G. Connection And Testing:
For a quick connection and performance check,
please follow these guidelines.
G-1. Unpack and inspect the power inverter, check to see
that the power switch in the OFF position.
G-2. Connect the DC NEGATIVE cable to the Negative
(NEG-) terminal on the battery. Next, connect the
BLACK cable to the negative terminal on the inverter.
The connection to the negative terminal of the
inverter should be the last connection made. A spark
when making this final connection is normal.
G-3. Before proceeding further, carefully check that cable
you have just connected from the negative terminal of
inverter to the Negative output terminal of power
source.
G-4. Connect the RED cable from the positive terminal of
inverter to the positive terminal of the power source.
Make secure connection.
WARNING!
Make sure tall the DC connections are tight (torque
to 9-10 ft-lbs, 11.7-13 Nm). Loose connections
will overheat and could result in potential hazard.
WARNING!
Reverse polarity connection will blow a fuse in
Inverter and may permanently damage the inverter.
Damage caused by reverse polarity connection is
not covered by our warranty.