43
English
Appendices
If ceiling mounted, please use caution when opening the lamp access panel. It is recom
-
mended to wear safety glasses if changing the bulb when ceiling mounted. Caution must
be used to prevent any loose parts from falling out of projector.
Firmly install the lamp assembly as well as its cover.
If failing to install the lamp bulb smoothly, take it down and try again. If excessive force is
used when installing the bulb, the connectors may be damaged.
Do not disassemble any screws other than those specified.
1. Turn off the power in accordance with the procedures specified in the “Turning off the
Projector”. Unplug power cord from the power socket on the wall. Wait for at least one
hour until it is confirmed that the lamp components and its surroundings have been
completely cooled.
2. Unscrew the fixing screws of lamp components cover plate with cross head screwdriver,
and then open the lamp components cover plate.
● Slowly pull out the lamp components cover plate according to the direction of arrow.
3. Unscrew two fixing screws of lamp components with cross head screwdriver until the
screws are completely loose. Hold the handle, and gently pull up the lamp components
from the projector.
4. Insert the unused lamp components in the correct direction. Tighten the two fixing
screws of lamp components with cross head screwdriver.
5. Close the lamp components cover plate and tighten its fixing screws with cross head
screwdriver.
Reset the lamp usage time
After replacing the lamp components, reset usage time in [Clear the lamp usage time]
menu.
Lamp Replacement Procedure
Lamp component
cover plate
Handle
Fixing screws of lamp
component
Fixing screws of lamp com-
ponent cover plate
Caution:
If the lamp
should break, handle with
care to avoid injury due to
broken pieces and contact
your sales representative
for repair service.