SH-P1 Training
44
Slide 44
Replacing the Controller – 1
Print out the SMC first.
When you replace the controller, remove the 2
NVRAMs from the old controller and install them
on the new one.
Make sure the NVRAMs are oriented correctly.
The notches should be oriented as shown in the
illustration on the next slide.
The 45 ppm and 50 ppm machines have different
controller boards. Don't mix them up!
Don't change the DIP switches.
Refer to the FSM for the detailed controller
replacement procedure.
No additional notes.