background image

IS6V2 Battery

© Rice Lake Weighing Systems 

 All Rights Reserved

3

Operating Times

All estimated operating times are based on a fully charged battery. A fully charged battery is one that has been charged until the 

charger pilot lamp has switched from amber color to off (signifying 95% charged) at which point the charger switches to a float 

charge mode and the LED turns off.

To keep the battery at full capacity, it is recommended to leave the battery connected to the charger, in float charge 

mode, until ready to use. The battery can remain on the charger in float charge mode indefinitely without damaging 

the battery. See IS6V2 Battery Charging Instruction sheet (PN 194893) for instructions on charging the battery.

To preserve battery life, disconnect the battery when not in use. Even if the indicator is turned off, the indicator will 

still draw a small amount of power while connected. 

IS6V2 Battery Charging

Charging a dead battery takes a minimum of 10 hours. The recommended initial battery charging time is 14 hours.

1. Disconnect battery cable from indicator.
2. Remove battery pack from indicator tilt stand and take to non-hazardous area.
3. Remove the lockout device and battery cable from the battery.

Figure 4. Remove Lockout Device

4. Charge the battery.

  Re-charge batteries in a non-hazardous location.

Load Cell Size

Quantity of Cells

Operating Time

350

 load cell

1

80 - 95 hours

4

60 - 80 hours

700

 load cell

1

85 - 100 hours

4

70 - 90 hours

Table 1.  Estimated Battery Operating Times