IS6V2 Battery
© Rice Lake Weighing Systems
●
All Rights Reserved
3
Operating Times
All estimated operating times are based on a fully charged battery. A fully charged battery is one that has been charged until the
charger pilot lamp has switched from amber color to off (signifying 95% charged) at which point the charger switches to a float
charge mode and the LED turns off.
To keep the battery at full capacity, it is recommended to leave the battery connected to the charger, in float charge
mode, until ready to use. The battery can remain on the charger in float charge mode indefinitely without damaging
the battery. See IS6V2 Battery Charging Instruction sheet (PN 194893) for instructions on charging the battery.
To preserve battery life, disconnect the battery when not in use. Even if the indicator is turned off, the indicator will
still draw a small amount of power while connected.
IS6V2 Battery Charging
Charging a dead battery takes a minimum of 10 hours. The recommended initial battery charging time is 14 hours.
1. Disconnect battery cable from indicator.
2. Remove battery pack from indicator tilt stand and take to non-hazardous area.
3. Remove the lockout device and battery cable from the battery.
Figure 4. Remove Lockout Device
4. Charge the battery.
Re-charge batteries in a non-hazardous location.
Load Cell Size
Quantity of Cells
Operating Time
350
load cell
1
80 - 95 hours
4
60 - 80 hours
700
load cell
1
85 - 100 hours
4
70 - 90 hours
Table 1. Estimated Battery Operating Times
Note
Note
CAUTION