15
4.4
Specifications
End Load Capacity:
100% full scale at 5,000 lb
80% full scale at 10,000 lb
Warranty:
RoughDeck QC-X weldment five years, load cells two
years, all other components one year
Electrical Grounding
For systems where the scale is connected to a 120 VAC circuit, the instrument must be directly connected to an earth ground with a ground interface
cable of no more than 3
resistance throughout its length.
Load Cell Excitation
Rated Excitation: 10 VDC Maximum Excitation: 15 VDC
Nominal Scale Height
5 K–10 K lb (2500–5000 kg) models: 4.625" (117.48 mm)