Installation
©
Rice Lake Weighing Systems
●
All Rights Reserved
15
2.12 Junction Box Wiring
All TuffSeal® junction box models have been designed to connect and trim up to four load cells per board.
1. Route the load cell wires from the load cell through the load cell cable mounting clips and into the junction box.
Do not tighten the load cell cable mounting clips yet.
2. Push in and hold the quick-connect lever of the wire connectors with a small screwdriver.
3. Insert the wires into the appropriate wire openings for each load cell (
).
4. Release the screwdriver to allow the spring-loaded gate to close and lock the wire in place.
Do not cut load cell cables.
Figure 2-15. Junction Box Board
Table 2-1. Cable Color Coding
For junction box trimming, refer to TUFFSeal® Installation Manual (PN 184804).
Cable Code
Designated Color
+Excitation
Red
-Excitation
Black
+Signal
Green
-Signal
White
Shield
Bare
Note
IMPORTANT
JP4
PT4
PT3
JP3
JP2
PT1
1
EXP
PT2
JP1
1
CELL4
1
CELL1
1
CELL3
1
CELL2
1
IND
-EX
-SI
SHD
+SI
+EX
M
-SI
S2C
+SI
+EX
-EX
-SI
SHD
+SI
+EX
-EX
-SI
SHD
+SI
+EX
+SI
-SI
-EX
SHD
-EX
SHD
+EX
+SE
-SE
Load Cell 4
Load Cell 3
Load Cell 1
Load Cell 2
Note