CRITICAL STEP:

 It is recommended that a person at the call-to 

location confirms receiving the test phone call. Validate all calls 

before concluding that the system setup is finished.

ENTERING AND CHANGING PHONE NUMBERS

When programming phone numbers into the System, enter each 

phone number into the phone setup screens exactly as you 

would when making a personal phone call.  
Two phone number entry methods:
1.  As part of the Installation Setup procedure (follow the on 

     screen prompts) or,
2.  From the “Home Screen”, select “MENU”, enter the security 

     code (if prompted), then locate the “Phone Setup” option 

     and then press the button for “ENTER”.  
 

a. You can modify, delete, or verify within this selection.   

 

b. To delete any number, simply press “DEL” and it will  

      

    backspace as needed. 

 

c. To EDIT a number, re-enter the phone number and it 

 

    will overwrite the existing number.

PROPER PHONE NUMBER ENTRY

System can place local calls, long distance calls, and even 

international calls. The use of calling cards is not recommended 

for they are difficult to enter and can change without notice and 

result in a phone call never being made. 
Example:
 

*Local Number:  123-4567

 

*Long Distance:  1 (555) 123-4567

 

* International: Country code, followed by 1, then the 

 

phone number. For proper dialing instructions or 

 

further assistance, contact your service provider. 

 

Enter the phone number exactly as you would when    

 

dialing a call yourself.  If your local number requires the  

 

area code, enter as needed.

CREATING PAUSES WHEN ENTERING PHONE NUMBERS:

Some phone calls require accessing an outside telephone line 

from a digital system. Obtain the digit(s) necessary to access 

the outside line (dialing “9” to access an outside line is most 

common). A time delay may be required to let the system fully 

access the outside line and this is accomplished by entering 

two “stars” (**) after dialing the 9. 
The following examples use a “9” to access the outside phone 

line followed by a 2 second delay before the auto-dialer is 

initiated to place an automated phone call by the System:  

 

 

Local call:  9** then 123-4567

          

Long distance call:  9** then 1 (555) 123-4567

TIME DELAYS

  

 

** = 2 seconds, **** = 4 seconds, ****** = 6 seconds

All stars (*) must be entered in multiples of 2 or the system will 

not recognize them as actual time delays.

PHONE TEST

After entering all phone numbers, it is crucial that you test your 

System to verify that it can reach the call list phone numbers.

 

TESTING YOUR 12 VOLT ADVANCED NOTIFICATION SYSTEM 

PHONE NUMBERS

To test the System, do the following:
1.  Make sure the System is powered up, phone line is 

     connected, and the "Home Screen" has no error messages. 

     To make sure all timers and errors are cleared from the 

     system memory, press and hold the "RESET" button for 

     a minimum of 3-5 seconds. 
2.  Press the MENU button followed by the “Phone Setup” 

     option.  
3.  Scroll to the desired phone number, hit ENTER, then select 

     the TEST option.
The system will immediately dial the desired phone number. 

Upon answering, the unit will play the following message: “This 

is a test of the back-up system.” It will repeat this message for 

approximately “1” minute and then hang up. The display will 

prompt you asking if the test was successful, if Yes, it returns to 

the home screen. If “NO”, it will retest. 
4.  Repeat Steps 2 and 3 to test the remaining phone numbers.
The System does not provide any indication of call success; 

therefore, you must verify that the call was made successfully.

TESTING FOR A SPECIFIC ALARM CONDITION

To test for a specific alarm condition you will have to simulate 

that specific alarm condition and then verify if the alarm phone 

calls went through. In those scenarios, you must cancel the 

alarm call out sequence and correct the alarm condition by 

pressing and holding the RESET button for a minimum of 5 

seconds.

HOW THE SYSTEM WORKS WITH VOICE MAIL OR AN 

ANSWERING MACHINE

When it is necessary to connect an answering machine or voice 

mail device to the same phone line as the System, you can still 

use all the features of these devices, along with being able to 

check status and cancel an alarm call out of the System.

HOW THIS WORKS:

The System can answer incoming calls to check the system 

status. To do this, the ring count must be set to answer on 

either “5” or “10” rings (default setting is 10 rings, change this 

setting from the Main Menu>Set Ring Count).
Set your answering machine or voice mail to answer in fewer 

rings than the System. (For example, if the System is set to 

answer on 5 rings, set the answering machine/voice mail to 

answer in “4” or fewer rings.) Therefore, when a call comes into 

the location of the System, the answering machine/voice mail 

will respond first because it is set to answer in fewer rings than 

the System.

RING COUNT TIMER

The ring count timer works in the following way: when the first 

call comes in during an alarm event, the internal system timer 

starts counting down for “3” continuous minutes. If the System 

receives enough rings to answer (within “3” minutes), it will 

respond, and the ring counter will reset to “0” regardless if the 

three minutes have elapsed or not. Also, the timer will reset 

to “0” if no additional calls are received during a three minute 

period (multiple calls to the System within “3”minutes will not 

reset the ring timer).

CALLING THE 12 VOLT ADVANCED NOTIFICATION SYSTEM 

DURING AN ALARM EVENT

Example: 
1) The back-up system is set to answer in 5 rings (ring count 

setting).  
2) The answering machine/voice mail is set to answer in "4" 

rings or fewer.
To get the System to respond given the above example criteria, 

do the following:
1.  Call the phone number of the location where the 

     System is located, and let the phone ring “3” times 

     and then hang up. The internal 3-minute timer starts and 

 

The CANCEL key does not function when the 

 

System is in "test mode".

7

Ridge Tool Company

Model RSM3300 – Operating Instructions and Parts Manual

Summary of Contents for RSM3300

Page 1: ...l no entender y no seguir el contenido de este manual puede dar como resultado un choque eléctrico incendios y o lesiones graves AVERTISSEMENT LIRE COMPRENDRE ET SUIVRE TOUTES LES INSTRUCTIONS DANS CE MANUEL NE PAS JETER Ne pas comprendre et ne pas suivre les contenus de ce manuel peut avoir pour résultat un choc électrique de feux et ou de blessures personnelles graves WARNING READ UNDERSTAND AND...

Page 2: ...e Téléphonique 17 19 Fonctionnement 19 Soins et Entretien de la Batterie 19 Installation et Configuration du Systéme de Sécurité 20 Pièces de Rechange 21 Tableau de Dépannage 22 Carte de Rèfèrence Rapide à Découper 23 Garantie Couverture arrière Índice Instrucciones de Inicio Rápido 24 Descripción 26 Desembalaje 26 Pautas de Seguridad 26 Información General de Seguridad 26 Especificaciones 26 Cons...

Page 3: ...ck up pump 1 Switch with clamp 1 Last Auto Test MENU MUTE RESET 12 1 V System Armed Ready 100 Select the starting language and follow the on screen instructions to set up the controller Upon completion of controller setup restore AC power and test the main pump as described in the operation section of the manual Red Black Does not include 12 Volt DC deep cycle battery phone jack phone line pipe an...

Page 4: ...Notes Ridge Tool Company Model RSM3300 Operating Instructions and Parts Manual 2 ...

Page 5: ... instructions WILL result in bodily injury or death Electric shock hazard Disconnect power before servicing Apply a fixed lock or tag to prevent unexpected application of power Electric shock hazard DO NOT walk on wet floor until power is disconnected Use a licensed electrician to perform service in accordance with the National Electrical Code and all local codes CALIFORNIA PROPOSITION 65 This pro...

Page 6: ...e pump or check valve to be removed easily for servicing 8 Check valve is recommended for effective operation of system The remainder of the discharge pipe installation will vary depending on individual circumstances Using sound plumbing practices route the discharge pipe to an exterior wall by the shortest path Keep turns to a minimum because they reduce flow output of the pump The pipe that exit...

Page 7: ...red for permanent installation 9 Glue a 45º elbow to the short pipe on the Back Up DC Pump Glue a Y adapter to the short pipe on the existing pump as shown in illustration for Method 2 10 Glue a short piece of PVC pipe between the 45º elbow and the Y The remainder of the discharge pipe installation will vary depending on individual circumstances Using sound plumbing practices route the discharge p...

Page 8: ...ative terminal of the battery The display should be lit up at this time If connected improperly an alarm will sound until corrected 4 Plug the pump and float switch connectors into the 12 Volt Advanced Notification System The connections are marked See Step 6 in the Quick Start Guide 5 Follow the on screen instructions Test pump operation by filling the sump with water while the main pump is unplu...

Page 9: ...phone number hit ENTER then select the TEST option The system will immediately dial the desired phone number Upon answering the unit will play the following message This is a test of the back up system It will repeat this message for approximately 1 minute and then hang up The display will prompt you asking if the test was successful if Yes it returns to the home screen If NO it will retest 4 Repe...

Page 10: ...3 Call the number a second time within three minutes The System keeps track of all the rings from the previous calls accumulates them until the total ring count matches its ring count number 5 or 10 and then it will answer Listen to the alarm message 4 Press the number 1 key followed by the pound key anytime during the message to cancel the alarm call out Hang up the phone OPERATION 1 After instal...

Page 11: ... of devices that may be connected to a telephone line Excessive REN s on a telephone line may result in the devices not ringing in response to an incoming call In most but not all areas the sum of RENs should not exceed five 5 0 To be certain of the number of devices that may be connected to a line as determined by the total REN s contact your local telephone company The REN for this product is li...

Page 12: ...one number at alarm location let ring three 3 times hang up 2 Make a second call to the System within 3 minutes the System will answer on the second ring 3 rings 2 rings System answers on fifth 5th ring 3 Listen to the alarm messages 4 Press the 1 key then pound key anytime during the message to acknowledge and cancel the alarm 5 Note if answering service answers before the System does start over ...

Page 13: ...red with a lower discharge height 4 Check battery and replace if low or defective 5 Check to make sure the back up pump is not air locked Locate the vent hole inspect and clear the hole using a pipe cleaner Pump Cycles Too Frequently 1 Check valve problem 1 Check to make sure check valves installed between primary pump discharge and back up sump pump are functioning properly CONTROLLER Flood Emerg...

Page 14: ...ntrôleur terminée rétablir l alimentation c a et vérifier la pompe principale conformément à la description donnée dans la section Fonctionnement de ce manuel Rouge Noir N inclut pas la batterie à décharge poussée de 12 volts c c la prise téléphonique la ligne téléphonique le tuyau et les raccords nécessaires Affichage principal Affichage au démarrage Interrupteur à flotteur Sécurité Pompe c c Req...

Page 15: ...Remarques 13 Ridge Tool Company Model RSM3300 Operating Instructions and Parts Manual ...

Page 16: ...ntretien conformément au Code national de l électricité et aux codes locaux PROPOSITION 65 DE L ÉTAT DE CALIFORNIE Ce produit ou son cordon d alimentation PEUT contenir des produits chimiques dont le plomb qui sont reconnus par l État de Californie comme cancérigènes et à l origine d anomalies congénitales ou d autres problèmes de l appareil reproductif Se laver les mains après toute manipulation ...

Page 17: ... maximum dans la mesure où qu ils réduisent le débit de sortie de la pompe Le tuyau qui sort de la structure de l édifice doit être installé sur une pente afin que l eau ne gèle pas à l intérieur du tuyau Lors de l installation du tuyau de décharge indépendant percer à travers le mur extérieur à l aide d un équipement de perçage adapté Sceller le trou afin d empêcher l eau d entrer L installation ...

Page 18: ...u court de la pompe de secours c c Coller un adaptateur en Y au tuyau court de la pompe existante comme indiqué sur l illustration de la méthode 2 10 Coller une section courte de tuyau en PVC entre le coude de 45º et le Y Le reste de l installation du tuyau de décharge variera en fonction des circonstances individuelles Utiliser des pratiques de plomberie sûres pour acheminer le tuyau de décharge ...

Page 19: ...e alarme se déclenche jusqu à ce que le problème soit corrigé 4 Brancher les connecteurs de la pompe et de l interrupteur à flotteur sur le système de notification préalable de 12 volts Les connexions sont estampillées Voir l étape 6 du Guide de démarrage rapide 5 Suivre les instructions à l écran Tester le fonctionnement de la pompe en remplissant le puisard d eau alors que la pompe principale es...

Page 20: ...t toutes les erreurs sont effacées de la mémoire du système maintenir le bouton RESET réinitialisation enfoncé pendant au moins 3 à 5 secondes 2 Appuyer sur le bouton MENU suivi de l option Phone Setup installation du système téléphonique 3 Faire défiler la liste jusqu au numéro désiré appuyer sur ENTER saisir puis sélectionner l option TEST Le système composera immédiatement le numéro de téléphon...

Page 21: ... sortant suivre les étapes suivantes ÉTAPES À SUIVRE 1 Appeler le système le numéro de téléphone du site de l alarme 2 Laisser le téléphone sonner le nombre de sonneries souhaité avant que le répondeur ou la messagerie vocale reliés sur la même ligne puisse répondre puis raccrocher 3 Appeler le numéro une seconde fois dans les 3 minutes qui suivent le système mémorise le nombre de sonneries de l a...

Page 22: ... préalable n est pas possible la compagnie de téléphone avisera le client dès que possible En outre vous serez informé de votre droit à déposer une plainte auprès de la FCC si vous le jugez nécessaire La compagnie de téléphone peut apporter des modifications à ses installations équipements opérations et procédures qui pourraient affecter le fonctionnement de l équipement Dans ce cas de figure la c...

Page 23: ...e la batterie sujet à caution APPELTÉLÉPHONIQUE ALARME SONORE SIGNALDU SYSTÈME DE SÉCURITÉ Inverser la polarité Figure 6 Tableau des alertes de notification 21 Ridge Tool Company Modèle RSM3300 Manuel de pièces et mode d emploi Nº de référence Description Nº de commande Quantité 1 Assemblage couvercle et contrôleur 60161 001 1 2 Interrupteur à flotteur avec pince 60158 001 1 3 Transformateur 60159...

Page 24: ...fonctionne pas 1 Connexions non sécurisées 2 Batterie faible ou défectueuse 3 Interrupteur à flotteur coincé 4 Fusible défectueux ou grillé 1 Vérifier toutes les connexions 2 Vérifier la batterie et la remplacer si elle est faible ou défectueuse 3 S assurer que rien n entrave le fonctionnement de l interrupteur 4 Vérifier le fusible interne situé à l intérieur du couvercle du contrôleur Sortir le ...

Page 25: ...o de téléphone du site de l alarme laisser sonner trois 3 sonneries puis raccrocher 2 Appeler le système une seconde fois dans les 3 minutes qui suivent le système répondra au bout e deux sonneries 3 2 sonneries le système répond au bout de 5e sonneries 3 Écouter le ou les messages d alarme 4 Appuyer sur la touche 1 puis sur la touche carré à tout moment durant la lecture du message pour accuser r...

Page 26: ... System Armed Ready 100 Seleccione el idioma de inicio y siga las instrucciones de la pantalla para configurar el controlador Una vez completada la configuración del controlador restablezca la energía CA y pruebe la bomba principal tal como se describe en la sección de operación del manual Rojo Negro No incluye Batería de ciclo profundo de 12 voltios CC enchufe hembra del teléfono línea telefónica...

Page 27: ...Notas 25 Ridge Tool Company Modelo RSM3300 Manual de instrucciones de funcionamiento y piezas de repuesto ...

Page 28: ...te producto o su cable de corriente PUEDEN contener químicos incluido plomo que son conocidos por el Estado de California como causantes de cáncer y defectos de nacimiento u otros daños reproductivos Lávese las manos después de manipularlo Riesgo de explosión Prohibido fumar y encender llamas La recarga de la batería y las conexiones DEBEN ser realizadas en un área bien ventilada Requisitos de sum...

Page 29: ...s circunstancias individuales Dirija la tubería de descarga hacia una pared exterior por el camino más corto siguiendo las técnicas de instalación sanitaria más adecuadas Mantenga al mínimo los acodamientos porque reducen la salida de flujo de la bomba La tubería que sale de la estructura de la construcción debe estar en declive para que el agua no se congele en la tubería Cuando instale la tuberí...

Page 30: ... bomba 9 Pegue un codo de 45º al tubo corto en la bomba de respaldo de CC Pegue un adaptador en Y al tubo corto en la bomba existente como se muestra en la ilustración del Método 2 10 Pegue una pieza corta de tubo de PVC entre el codo de 45º y la Y El resto de la instalación de la tubería de descarga variará dependiendo de las circunstancias individuales Dirija la tubería de descarga hacia una par...

Page 31: ...rrecta sonará una alarma hasta que se corrija 4 Enchufe la bomba y los conectores del interruptor de flotador en el sistema avanzado de notificación de 12 voltios Las conexiones están marcadas Consulte el Paso 6 de la guía de inicio rápido 5 Siga las instrucciones de la pantalla Verifique el funcionamiento de la bomba llenando el sumidero con agua y manteniendo desconectada la bomba primaria Si la...

Page 32: ... la Home Screen pantalla de inicio no tenga mensajes de error 2 Presione el botón MENU menú seguido de la opción Phone Setup configuración del teléfono 3 Desplácese hacia el número de teléfono deseado presione ENTER ingresar y luego seleccione la opción TEST prueba El sistema marcará inmediatamente el número de teléfono deseado Una vez que se responde la unidad reproducirá el siguiente mensaje Est...

Page 33: ...a de llamadas de alarma haga lo siguiente PASOS QUE DEBE REALIZAR 1 Realice la llamada al Sistema número de teléfono en el lugar de la alarma 2 Deje sonar el teléfono la cantidad de veces deseadas antes de que la otra máquina contestadora correo de voz de la línea pueda responder Cuelgue el teléfono 3 Llame al número por segunda vez en un plazo de tres minutos el Sistema lleva un registro de todos...

Page 34: ...DE LA RED TELEFÓNICA Si este Sistema causa daño a la red telefónica la compañía telefónica le notificará con anticipación que puede ser necesaria la suspensión temporal del servicio Pero si el aviso con anticipación no es práctico la compañía telefónica notificará al cliente tan pronto como sea posible Además se le notificará sobre su derecho a presentar una queja ante la FCC si cree que es necesa...

Page 35: ...ba no funciona 1 Batería defectuosa 2 El impulsor está bloqueado 1 Verifique la batería y reemplácela si el flujo es bajo o defectuoso 2 Desconecte la bomba retire la rejilla y revise para ver si el impulsor puede girar libremente Si el impulsor está bloqueado retire los 7 tornillos en la parte inferior de la bomba para liberar la caja que cubre el impulsor Retire la obstrucción Vuelva a armar la ...

Page 36: ... la compañía de servicios públicos 2 Prepare una batería de repuesto Cambie la batería 1 La batería tiene poca carga 2 La batería tiene más de 5 años 3 Se descargó y se dejó sin carga por más de 3 días 4 Los ciclos de carga exceden el máximo 1 Cambie la batería tan pronto como sea posible 2 Cambie la batería 3 Cambie la batería 4 Cambie la batería Cambie inspeccione el flotador 1 El flotador está ...

Page 37: ...aga una llamada al Sistema número de teléfono de la ubicación de la alarma deje sonar 3 tres veces cuelgue 2 Realice una segunda llamada al Sistema en 3 minutos el Sistema responderá en el segundo repique 3 repiques 2 repiques el Sistema responde en el quinto 5o repique 3 Escuche los mensajes de alarma 4 Presione la tecla 1 y luego la tecla numeral en cualquier momento durante el mensaje para acus...

Page 38: ...Notes Remarques Notas 36 Ridge Tool Company Modelo RSM3300 Manual de instrucciones de funcionamiento y piezas de repuesto ...

Page 39: ...Notes Remarques Notas 37 Ridge Tool Company Modelo RSM3300 Manual de instrucciones de funcionamiento y piezas de repuesto ...

Page 40: ...por una persona que no esté autorizada por el centro de servicio para reparar bombas de agua de la marca RIDGID o la incapacidad de funcionar de acuerdo con las instrucciones escritas de la bomba de agua RIDGID WAYNE WATER SYSTEMS NO PROPORCIONA NINGUNA GARANTÍA REPRESENTACIÓN NI PROMESA EXPRESA SOBRE LA CALIDAD O EL FUNCIONAMIENTO DE SUS BOMBAS DE AGUA EXCEPTO POR AQUELLAS QUE SE MENCIONAN ESPECÍ...

Reviews: