Ribiland 517266 User And Maintenance Manual Download Page 3

GB

 

Directions for maintenance & use 

SURPRESSOR PUMP JET 81-101-121 

 

WARNING!  

In order to reduce the risks of fire, electric shock and personal injury during the course of 

installation and use of your pump, it is recommended that you always adhere to basic safety precautions, 

including the following: 

 

Read these instructions in their entirety before operating this machine and retain these instructions, 

 

1)

 

GENERAL REMARKS 

The water pump is designed to suck up treated water. 

The pump must be installed in a dry, ventilated location, not exposed to bad weather and heat; the maximum 

suction height must not exceed 8 meters. 

When correctly installed, your pump will operate with maximum efficiency and entirely to your satisfaction: 

be sure to read the following instructions carefully. 

 

2)

 

TECHNICAL DATA 

Water pumps may come equipped with tanks of stainless steel or steel with 19, 24, 36 or 50 liter capacity. 

The reference assigned depends on the type of tank supplied: 

 

Capacity 

19 L 

24 L 

36 L 

50 L 

Material 

used 

STEEL S.STEEL STEEL S.STEEL STEEL S.STEEL STEEL S.STEEL 

JET 

81  517616 517616I 517636 517636I 517656 517656I 517676 517676I 

JET101  517716 517716I 517736  517266  517756 517756I 517776 517776I 

JET121  517816 517816I 517836 517836I 517856 517856I 517871 517871I 

 
The specifications set out below are the same irrespective of the tank supplied: 

Model 

JET 81 

JET 101 

JET 121 

Type    

Self-priming 

Self-priming Self-priming 

Max suction     

8 m 

8 m 

8 m 

Output    

28 l/min at 8m 

33 l/min at 8m 

35 l/min at 8m 

Discharge   

24l/min at 15m 

28 l/min at 15m 

31 l/min at 15m 

Motor power   

750 W 

970 W 

1180 W 

Power supply 

230 V/ 50Hz 

230 V/ 50Hz 

230 V/ 50Hz 

Speed                               

(rounds / minute)

 

2850 2850 2850 

 

3)

 

USE AND INSTALLATION

 

a)

 

Use: 

The water pump is designed for everyday use such as gardening, sprinkler systems, increasing water 

pressure of the non-feed water distribution network, pumping of tank water and jet washing. The 

pump/booster assembly maximizes water storage by limiting frequency of operation, and in particular 

ensures constant pressure is maintained in the installation. 

The pump must not be operated for uses not specified in this manual. 

In particular, the pump must not be use for: 

-   Pumping of seawater, waste water, water containing solid bodies, sand or abrasive particles in 

suspension, or water containing corrosive substances in general. 

-      Pumping of water whose temperature exceeds 35  

-      Pumping of explosive, inflammable or dangerous liquids. 

 

b)

 

Major recommendations: 

Before connecting up to the electricity network, you must:   

-      Fasten the pump securely to the ground or a suitable support. 

With that in mind, the four feet of the tank have been perforated so as to allow fastening bolts (not 

supplied) to go through. 

 

2

Summary of Contents for 517266

Page 1: ...manual IT POMPA DA SUPERFICIE AUTODESCANTE CON SERBATOIO Manuale di istruzioni e di manutenzione DE SELBSTANSAUGENDEN HAUSWASSERWERKE Bedienungs und Wartungsanleitung ES BOMBA PERIFERICA DE CEBO AUTO...

Page 2: ...RTENZA Leggere attentamente questo manuale di istruzioni prima di utilizzare il prodotto Il funzionamento non corretto pu causare lesioni e o danni Conservare il presente manuale per futuri consulti A...

Page 3: ...56I 517871 517871I The specifications set out below are the same irrespective of the tank supplied Model JET 81 JET 101 JET 121 Type Self priming Self priming Self priming Max suction 8 m 8 m 8 m Outp...

Page 4: ...d 3 Turn off power of the wall socket which the pump will be connected to using the separation device see section entitled Major recommendations 4 Connect the cable plug to the 10 16A wall socket The...

Page 5: ...ereby avoiding pressure fluctuations hammering IMPORTANT Do not operate the pump without there being water in the pump casing prolonged operation of the pump while the discharge line valve is closed m...

Page 6: ...fournie Mod le JET 81 JET 101 JET 121 Type Auto amor ante Auto amor ante Auto amor ante Aspiration maxi 8 m 8 m 8 m D bit 28 l min 8 m 33 l min 8 m 35 l min 8 m 24 l min 15 m 28 l min 15 m 31 l min 1...

Page 7: ...re fonctionner la pompe plus de 2 3 secondes vide afin d viter une surchauffe excessive Cela provoquerait des dommages irr m diables 6 Lorsque l alimentation est nouveau coup e effectuer les brancheme...

Page 8: ...r s rieusement la pompe En cas de panne de courant il est pr f rable de d brancher la fiche de prise de courant ou de d sactiver l interrupteur commandant la pompe En cas d inutilisation prolong e de...

Page 9: ...Die nachfolgend aufgef hrten Daten sind unabh ngig vom verwendeten Tank Modell JET 81 JET 101 JET 121 Typ selbstansaugend selbstansaugend selbstansaugend Max Ansaugung 8 m 8 m 8 m F rdermenge 28l min...

Page 10: ...Pumpe angegebenen bereinstimmt 2 Sicherstellen dass das Anschlusskabel nicht besch digt ist 3 Stromversorgung der Steckdose an die die Pumpe angeschlossen wird mit Hilfe der Trennvorrichtung abschalte...

Page 11: ...daraus folgende Druckschwankungen zu verhindern WICHTIG Pumpe keinesfalls ohne Wasser im Pumpengeh use betreiben Ein l ngerer Betrieb der Pumpe mit geschlossenem Ablassventil kann zu schweren Sch den...

Page 12: ...Tipo Autoadescante Autoadescante Autoadescante Aspirazione massima 8 m 8 m 8 m Portata 28 l min a 8 m 33 l min a 8 m 35 l min a 8 m Erogazione 24 l min a 15 m 28 l min a 15 m 31 l min a 15 m Potenza...

Page 13: ...ntazione per qualche secondo per effettuare una prova di funzionamento a vuoto della pompa Non fare funzionare a vuoto la pompa per pi di 2 3 secondi onde evitare un eccessivo surriscaldamento che pot...

Page 14: ...are funzionare la pompa senza che vi sia acqua nel corpo della stessa un funzionamento prolungato della pompa con il rubinetto di mandata chiuso pu provocare gravi danni In caso di interruzione di cor...

Page 15: ...indicadas debajo son las mismas para los diferentes modelos de tanque suministrado Modelo JET 81 JET 101 JET 121 Tipo auto cebante auto cebante auto cebante Aspiraci n m x 8 m 8 m 8 m Caudal 8m a 28 l...

Page 16: ...nistro el ctrico durante unos segundos para realizar una prueba en vac o de la bomba No utilice la bomba durante m s de 2 3 segundos para evitar un sobrecalentamiento excesivo de lo contrario se podr...

Page 17: ...nte un per odo prolongado con el tubo de desag e cerrado se pueden producir graves da os en la bomba Si existe un corte del suministro el ctrico se recomienda desconectar el enchufe de alimentaci n o...