31 October 2001
MAIN MENU NO.7: MEMORY CLEAR
5-13
Service
Tables
5.8 MAIN MENU NO.7: MEMORY CLEAR
5.8.1 SP TABLE
No.
Menu Items
Default
Settings
7-1 Factory settings clear
No
No / Clr (
☛
5.8.3)
7-2 All settings clear
No
No / Clr
7-3 Total counter clear
No
No / Clr
7-4 Jam/Error data clear
No
No / Clr
5.8.2 SP7: HOW TO CLEAR
1. Using the number “1” key or the scroll keys, select “Clr”.
2. Press the Enter key.
3. When the clear is completed, ring the beeper.
5.8.3 SP7-1: FACTORY SETTINGS CLEAR
This resets all SP settings except for the following SP numbers.
•
SP2-20: Destination settings
•
SP3-01: Present time
•
SP6-All: Adjustments
Summary of Contents for Gestetner 5428C
Page 1: ...SERVICE MANUAL Machine code C238...
Page 140: ...POINT TO POINT DIAGRAM 31 October 2001 7 2 Location Map C238S500 WMF...
Page 141: ...31 October 2001 POINT TO POINT DIAGRAM 7 3 P to P Section A C238S501 WMF...
Page 142: ...POINT TO POINT DIAGRAM 31 October 2001 7 4 Section B C238S502 WMF...
Page 143: ...31 October 2001 POINT TO POINT DIAGRAM 7 5 P to P Section C C238S503 WMF...
Page 144: ...POINT TO POINT DIAGRAM 31 October 2001 7 6 Section D C238S504 WMF...
Page 145: ...31 October 2001 POINT TO POINT DIAGRAM 7 7 P to P Section E C238S505 WMF...
Page 146: ...POINT TO POINT DIAGRAM 31 October 2001 7 8 Section F C238S506 WMF...
Page 147: ...31 October 2001 POINT TO POINT DIAGRAM 7 9 P to P Section G C238S507 WMF...
Page 148: ...POINT TO POINT DIAGRAM 31 October 2001 7 10 Section H C238S508 WMF...