Slide 83
Fusing Unit
The procedure to reassemble the fusing unit is a
bit complicated.
The stripper pawls must be put in the correct
position before you can reassemble the fusing
unit.
Stripper pawls (red circles) and stripper pawl
heads (red arrows) must be set as shown below.
7. Replacements and Adjustments
More on Reassembling the Fusing Unit
The most important thing to note when you reassemble the fusing unit, is the
position of the 4 stripper pawls.
The stripper pawls must be put back to their original position when you
reassemble the fusing unit.
The machine will still work if the stripper pawls are not put back in their
correct positions.
However the print quality will be severely affected.
There is a procedure to do this.
1. Remove the stripper pawls from the stripper pawl slots.
2. Put the top part of the fusing unit and the bottom part of the fusing unit
together again.
3. Set the stripper pawls into the stripper pawls holder slots and snap
them into the slots.
4. Make sure the stripper pawl heads sit as they are shown in the slide.
5. Finally, reassemble the rest of the fusing unit.