Adjustment
Side Registration Adjustment
Normally the side registration of the image can be adjusted with SP1002-004 to -006 (Side-to-Side
Registration – Tray 1, 2, 3). When the punch hole positions are not aligned from a particular feed
station, adjust the side registration by changing the tray cover position for the tray, as described below.
Then adjust the side registration of the image with the SP1002.
1. Pull out the tray.
2. Change the screw positions [A] at both the right and left sides as shown.
• Adjustment range: 0 ± 2.0 mm adjustment step: 0.5 mm/step
Double Feed Problem from LCIT
If double feed occurs several times when paper is fed from an LCIT (Tray 1, 2 or 3), try to change the
upper limit of the paper stack in the LCIT tray. Changing the upper limit of the paper stack in the LCIT
tray can improve paper separation for the paper stack in the LCIT tray.
1. Remove the paper feed unit of the LCIT unit (page 13 "Paper Feed Units").
2. Loosen the screw on the paper lift sensor bracket [A].
3. Move the bracket 0.5 mm in the arrow direction as shown above.