NOTE: To ensure grounding, tighten the screws for the ground wire until the
spring washers [A] are flattened.
12. Secure the grounding wire [B] (1 screw with spring washer) to the inside
of the table.
13. Run the roll feeder harness [C] and roll feeder heater harness [D] through
the holes in the table rear cover (right [E] and left [F])
14. Connect the roll feeder harness to the copier main board {2 connectors
[G] and 1 grounding wire [H] (1 screw with spring washer)}.
15. Connect the roll feeder heater harness connector [I] to the copier ac drive
board connector.
16. Install the harness covers [J] (1 screw each).
17. Reattach all the covers and manual feed table excluding the roll feeder
right cover.
[F]
[E]
[B]
[A]
[D]
[C]
[H]
[J]
[G]
[I]
[A]
INSTALLATION PROCEDURE
31 October 1994
14