Figure 2-3
Filling module in mixing tank
No.
Description
No.
Description
1
Fresh water
inlet
3
Shut-off valve (with plastic rotary knob for manual
operation)
2
Float
4
Water inlet of mixing tank
2.3.3
Pressure module with filter
The pressure module guides the irrigation water to the dosing module with the
measurement module. The pressure module is equipped with a pressure regulator
that enables the pressure before the venturis (see section "Dosing module" on
page 16) to be set to 2.2 bars. The pressure after the venturis is always 0 bars. The
screen filter in the pressure module prevents the venturis from clogging.
FertiMiX
13