Product Specifications

9

5.0

Product Specifications 

Impedance:

Ranger 1:  700 ohms nominal

Ranger 3 & 5: 350 ohms nominal

Output Ranges:

Ranger 1:  0 to 3 mV/V continuously variable

Ranger 3 & 5: -0.5, 0, 0.5, 1.0, 1.5, 2.0, 2.5, 3.0, and 4.5 mV/V

Vernier (Ranger 5 only):

Fine:

-0.02 to +0.5 mV/V of selected range

Medium:

-0.05 to +1.5 mV/V of selected range

Course:

-0.12 to +3.0 mV/V of selected range

Accuracy (Ranger 3 & 5):

+/-0.02% of selected range

Zero Offset (Ranger 3 & 5):

Ranger 1:  +0.005 mV/V Max

Ranger 3 & 5: +0.0005 mV/V Max

Normal Operating Temp:

14°F to 104°F (-10

C to + 40

C)

Temperature Coefficient:

Ranger 1:       100 ppm/ 

C

Ranger 3 & 5:   5 ppm/ 

C

Excitation Voltage:

15 VDC/AC Max

Unit Size:

3.5

W x 4.5

L x 2.2

D

Weight:

0.55 lb (Ranger 5)

Enclosure:

Flame retardant ABS plastic

Ranger 7

Load Impedance: 

Three settings by toggle switch. 

X0.5 =700 ohms

X1 = 350 ohms (1standard load cell)

X4= 87.5 ohms (4 load cell platform)

Output Range: 

0-3mV/V in .01mV/V steps (300 precision fixed steps)

Switchable Vernier: 

Two Ranges

Range 1 is equal to the 0.5mV/V switch plus 0 -0.5mV/V. 

Range 2 is equal to the 0.5mV/V switch plus the 0.1mV/V switch plus 0-0.1mV/V. Enabled by 

pressing the switch.

Switchable Offset: 

Off or switch setting ±25μV/V. Enabled by pressing the switch.

Accuracy: 

±0.01% + 1μV of selected range

Zero Setting: 

Position 

Zero

 returns the output to zero regardless of the switch settings. Offset setting remains 

constant (if enabled).

Zero Offset: 

±0.0005 mV/V

Initial Zero Offset:

 ±2μV

Normal Operating Temp: 

14°F to 104°F (-10°C to +40°C), accuracy specified at 23°C ±5°C

Temperature Coefficient: 

5ppm/°C

Excitation Voltage: 

3.5V to 12V unipolar. ±1.75 to ±6 Bipolar

LED Annunciators: 

EXC+ – normal Excitation Polarity.

EXC– – reverse Excitation Polarity. Both are on with AC Excitation.

OFFSET ON – the offset pot is enabled.

0.5mV/V – the variable pot is enabled with a range of 0 to 0.5mV/V plus the 0.5mV/V Rotary Switch 
setting.

0.1mV/V – the variable pot is enabled with a range of 0 to 0.1mV/V plus the 0.5mV/V and 0.1mV/V 
switch settings.

Binding Posts: 

Type 2758 (by Low Thermal Electronics Inc.) precision gold plated low thermal EMF 5-way binding 
posts for highest accuracy. Standard banana jacks at 0.75

 Pitch, or up to 14 AWG wire.

Summary of Contents for Ranger 1

Page 1: ...105354 Rev A Ranger Series Load Cell Simulators Operation Manual...

Page 2: ......

Page 3: ...riable Setting 7 4 0 Troubleshooting With a Simulator 8 5 0 Product Specifications 9 Limited Warranty 10 Rice Lake Weighing Systems All rights reserved Printed in the United States of America Specific...

Page 4: ...ii Ranger Series Operation Manual Rice Lake continually offers web based video training on a growing selection of product related topics at no cost Visit www ricelake com webinars...

Page 5: ...re 1 1 Ranger 1 3 and 5 Simulators Features Ranger 1 Bridge impedance of 700 ohms 10 turn continuously variable output from 0 to 3 mV V Ranger 3 Bridge impedance of 350 ohms Nine calibrated outputs ei...

Page 6: ...or 2 Ranger Series Operation Guide Figure 1 2 Ranger 7 Simulator Ranger 7 Load Impedance Three settings by toggle switch X0 5 700 X1 350 1 standard Load Cell X4 87 5 4 Load Cell Platform Output Range...

Page 7: ...hould not exceed 15 volts DC or AC RMS Higher voltages will degrade the accuracy and possibly damage your simulator When using the Ranger 5 simulator for testing stability or drift or when recalibrati...

Page 8: ...oltage value from step 2 Example 2 99825 x 9 9875 29 945 mV This is the full scale millivolt output of the scale at the total load cell capacity individual load cell capacity x the number of load cell...

Page 9: ...librated Pre Calibrating an Indicator Using a Simulator Ranger 3 and 5 Only For this example we will pre calibrate an indicator that will be connected to a single load cell application The cell capaci...

Page 10: ...n this setting This allows an easy way to check AZM settings as well as quick return to zero for time testing Example Switch one is set to 2mV V switch two is set to 0 0 and switch three is set to 00...

Page 11: ...function 3 3 Variable Press the Variable switch to enable disable the function There are two ranges of variable mV V 3 3 1 Coarse Control Range The range is 0 to 500 V V 0 to 0 5mV V plus the setting...

Page 12: ...s substituted for the load cells and the value displayed for the zero and one of the other calibrated settings i e 1 mV V are recorded later recalibration or repair can be greatly simplified by direct...

Page 13: ...equal to the 0 5mV V switch plus 0 0 5mV V Range 2 is equal to the 0 5mV V switch plus the 0 1mV V switch plus 0 0 1mV V Enabled by pressing the switch Switchable Offset Off or switch setting 25 V V...

Page 14: ...caused by accident misuse neglect alteration improper installation improper repair or improper testing RLWS shall be the sole judge of all alleged non conformities Such equipment has not been modified...

Page 15: ......

Page 16: ...8 USA U S 800 472 6703 Canada Mexico 800 321 6703 International 715 234 9171 Europe 31 0 88 2349171 www ricelake com www ricelake mx www ricelake eu www ricelake co in m ricelake com Rice Lake Weighin...

Reviews: