Paper Cooling
There two sets of exhaust fans and two sets of cooling fans in the buffer pass unit. These fans turn on in 0.1
seconds interval as follows below after the mainframe has turned on or received a printer job or copy job.
• Upper exhaust fans [A] > lower exhaust fans [B] > upper cooling fans [C] > lower cooling fans [D]
The lower cooling fans [D] draw air in the buffer pass unit from the outside, and then move air [E] to the
upper area along with the outer of the paper path. This makes the outer of the paper path cooler. Finally
air around the upper area is expelled to the outside by the upper exhaust fans [A].
Also the upper cooling fans [C] draw air in the buffer pass unit from the outside, and then move air [F] to
the center area along with the inner of the paper path. This makes the inner of the paper path cooler. Finally
air around the center area is expelled to the outside by the lower exhaust fans [B].
Two sides of the paper path guide remove heat from a sheet of paper while a sheet of paper is being
transported. As a result, a sheet of paper from the exit of this unit is properly cooled.
The fan operation time after the initializing or job end can be adjusted by SP1940-008 (adjustable from
0 to 60 minutes/ default: 10 minutes).
Paper Cooling
37
2
Summary of Contents for M379
Page 1: ...Buffer Pass Unit Machine Code M379 Service Manual 31 March 2009 Subject to change...
Page 2: ......
Page 11: ...Drive Layout 34 Paper Path 36 Paper Cooling 37 9...
Page 12: ...10...
Page 16: ...2 Operation Panel x 2 x 1 1 Replacement and Adjustment 14 1...
Page 25: ...4 C2 handle A B x 1 5 Front inner cover A x 6 Sensors and Switches 23 1...
Page 33: ...2 Interface cable A Electronic Components 31 1...
Page 34: ...1 Replacement and Adjustment 32 1...
Page 35: ...2 Details Overview Components Layout 33 2...
Page 40: ...2 Details 38 2...