RCI-15
51
ZSME300000050
2
Function setting
Press key
Input desired
Parameter code
Press key
Display shows the existing
parameter code. Input
new code as required.
Press the key
Continue to another function setting
or press to escape
Setting value
Item
Function
Parameter
Description
Default
0
As display
1
Gross
AnL- 01
Data type
2
Net
0
0
Current output
AnL- 02
Signal output
1
Voltage output
0
AnL- 03
Weight in Lo
000000 ~ 999999
0
AnL- 04
Current / Voltage
in Lo
0.0 mA ~ 20.0 mA
or
0.0 V ~ 10.0 V
When the weight reaches the value of
that in AnL-03, the current / voltage
output is changed to that configured in
AnL-04.
4.0
AnL- 05
Weight in Hi
000000 ~ 999999
300000
AnL- 06
Current / Voltage
in Hi
0.0 mA ~ 20.0 mA
or
0.0 V ~ 10.0 V
When the weight reaches the value of
that in AnL-05, the current / voltage
output is changed to that configured in
AnL-06.
20.0
⇒
Increment flashing
digit
⇒
Decrement flashing
digit
⇒
Move flashing point
left.
⇒
Move flashing point
right
⇒
Store data in
memory
⇒
Exit
/
Escape
G/N
•
F1
‚
F
ƒ
F2
„