figure 4
figure 5
figure 6
figure 7
figure 8
Press
+
to enter the system setting menu showed in figure 4,
press
or
to enter the sub-menu.
Settings Sub-menu:
System language
is
is set to English by default
. You can also set Simplified
Chinese, French, Germany and Russian language;
Take OK
is
set to ON by default
, when you quickly call out a data group, there
will be a prompt as shown in figure 3, if you set OFF for this option, the settings will
be edited directly when call out a data group;
Take Out
is set to OFF by default
, when call out a data group, it will keep the
previous output status, when set it ON, it will output directly when call out a data
group.
Boot Power
is set to OFF by default
, when boot the device the output is cut off,
when set it on, it will automatically turn on the output after booting.
Boot Logo
is set to ON by default
, when boot the device, it will show the boot
logo first, then enter the main interface, when set it OFF, it will enter the main
interface directly.
Buzzer
is set to ON by default
,it will show
on the top, and you can hear the
beep when press the button. When set it OFF, it will show
, there will not be beep
when press the button.
Backlight
is set to level 4 by default, it can be set between level 0-5.
Update Rate
is set to Low by default, you can set it low/mid/high, it is the fresh
rate of the real output voltage and current.
Max Power
is set to 380W by default, you can set it between 1-380W, it is the
max output power. The max output is default voltage priority mode, when the setting
voltage*setting current is higher than the max power, the device will automatically
decrease the output current setting value. When used together with low power
Summary of Contents for RD6006P