SP Mode Tables
SM Appendix
4-11
D096
Appe
ndix:
SP
Mode
Ta
b
le
s
2927*
ID Sensor Control
2927 1
[
0 = No
/ 1 = Yes]
Selects whether the ID sensor is or is not used for toner density control. This
value should normally be left at "1". If the value is "0", dirty background may
occur after long periods of non-use.
2928
Toner End Clear
2928 1
Clears the toner end condition without adding new toner. The following are
cleared:
Toner end indicator (goes out)
Toner near-end counter
Toner near-end level
This function should generally not be used. If you clear the toner end
condition without adding new toner, there is a risk that the drum may
eventually begin to attract carrier after many more copies are made and toner
runs out. This attracted carrier may damage the drum.
2929*
Vref Limits
Adjust the upper or lower Vref limit.
2929 1 Upper
[0.50 to 3.50 /
3.20
/ 0.01V/step]
DFU
2929 2 Lower
[0.50 to 3.50 /
0.70
/ 0.01V/step]
DFU
2994*
ID Sensor Detection
Temperature
[30 to 90 /
30
/ 1
°
C/step]
2994 1
While the machine is recovering from an energy saver mode, or while the
machine starts, the BICU ignores the ID-sensor signals if the fusing
temperature is at the specified value or higher.
Summary of Contents for D096
Page 1: ...D096 SERVICE MANUAL 005627MIU ...
Page 2: ......
Page 3: ...D096 SERVICE MANUAL ...
Page 4: ......
Page 5: ...D096 SERVICE MANUAL 005627MIU ...
Page 6: ......
Page 8: ......
Page 10: ......
Page 12: ......
Page 18: ......
Page 20: ......
Page 24: ......
Page 25: ...PRODUCT INFORMATION REVISION HISTORY Page Date Added Updated New None ...
Page 26: ......
Page 30: ...Overview D096 1 4 SM 1 4 OVERVIEW 1 4 1 COMPONENT LAYOUT ...
Page 34: ......
Page 35: ...INSTALLATION REVISION HISTORY Page Date Added Updated New None ...
Page 36: ......
Page 55: ...PREVENTIVE MAINTENANCE REVISION HISTORY Page Date Added Updated New None ...
Page 56: ......
Page 60: ......
Page 61: ...REPLACEMENT AND ADJUSTMENT REVISION HISTORY Page Date Added Updated New None ...
Page 62: ......
Page 110: ...Fusing D096 4 48 SM 4 9 6 THERMOSTAT 1 Hot roller See above 2 Thermostat A x 2 for each ...
Page 127: ...SERVICE TABLES REVISION HISTORY Page Date Added Updated New None ...
Page 128: ......
Page 153: ...TROUBLESHOOTING REVISION HISTORY Page Date Added Updated New None ...
Page 154: ......
Page 161: ...ENERGY SAVING REVISION HISTORY Page Date Added Updated New None ...
Page 162: ......
Page 167: ...D096 SERVICE MANUAL APPENDICES ...
Page 168: ......
Page 170: ......
Page 171: ...APPENDIX SPECIFICATIONS REVISION HISTORY Page Date Added Updated New None ...
Page 172: ......
Page 186: ......
Page 187: ...APPENDIX PREVENTIVE MAINTENANCE REVISION HISTORY Page Date Added Updated New None ...
Page 188: ......
Page 193: ...APPENDIX TROUBLESHOOTING GUIDE REVISION HISTORY Page Date Added Updated New None ...
Page 194: ......
Page 207: ...APPENDIX SP MODE TABLES REVISION HISTORY Page Date Added Updated New None ...
Page 208: ......
Page 244: ......
Page 246: ......