![Rice Lake IQ plus 210 Installation Manual Download Page 23](http://html1.mh-extra.com/html/rice-lake/iq-plus-210/iq-plus-210_installation-manual_1453897023.webp)
Configuration
©
Rice Lake Weighing Systems
●
All Rights Reserved
17
3.2.4 Serial Menu
Figure 3-9. Serial Menu
SERIAL Menu
Parameter
Choices
Description
BAUD
9600
1200
2400
4800
Baud rate. Selects the transmission speed for the serial port.
BITS
8NONE
7EVEN
7ODD
Selects number of data bits and parity of data transmitted from the serial port.
TERMIN
CR/LF
CR
Termination character. Selects termination character for data sent from the serial port.
ECHO
OFF
ON
This command enables or disables echoing of the serial commands sent to the indicator.
PRNFRQ
DEMAND
AUTO1
AUTO2
STREAM
Print frequency. Specifies when the indicator sends data to the serial port:
DEMAND:When a PRINT digital input is activated or the KPRINT EDP command received.
AUTO1:Output enabled by scale in motion; transmitted when scale returns to standstill.
AUTO2:Output enabled by scale at center of zero; transmitted when a positive scale weight is at standstill.
STREAM:Continuous output. See
for output format.
Weight data is sent to the serial port in displayed units except when other units are specified using one of the XGx
).
If DEMAND, AUTO1, or AUTO2, is selected for this parameter, serial output is formatted as follows:
wwwwwww
uu
GROSS
where
wwwwww
is a 7-digit weight field (leading zeroes suppressed, including decimal point and minus sign, if
required),
uu
is the units designator (lb, kg, oz, or G).
If pounds/ounces (LB/OZ) is specified as the primary units, the serial output is formatted as shown below:
xxx
lb
yyyy
oz GROSS
where
xxx
is the three-digit pounds weight (including minus sign, if required) followed by
lb
and a space; and
yyyy
is the four-digit ounce weight (including decimal point) followed by
oz
.
Table 3-5. Serial Menu Parameters
BITS
BAUD
9600
7ODD
7EVEN
8NONE
4800
2400
1200
XXXXXXX
XXXXXXX
VERS
DEFLT
DIG IN
SERIAL
CALIBR
CONFIG
FORMAT
PRNFRQ
DEMAND
AUTO1
AUTO2
STREAM
TERMIN
CR
CR/LF
ECHO
ON
OFF
Summary of Contents for IQ plus 210
Page 35: ......