About This Manual

This manual contains operating procedures for the DMC-782 coin counting scale and provides the user with all 

the information necessary for setup and operation. It is organized based on the procedures you will likely follow 

when setting up and using your coin counting scale. This manual applies to Version 1.00 of the DMC-782 coin 

counting scale series. 

This manual can be viewed or downloaded from the RLWS web site at 

www.Ricelake.com

.

1.0

Introduction

The DMC-782 is a low cost coin counting scale that offers practical solutions for a full range of coin counting 

applications. Its internal counting resolution of 1/500,000 gives you maximum counting precision and accuracy. 

The backlit LCD display enables operators to easily see weights and quantities. The DMC-782 can also store a 

coin value, tare weight, and unit weight for 23 of your coins, tokens or other items and recalls nine of them by 

pressing a single pre-programmed key. When portability is required, choose the battery operation option of the 

DMC-782 for over 380 hours of continuous use in mobile workstations, outdoor applications, and rental fleets. 

The DMC-782 is rugged enough to operate reliably in many environments and withstand transport from one area 

of the plant to another or from one business to the next.

1.1

Safety

Safety Signal Definitions:

CAUTION

Important

CAUTION

Indicates a potentially hazardous situation that, if not avoided, may result in minor to moderate injury.

Indicates information about procedures that, if not observed, could result in damage to equipment.

1.2

Safety Precautions

Do not operate or work on this equipment unless you have read and understand instructions in the 
manual. Failure to follow the instructions or heed the warnings could result in injury or death. Contact 
any Rice Lake Weighing Systems dealer for replacement manuals. Proper care is your responsibility.

 Failure to follow the instructions or heed the warnings could result in minor to moderate injury.

• Some procedures described in this manual require work inside the scale base. These procedures are to be performed 

by qualified service personnel only.

• DO NOT allow minors (children) or inexperienced persons to operate this unit.

• DO NOT use for purposes other than weight taking.

• DO NOT place fingers into slots or possible pinch points.

• DO NOT use any load-bearing component that is worn beyond 5% of the original dimension.

• DO NOT use this product if any of the components are cracked.

• DO NOT exceed the rated load limit of the unit.

• DO NOT make alterations or modifications to the unit.

• Do not drop the scale or subject it to violent shocks.

• For accurate weighing, the scale must be placed on a flat, stable surface.

• Operating voltages and frequencies other than specified could damage the equipment. 

• Weight exceeding the maximum capacity may damage your scale.

Summary of Contents for DMC-782

Page 1: ...111781 DMC 782 Counting Scale Operation Manual Coin Counting Scale Version 1 00...

Page 2: ......

Page 3: ...o the Full Capacity of the Scale 16 4 2 Calibration Using a Test Weight of Less Than the Full Capacity of the Scale 17 5 0 Scale Operations 19 5 1 Entering Recalling and Adding Subtracting Tare Weight...

Page 4: ...nd Unit Weight Where the Unit Weight is Unknown 26 6 4 Program a Preset Tare Weight to a Key 26 6 5 Delete Preset Coin Data from Memory 27 7 0 Appendix 28 7 1 DMC 782 Specifications 28 7 2 DMC 782 Err...

Page 5: ...Safety Signal Definitions CAUTION Important CAUTION Indicates a potentially hazardous situation that if not avoided may result in minor to moderate injury Indicates information about procedures that...

Page 6: ...operations take place Programming Mode where item data can be programmed into the memory of the scale The display will show ProG to indicate that you are the Programming Mode Maintenance Mode where yo...

Page 7: ...ric entry batt Battery warning when weak and needs charging blinks while charging QTY On when the quantity is being displayed rather than the value 1 5 3 Key Functions The DMC 782 features many functi...

Page 8: ...utputting data to a PC if one is connected Programming Mode Used to navigate to the previous specification when programming SPEC codes Plus key Weighing Mode Used to accumulate data Also prompts outpu...

Page 9: ...AC power cord Operation manual 3 Remove the bag protecting the scale and the protective film covering the front panel and platter 4 Seat the stainless steel platter on the platter supports 5 After en...

Page 10: ...e scale is turned upside down To power up the DMC 782 using the AC power cord 1 Connect the AC power cord under the scale base as shown in Figure 2 2 Figure 2 2 AC Plug in Location on Underside of DMC...

Page 11: ...he backlight off It is located in the bottom of the scale base Use the following procedure to install or replace the battery pack 1 Unplug the scale from power source 2 Place scale its left side Impor...

Page 12: ...to fully recharge a battery that has been completely dissipated To charge the battery plug in the AC power cord 2 4 4 Start Up Screens 1 If SPEC 20 Bit 3 Version Display When Power On is set to 0 Allo...

Page 13: ...perating manual 109241 Adhesive display window overlay DMC 782 109242 Keyboard underlay DMC 782 73524 Weighing platter DMC 782 112263 Overlay display window DMC 782 112264 Overlay keyboard DMC 782 109...

Page 14: ...82 Operation Manual 2 6 Block Diagram of Electrical Connections The following block diagram shown in Figure 2 4 illustrates the electrical connections Figure 2 4 Block Diagram Illustrating Wiring Conn...

Page 15: ...Installation 11 2 7 Physical Layout of Electrical Connections Figure 2 5 illustrates the actual layout of the electrical connections Figure 2 5 Layout of Electrical Connections...

Page 16: ...figuring Specification 141 and 142 Settings from the Scale Keyboard The following tables list the DMC 782 specifications their corresponding default values and the other possible values to which they...

Page 17: ...IFT will bring up SPEC 11 3 To change another SPEC code before exiting repeat Steps 1 and 2 4 To save all the changed SPEC settings currently in temporary memory and exit to the Weighing Mode press th...

Page 18: ...your changes per the instructions in Step 1 Alternatively you can go directly to a specific specification by entering that specification s number and pressing the SHIFT key Example 25 SHIFT will brin...

Page 19: ...ght and denomination auto clear 0 Allow 1 Inhibit DEFAULT Auto clear condition 0 Gross 21e Net 5e DEFAULT 1 Net 1e Quantity Not 0 Net Gross multi interval 0 Gross 1 Net DEFAULT 28 Accumulation 0 Allow...

Page 20: ...ian come in and check their units with certified test weights four times a year If you are ISO certified you will want to check to see if your certification specifies more stringent requirements in or...

Page 21: ...ation power down your DMC 782 scale To exit the Maintenance Mode and return to the Weighing Mode without saving your calibration press the TARE key 4 2 Calibration Using a Test Weight of Less Than the...

Page 22: ...e calibration settings 8 The display will flash briefly again as the span settings for calibration of the scale are being temporarily saved Then the display will return to the weighing mode with the c...

Page 23: ...O TARE CLEAR WHEN REZERO Bit 0 takes place or not SPEC 26 controls whether the scale allows DIGITAL TARE entry Bit 3 whether the scale can do ACCUMULATION WHEN TARE Bit 2 if there will be ZERO TRACKIN...

Page 24: ...ry Note SPEC 25 Bits 2 and 1 must be set to 00 to enable Tare Accumulation and Tare Subtraction For further instructions on how to set the specifications see Section 3 2 1 1 Place the cash drawer coin...

Page 25: ...container on the scale platform The display will show the weight denomination and total value of the coins or tokens on the scale To switch the display to show the number of coins or tokens rather tha...

Page 26: ...y mode instead of AMT mode you will hear an error beep because a quantity cannot be accumulated Switch the display back to visualizing total value by pressing the QTY AMT key and then pressing the key...

Page 27: ...t total If a PC is connected to the DMC 782 pressing the CONFIRM key again will output the data to the PC and clear the current total The Memory indicator will no longer be illuminated 5 3 Counting Co...

Page 28: ...be displayed in the Value window on the display 11 When done press the CLEAR key and the CONFIRM key to clear the total value from the accumulator You are now ready for the next cash drawer or to carr...

Page 29: ...very accurate coin unit weights using the procedure described in Section 6 2 below 6 2 Program a Value and Unit Weight Where the Unit Weight is Known The DMC 782 has the capacity to store information...

Page 30: ...n press the PCS key If the sample size is large enough to calculate an accurate unit weight that unit weight will be displayed in the Value display and the number of coins on the platform in the Amoun...

Page 31: ...Mode The display will show ProG 2 Press the preset key number for the coin data that you want to delete The key number will appear on the display for you to confirm that it is the correct key and the...

Page 32: ...ing rechargeable battery Charging Conditions for rechargeable battery only Battery Power DC 6V 5Ah rechargeable battery optional Power Source AC117 100V Charge Current 800 mA Charge Time 12 14 hours A...

Page 33: ...when the power is on Remove the item on the platter U F When the negative weight exceeds the display limit Rezero the scale or power the on off button again ERROR When an error occurs in maintenance...

Page 34: ...used by accident misuse neglect alteration improper installation improper repair or improper testing RLWS shall be the sole judge of all alleged non conformities Such equipment has not been modified a...

Page 35: ......

Page 36: ...2013 Rice Lake Weighing Systems PN 111781 01 13...