10 - English
MAINTENANCE
NOTE:
When the brushes wear down to a predetermined
level, the tool automatically switches off, ruling out the
possibility of damage to the armature.
Reassemble using new brush assemblies. Make sure
curvature of brush matches curvature of motor and that
brush moves freely in brush tube.
Replace brush cap and tighten securely. Do not
overtighten.
BRUSH REPLACEMENT
See Figure 10, page 12.
This product has externally accessible brush assemblies
that should be periodically checked for wear.
Unplug the tool.
With a flat head screwdriver, remove the brush caps. The
brush assembly is spring loaded and will pop out when
you remove the brush cap.
Remove the brush assembly (brush and spring). Check
for wear. Replace both brushes when either has less than
1/4 in. length of carbon remaining. Do not replace one
side without replacing the other.
NOTE: ILLUSTRATIONS START ON PAGE 11
AFTER FRENCH AND SPANISH LANGUAGE SECTIONS.
This product has a 90-Day Satisfaction Guarantee Policy,
as well as a Three-year Limited Warranty. For Warranty and Policy details,
please go to www.RIDGID.com or call (toll free) 1-866-539-1710.
Summary of Contents for R7135
Page 31: ...13 MANTENIMIENTO ...