RCI-15
72
ZSME300000050
Function Configuration Menu
Setting value
Item
Function
Parameter
Description
Default
SQ- 10
Discharge start delay
time
0.0 ~ 25.5
(sec)
Delay time before Discharge signal is ON.
0.0
SQ- 11
Discharge stop delay
time
0.0 ~ 25.5
(sec)
Delay time before Discharge signal is OFF.
0.0
SQ- 12
Discharge time
0.0 ~ 25.5
(sec)
Won
’
t activate internal discharge control
function, if set to 0.
0
Discharge input signal
Weight reach zero band
SQ- 10
Discharge output signal
SQ- 11
SQ- 13 Restart delay time
0.0 ~ 25.5
(sec)
Delay time before Restart signal is ON.
1.0
SQ- 14
Batching counts
0 ~ 255
(times)
Number of batch runs
0
⇒
one batch only
0
0
No setting
SQ- 15
Set the zero band in to
final weighing value
1
Setting
0
0
Comparison anytime
1
To compare at batch finish
2
To compare at external input signal
3
To compare at batching finish and external input signal.
SQ- 16
Hi, OK, Lo
4
Comparison auto
0
0
Disabled
SQ- 17
Auto accu. weight /
counts
1
Enabled
0
0
Key in directly from front keypad
SQ- 18
The parameter
source in weight
comparison
1
Input directly from rear interface
0
SQ- 19
Weight comparison
delay time
0.0 ~ 25.5
(sec)
Comparison delay time for Hi, OK, Lo
0.5
0
Press keypad TARE to TARE
SQ- 20
TARE auto.
1
TARE auto
0
0
Input from external input or keypad
SQ- 21
Discharge auto
1
Discharge auto + manual
0