SERVICE CALL CONDITIONS
1 October, 1999
7-6
SC541: Fusing temperature warm-up error
Definition: [A]
The fusing temperature detected by the thermistor was below 13
°
C for 10
seconds
Possible causes:
•
Fusing thermistor defective or out of position
•
Fusing lamp open
•
Fusing thermofuse open
•
Power supply board defective
•
Poor connection of the fusing unit
SC542: Fusing temperature warm-up error
Definition: [A]
The fusing temperature does not reach the fusing standby temperature within 40
seconds after the main switch is turned on.
Possible causes:
•
Fusing thermistor defective or out of position
•
Fusing lamp open
•
Fusing thermofuse open
•
Power supply board defective
•
Poor connection of the fusing unit
SC543: Fusing overheat error
Definition: [A]
A fusing temperature of over 230
°
C is detected for 1 second by the fusing
thermistor.
Possible causes:
•
Fusing thermistor defective
•
Power supply board defective
SC544: Fusing low temperature error
Definition: [A]
A fusing temperature of lower 100
°
C is detected for 1 second by the fusing
thermistor.
Possible causes:
•
Fusing thermistor defective
•
Power supply board defective
•
Poor connection of the fusing unit