Appendix
©
Rice Lake Weighing Systems
●
All Rights Reserved
27
6.3 Continuous Output (Stream) Format
Figure 6-1 shows the continuous output format sent to the IQ plus 210 EDP or printer port when the STREAM parameter
(SERIAL menu) is set to either EDP or PRN.
Figure 6-1. Continuous Output Data Format
6.4 Cable Specifications
6.5 Torque Specifications
Connector
Wire Gauge Range
Wire Strip Length
J1 and J2 (PN 153873)
16-28 AWG
0.276'' (7 mm)
J3 (PN 153883)
16-28 AWG
0.276'' (7 mm)
J13 (PN 181694)
16-24 AWG
0.394'' (10 mm)
DC Power (PN 15888)
12-24 AWG
0.276'' (7 mm)
Table 6-4. Recommended Wire Gauge Specifications
Cord Grip
Diameter Range
PG9 (PN 15626)
0.138 - 0.315'' (3.5 - 8 mm)
PG11 (PN 68600)
0.197 - 0.394'' (5 - 10 mm)
Table 6-5. Cord Grip Specifications
Connector
Torque
Around cables
22 in-lb
Cord grip to enclosure
33 in-lb
Table 6-6. Cord Grip Specifications
<TERM>
ASCII 02
(decimal)
Polarity:
<Space> = Positive
<–> = Negative
<^> = Overload
<]> = Underrange
Weight data: 7 digits, right-justified, with
decimal point, leading zero suppression.
Overload =
^^^^^^^
Underrange =
] ] ] ] ] ] ]
Display overflow =
OVERFL
L = pounds
K = kilogram
G = grams
O = ounces
<space> = lb/oz
G = Gross
Status:
<space> = valid
I = Invalid
M = In motion
O = Over/under range
<CR> <LF>
or <CR>
ASCII 13, 10
(decimal)
<STX> <POL> <wwwwwww> <UNIT> <G> <S>