北京锐志天宏科技股份有限公司
Beijing RichAuto S&T Co., Ltd.
67
Forging ahead, create future together!
Abnormally running when processing or the actual file is different from theoretical file
1)
The system program disorder.
2)
Too much external interference lead the controller cannot work normally. Re-adjust overall
circuit. (The wires of weak current and strong current should be separately binding, the
inverter and other components should be separated connected each GND of themselves).
3)
There is something wrong while converting the file format and the program appears illegal
characters or system unrecognized codes. Recommended to use third party simulation
software to review the program paths.
Start automatic tool setting, the tool does not stop after touching C.A.D (Tool sensor).
1)
The cutter signal cable connects X5 maybe broken circuit.
2)
The "GND" signal port on the interface board hasn’t been connected with spindle housing or
poor connection.
3)
Go to “MACHINE SETUP”-“Input Confi” to confirm if X4 is enabled.
Coordinate value changes on screen, but the machine does not move
1)
If it is one axis not moving, it maybe wiring problem. Change another normal terminal to this
axis wiring terminal, if it moves properly indicating the rear parts of motor driver have no
problem. Check if there is something wrong with interface board or 50-pin cable. If it is still
not moving, it is necessary to detect the corresponding drive and motor.
2)
If all axes are not moving, firstly, check if there are problems in the 50-pin cable and
interface board,; secondly, if the interface board and 50-pin cable are normal, then user
should check the power supply of the motor drivers.
3)
If debugged all above parts, but the machine still not move, then the mechanical parts
should be checked.
It is normal to the move from one position to another position, but when return from that
position to the original position is not normal
Mechanical assembly problem, guide screw may be not installed well.