.

14

50-100 Ft.

12

Observe the following warnings that
appear on the motor housing of your Vac:

WARNING: For your own safety,

read and understand operator’s
manual. Do not run unattended. Do
not pick up hot ashes, coals, toxic,
flammable or other hazardous
materials. Do not use around
explosive liquids or vapors.

WARNING: To reduce the risk of
electric shock - do not expose to
rain - store indoors.

DOUBLE INSULATED
GROUNDING NOT REQUIRED.
WHEN SERVICING USE ONLY
IDENTICAL REPLACEMENT PARTS.

!

SAVE THIS MANUAL

CAUTION: 

• To reduce the risk of hearing damage,

wear ear protectors when using for
extended hours using it in a noisy area.

• For dusty operations, wear dust mask.

NOTE: Static shocks are common

in

dry areas or when the relative humidity of
the air is low.  Vacuuming fine debris with
your Vac can deposit static charge on the
hose or on the Vac. The best remedy to
reduce the frequency of static shocks in
your home or when using this Vac is to
add moisture to the air with a humidifier.

!

SP6662 ES.qxd  3/16/07  9:08 AM  Page 3

Summary of Contents for WD0635

Page 1: ...US AT CALL 1 800 4 RIDGID 1 800 474 3443 OR www ridgidvacs com OPERATOR S MANUAL SAVE THIS MANUAL FOR FUTURE REFERENCE WARNING To reduce the risk of injury the user must read and understand the opera...

Page 2: ...lammable vapors or dust To reduce the risk of fire or explosion Do not vacuum or use near flammable or combustible liquids gases or explosive dusts such as gasoline or other fuels lighter fluid cleane...

Page 3: ...at work area Do not direct air at bystanders Keep children away when blowing Do not use blower for any job except blowing dirt and debris Do not use as a sprayer Wear safety eyewear To reduce the ris...

Page 4: ...n the dust drum upside down on the floor 2 Insert the caster feet into the bottom of drum as shown 4 places 3 Push on the caster foot until the foot is flush with bottom of the dust drum 4 Insert the...

Page 5: ...steps are complete and you have read and understood the safety and operation instructions Do not operate vac with any parts damaged or missing Filter Cage Filter Nut Lever Filter Nut Filter Plate Filt...

Page 6: ...n Power Cord Handle Hose Utility Nozzle Casters Caster Feet w Accessory Storage Dust Drum Cord Wrap Area Flexible Locking Tab Pulled Out Flexible Locking Tab Drum Vacuum Port Powerhead Push Down and P...

Page 7: ...ith ANSI Z87 1 or in Canada CSA Z94 3 before starting operation Safety Eyewear are available at many local retail stores To reduce the risk of electric shock this appliance has a polarized plug one bl...

Page 8: ...commend that the filter be removed If the filter is not removed it will become saturated and misting may appear in the exhaust 3 When the liquid in the drum reaches a predetermined level the float mec...

Page 9: ...n it Even a small hole can cause a lot of dust to come out of your vac Replace it immediately Filter Removal To remove the filter for cleaning or replacement unscrew the filter nut from the filter cag...

Page 10: ...t solution stand for 20 minutes carefully swishing every few minutes making sure to wet all inside surfaces of the drum 3 Empty drum after 20 minutes Rinse with water until bleach smell is gone Allow...

Page 11: ...11 Notes SP6662 ES qxd 3 16 07 9 08 AM Page 11...

Page 12: ...extreme care and knowledge of the system and should be done only by qualified service personnel Replacement parts for a double insulated Wet Dry Vac must be identical to the parts they replace Your d...

Page 13: ...6 U S Gallons Wet Dry Vac Model Number WD06350 RIDGID parts are available on line at www ridgidparts com 1 10 7 8 9 12 11 3 2 4 5 6 13 SP6662 ES qxd 3 16 07 9 08 AM Page 13...

Page 14: ...l wear and tear are not covered by this warranty RIDGE TOOL shall not be responsible for any incidental or consequential damages How local law relates to the warranty Some states do not allow the excl...

Page 15: ...S LLAMANDO AL 1 800 4 RIDGID 1 800 474 3443 O CONECT NDOSE A www ridgidvacs com MANUAL DEL OPERADOR GUARDE ESTE MANUAL PARA REFERENCIA FUTURA ADVERTENCIA Para reducir el riesgo de lesiones el usuario...

Page 16: ...el polvo Para reducir el riesgo de incendio o explosi n No recoja con la aspiradora l quidos o gases inflamables o combustibles o polvos explosivos como gasolina u otros combustibles l quido encended...

Page 17: ...s Esta aspiradora para mojado seco tiene aislamiento doble lo cual elimina la necesidad de un sistema independiente de conexi n a tierra Utilice nicamente piezas de repuesto id nticas Lea las instrucc...

Page 18: ...correo electr nico conect ndose a info ridgidvacs com si alguna pieza est da ada o falta Desempaquetado y comprobaci n del contenido de la caja de cart n 1 Ponga el tambor para polvo en posici n inve...

Page 19: ...o con las ranuras del anillo central de la tapa 5 Empuje sobre la jaula del filtro hasta que las leng etas se acoplen a presi n en las ranuras para lograr un encaje Filter Cage Filter Nut Lever Filter...

Page 20: ...esi n en su sitio Para quitar la manguera de la aspiradora oprima el bot n de liberaci n que est en el ensamblaje de la manguera y tire de la manguera hasta sacarla de la entrada de la aspiradora de l...

Page 21: ...sion Wand 2 Utility Nozzle 1 Deslice los tubos extensores y los accesorios sobre los postes de las ruedecillas para almacenarlos 2 Para quitar los tubos y los accesorios g relos ligeramente y tire de...

Page 22: ...esto suceda apague la aspiradora desenchufe el cord n de energ a y vac e el tambor 4 Despu s de usar la aspiradora para recoger l quidos se debe secar el filtro para evitar posible moho y da os al fi...

Page 23: ...Filtro NOTA Este filtro est hecho de papel de alta calidad dise ado para detener part culas de polvo muy peque as El filtro se puede usar para recoger material seco o peque as cantidades de l quido M...

Page 24: ...jor aspecto posible de la aspiradora para mojado seco limpie su exterior con un pa o humedecido con agua templada y un jab n suave Para limpiar el tambor 1 Vac e de residuos el tambor 2 Lave a fondo e...

Page 25: ...Notas 25 SP6662 ES qxd 3 16 07 9 08 AM Page 25...

Page 26: ...ora para mojado seco con aislamiento doble se proporcionan dos sistemas de aislamiento en vez de conexi n a tierra No se proporciona ning n medio de conexi n a tierra en un aparato electro dom stico c...

Page 27: ...a mojado seco de 6 galones EE UU N meros de modelo WD06350 Las piezas RIDGID se encuentran disponibles en l nea conect ndose a www ridgidparts com 1 10 7 8 9 12 11 3 2 4 5 6 27 SP6662 ES qxd 3 16 07 9...

Page 28: ...de ning n da o incidental ni emergente C mo se relaciona la ley local con la garant a Algunos estados no permiten la exclusi n o limitaci n de los da os incidentales o emergentes por lo que es posible...

Reviews: