![Rice Lake Dyna-Link 2 MSI-7300 Technical Manual Download Page 17](http://html1.mh-extra.com/html/rice-lake/dyna-link-2-msi-7300/dyna-link-2-msi-7300_technical-manual_1454008017.webp)
Setup
13
4.5 Total
For the accumulation of multiple weighments, the Total function uses the displayed load, so gross and net readings
can be added into the same total.
There are four modes of totalizing, a manual and three auto modes.
All modes require that the weight on the scale return below 0.5% (relative to full scale) of
Gross Zero
or
Net Zero
before the next weighment can be added. Applied weight must be
≥
1% of full scale above
Gross Zero
or
Net Zero
before it can be totaled.
Manual Total
Manual Total (
) adds a current weight to a previously accumulated value manually. To add weight to the total
it must be greater than 1% of capacity and not yet totaled. This assures that a weight on the scale is only added to
the total once.
Note
1. Program a
F-key
to
. See Section 4.2 on page 9.
2. With the weight to be added on the scale, press
F-Total
. The acknowledge LED blinks to indicate the weight
was accepted and the
TOTAL
annunciator lights. Then the total weight is displayed for five seconds and the
number of samples is displayed for two seconds.
3. Repeat steps 1 & 2 until all weight samples have been added.
Total Mode will not function while the scale is in motion, ensure
is on. If the system fails to achieve
stable readings, increase the filter setting or increase the size of the scale division (d) in the Init Cal procedure.
The F-Total functions as View Total only until the 1% threshold is exceeded to allow the addition to the total
value.
Auto Total
This mode has three variations which are programmed in the Setup menu.
Program an
F-key
to
AUTO TOTAL
, it functions as
Auto Total On
/
Auto Total Off
. See Section 4.2 on page 9.
Table 4-3. Auto Load Selections
Auto Load – ensures any settled load above the Rise Above threshold will be automatically totaled. The scale must fall
below the Drop Below threshold before the next total is allowed.
Auto Last – takes the last settled weight to auto total with. The total occurs only once the scale goes below the
threshold. This allows the load to be adjusted without a total occurring. Once the load is removed, the scale uses the
last settled reading for total.
Auto High – uses the highest settled reading. This is useful for loads that can’t be removed all at once.
To set total Mode:
1. Press
and
simultaneously to enter setup menu.
displays.
2. Press
to scroll to Total.
3. Press
to enter the total mode. The current total mode will display.
4. Press
to scroll through the available parameters.
5. When the desired setting is displayed, press
.
is displayed
6. Press
to save and return to the weigh mode.
Reset Total Load
To reset the total load to zero, press
Fx-Total
again and while the total load is being displayed, quickly press
.
Setpoint
Description
F2
F2
F1
F2
F1