CLS-920i Installation Manual
Figure 4-6. SCALES Menu, CALIBR Submenu
Table 4-4. SCALES Menu, CALIBR Submenu Parameters
SCALES Menu, CALIBR Submenu
Parameter
Choices
Description
Level 4, CALIBR submenu
WZERO
—
Press ENTER to display and edit the zero calibration A/D count or millivolts value.
WVAL
—
Press ENTER to display and edit the test weight value.
WSPAN
—
Press ENTER to display and edit the span calibration A/D count or millivolts value.
WLIN
POINT 1 —
POINT 5
Press ENTER to display and edit test weight and calibration values for up to five linearization points.
Perform linear calibration only after WZERO and WSPAN have been set.
REZERO
—
Press ENTER to remove an offset value from the zero and span calibrations.
Note
Use this parameter only after WZERO and WSPAN have been set.
Note
For the CLS Series Cargo Lift Scale, do not use this section as reference for calibration. Please refer to. Section
6.0 for complete calibration instructions.
Summary of Contents for CLS-920i
Page 2: ...96312 Rev A CLS 920i 920i Cargo Lift Scale Installation Manual...
Page 3: ......
Page 76: ...CLS 920i Installation Manual 72...
Page 77: ...73 CLS 920i Installation Manual...
Page 96: ......
Page 97: ...PN 96312 11 12...