590 AG Indicator Operators Manual
5.1.2
Reporting Commands
Reporting commands (see Table 5-2) send specific
information to the EDP port. These commands can be
used in both setup mode and normal mode.
5.1.3
The RESETCONFIGURATION Command
The RESETCONFIGURATION command can be used
to restore all configuration parameters to their default
values. Before issuing this command, the indicator must
be placed in setup mode or test mode (press and hold
setup switch for approximately four seconds to enter
test mode).
Sending this command, followed by the RS (RESET)
EDP command, is equivalent to using the DEFLT
function on the TEST menu. See Section 8.7 for more
information about test mode and using the TEST menu.
NOTE:
All load cell calibration settings are lost when
the RESETCONFIGURATION command is run.
5.1.4
Parameter Setting Commands
Parameter setting commands allow you to display or change the current value for a particular configuration
parameter (Table 5-3 through Table 5-8).
Current configuration parameter settings can be displayed in either setup mode or normal mode using the following
syntax:
command
<ENTER>
Most parameter values can be changed in setup mode only. Use the following command syntax when changing
parameter values:
command
=
value
<ENTER>
where
value
is either a number or a parameter value. Use no spaces before or after the equal (=) sign. If you type an
incorrect command, the display reads
??
. Changes to the parameters do not take effect until you exit setup mode.
For example, to set the motion band parameter to 5, type the following:
MOTBAND
=
5D
<ENTER>
Command
Description
Values
GRADS
Graduations
1–999 999
ZTRKBND
Zero track band
OFF, 0.5D, 1D, 3D
ZRANGE
Zero range
1.9%, 100%
MOTBAND
Motion band
1D, 2D, 3D, 5D, 10D, 20D, OFF
OVRLOAD
Overload
FS+2%, FS+1D, FS+9D, FS
SMPRAT
Sample rate
15HZ, 30HZ, 3.75HZ, 7.5HZ
DIGFLTR1
DIGFLTR2
DIGFLTR3
Digital filtering
1, 2, 4, 8, 16, 32, 64
DFSENS
Digital filter cutout sensitivity
2OUT, 4OUT, 8OUT, 16OUT, 32OUT, 64OUT, 128OUT
DFTHRH
Digital filter cutout threshold
NONE, 2DD, 5DD, 10DD, 20DD, 50DD, 100DD, 200DD, 250DD
Table 5-3. CONFIG EDP Commands
Command
Function
DUMPALL
List all parameter values
VERSION
Write
590 AG Indicator
software version
RS
Reset the indicator
P
Write current displayed weight with units
identifier.
The P command returns the current
displayed weight value to the EDP port. If
the indicator is in an underrange or overload
condition, the weight value is replaced with
###### (overload) or %%%%%%
(underrange).
S
Write one frame of stream format
Table 5-2. EDP Reporting Commands