This section describes the front panel and includes procedures for operation of the scale.

Figure 3-1. Front Panel Keypad

3.1 Key Descriptions

The display has 10 front panel keys. Key functions are described in the table below.

  The front panel keys are very sensitive, so only a gentle press is required.

Key

Name

Function

On/Off

Powers the scale on or off

Print 

LB/KG

Sends data out from the RS-232 port; Allows to toggle between kilograms and pounds providing that it is enabled in 

Configuration

 mode; Cannot toggle while in the 

BMI

 mode

Zero

Only functions if the current weight is stable and less than 2% of the capacity of the scale. Anything over 2% requires 

a recalibration

Hold Release Displays most current weight value on the display and holds that value when the patient is off the scale. A second 

press releases the weight value. Not active while in 

BMI

 mode

BMI

Pressing the 

BMI

 key enables access to the BMI (Body Mass Index) mode (defaults when scale is turned on). The 

patient is gets on the scale, weight stabilizes and press the 

BMI

 key. The display then asks for the patient height to 

calculate out the patient BMI.   

TARE

Used to remove the weight initially of anything on the scale that shouldn’t be included in the total weight of the 

patient on the scale 

CLEAR

When using the BMI function, the display looks for a height entry. Pressing 

Clear

 changes this entry back to 190.0 

cm (default) or 5 ft, 7.5 in.Once BMI is displayed, pressing the 

Clear

 key exits BMI

ENTER

Used to accept height in 

BMI

 mode; accepts the value of the parameter last entered and moves to the next stage

Pressing and holding Enter during startup will display ID. This is the first setup on entering into configuration mode

Up Arrows

Adjusts the value of the flashing digit/number

Adjusts height input (0.5 in/0.5 cm) while in 

BMI

 mode

Down Arrows Adjusts the value of the flashing digit/number

Adjusts height input (0.5 in/0.5 cm) while in 

BMI

 mode

Table 3-1.  Key Functions

IMPORTANT

On/Off

LB/KG

Print

Zero

Hold

Release

BMI

TARE

T

CLEAR

ENTER

Summary of Contents for 250-10-2

Page 1: ...250 10 2 Bariatric Handrail Scale Software Version 11525 Technical Manual PN 151436 Rev D August 17 2022...

Page 2: ...respective companies All information contained within this publication is to the best of our knowledge complete and accurate at the time of publication Rice Lake Weighing Systems reserves the right to...

Page 3: ...ing or obtained by calling 715 234 9171 and asking for the training department Revision History This section tracks and describes the current and previous manual revisions for awareness of major updat...

Page 4: ...ghing 6 3 3 Hold Release Function 6 3 4 Preset Tare 6 3 5 Toggle Tare 6 3 6 Using the Body Mass Index BMI Function 7 3 6 1 LB Mode 7 3 6 2 KG Mode 7 3 7 Troubleshooting 8 4 0 Configuration 9 4 1 Setup...

Page 5: ...se limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio freq...

Page 6: ...rt the scale while someone is on the scale Do not allow minors children or inexperienced persons to operate this scale Do not use in the presence of flammable materials Do not use this product if any...

Page 7: ...e must be returned or moved The product must be properly packed with sufficient packing materials Whenever possible use the original carton and packing materials when shipping the scale back Damage ca...

Page 8: ...age of 25 hours of continuous use To install the batteries 1 Turn thumbscrew counterclockwise then remove battery cover 2 Insert batteries into the battery chamber as illustrated Figure 2 2 Battery Ch...

Page 9: ...sing the BMI key enables access to the BMI Body Mass Index mode defaults when scale is turned on The patient is gets on the scale weight stabilizes and press the BMI key The display then asks for the...

Page 10: ...used by the patient 1 Press to turn on the scale 0 0 appears on the display along with the ZERO annunciator 2 Place additional item s on the scale 3 Press until the display returns to 0 0 and NET annu...

Page 11: ...the height value 5 Press 6 The BMI value and BMI annunciator are shown on the display Press to return to the Weighing mode and the BMI function will be turned off 3 6 2 KG Mode 1 Ensure that the scal...

Page 12: ...D too high E07 AD too low E10 Overload Scale has been overloaded Remove load from scale E4L BAT Battery low but still usable one bar left on indicator display E4U Battery low and unstable no bars left...

Page 13: ...enus and or parameters Press to enter a displayed menu and or parameter Press or to scroll through values Press to save the displayed selection and move to the next parameter 4 2 2 Enter Numbers Press...

Page 14: ...h located in the back of the scale to enter the setup parameters for the scale Use a small paper clip small screwdriver or other similar object to press the setup switch 4 Once the setup switch is pre...

Page 15: ...the Up Down arrow keys to increment decrement numbers 7 When done press ENTER key to move to the next parameter LOAD LOAD This is the amount of weight applied during calibration Can also be changed in...

Page 16: ...2 5 10 20 50 100 Values in lb 1 2 5 10 20 50 100 200 0 2 0 5 1 0 2 0 5 0 10 0 20 0 0 1 The display toggles between a numeric value and ROUND The decimal point location is set to the DISP parameter dis...

Page 17: ...the following steps 1 Press the ENTER key to change values 2 Use the Up Down arrow keys to change the available parameters 3 When done press ENTER key to move to the next parameter UNITS UNITS Units...

Page 18: ...f the scale to enter the setup parameters for the scale Use a small paper clip small screwdriver or other similar object to press the setup switch on the back of the indicator under the cover 4 Prog d...

Page 19: ...the scale until ID flashes 2 Press again 3 Continue to press to scroll through the various menu items 4 Once complete press again then Done displays 5 Press to start the weighing process Figure 4 5 T...

Page 20: ...the weight was either in motion or out of range If displaying weight and not BMI the scale will send out the following 21 character string xxxxxxxxx SP uu SP mmmmm SP CR LF Example 60 1 KG PATIENT SP...

Page 21: ...rotocol Commands Name ESC Character ESC Value with Parameters Description Reading R R Tells PC the scale is sending a reading immediately following this is the value that is sent Example ESC R ESC W02...

Page 22: ...AD Z Zero the scale F Show flash values used for the first flash process L USB On Off not available on USB communication Table 5 5 Maintenance Protocol Commands Escape Protocol Example 1 Escape Protoc...

Page 23: ...the use of the USB driver Driver protections may need to be temporarily disabled on Windows 10 or later computers to allow for the installation of the USB driver 1 Connect the scale s indicator to a P...

Page 24: ...personnel Go through the following steps for basic maintenance Check the overall appearance of the entire scale for any obvious signs of damage Inspect the condition of the AC power adapter cord for...

Page 25: ...off can be configured Data Communications RS 232 with RJ 45 jack USB connection Selectable baud rate default 9600 8 bits No parity 1 stop bit No handshaking Environmental Operating Temperature 50 F t...

Page 26: ...250 10 2 Bariatric Handrail Scale 22 Visit our website www RiceLake com...

Page 27: ......

Page 28: ...54868 USA U S 800 472 6703 Canada Mexico 800 321 6703 International 715 234 9171 Europe 31 0 26 472 1319 Rice Lake Weighing Systems Specifications subject to change without notice www ricelake com PN...

Reviews: