background image

36

The STOP button stops the gate during any operation.

If held when the gate is fully open (or partially when using the pedestrian control) automatic 
closing is temporarily deactivated (if activated by the TCA trimmer and LED DL11 on). It is 
therefore necessary to use a new command to make it close.
The automatic closing function is reactivated on the next cycle (if activated by the TCA 
trimmer and LED DL11 ON).

FUNCTIONING IN HOLD-TO-RUN MODE WHEN THE SAFETY DEVICES ARE FAILING

If one of the safety edges fails or remains engaged for more than 5 s, or if one of the  photocells 
fails or remain engaded for more than 60 seconds, the OPEN, CLOSE, START and PED. commands 
will work only in hold-to-run mode.
The signal that this mode has been activated is given by the blinking of the programming led 
DL1.
The radio commands and the automatic closing will be excluded, since their use in this mode 
is not allowed by the norms.
Once the failing safety device is repaired, in automatic after 1 second, all standard commands 
functioning again so radio commands and the automatic closing will be enabled again.

Note 1:  during this functioning in hold-to-run mode, in case of damage to the safety strips (or 

photocells) the photocells (or safety strips) still work by interrupting the operation 
in progress.

Note 2:  the stop command is not to be considered a safety command that can be bypassed 

in this mode. Therefore, when pressed or damaged, it will not allow any movement 
of the gate.

The hold-to-run mode is only an emergency operation which must be activated for a very 
short period and with the complete installation at sight so to have a secure and safe control 
of the system. As soon as possible however, the failing safety devices must be repaired and 
activated.

VISUAL AND SOUND ALARMS

BLINKER

Connect the flashing light to the blinker output, use flashing lights ACG7072 and bulbs of 40W 
maximum.

PRE-BLINKING
DIP 5 OFF =>

 motor and blinker start simultaneously.

DIP 5 ON =>

 blinker starts 3 seconds before the motor.

BUZZER 

It has the task to signal the intervention of the security, the anomalies and the memorization 
and cancellation of the radio codes.

SIGNAL - 24Vdc GATE OPEN WARNING LIGHT (COM A+/SIGNAL-)

Signals when the gate is open, partially open or not closed completely. It turns OFF only when 
the gate is completely closed.
During opening, it flashes slowly.
When the gate is stationary or opened, it is permanently on.
During closing, it flashes quickly

N.B.:  Max 3 W. If warning lights are in excess, the control panel processes will be endangered 

with possible stop of all operations.

OPERATION AFTER BLACK-OUT

At the time of the blackout, gate status is saved in the memory.
When mains voltage is restored:

If the gate is located on the

 opening or closing limit switch, operating the control will close or 

open the gate with the saved data.

If the gate is in intermediate position

, operating the control will open the gate slowly until 

it reaches the opening limit switch. After completing this first movement, the operator will 
resume work at the set speed.

TECHNICAL SPECIFICATIONS

- Humidity 

 < 95% without condensation

- Power voltage 

 230V~ ±10% (120V/60Hz upon request)  

- Frequency 

50/60Hz

- Maximum board absorption 

30mA

- Interruptions in electricity supply 

100ms

- Maximum load of open gate output 

 3 W (equal to 1 3W bulb or to 5 LEDs 
connected in series through a resistor 
of from 2.2 Kohm)

- Blinking unit maximum output load 

 40W with resistive load

- Current available for photocells and accessories 

400mA 24Vdc

- Current available on radio connector 

200mA 24Vdc

-  ALL THE PUSH BUTTONS, INPUTS AND COMMANDS CONNECTED TO THE CONTROL BOARD MUST BE 

CLEAN CONTACT.

TECHNICAL RADIO SPECIFICATIONS (Only L1-CRX)

- Reception frequency  

433,92MHz

- Impedance  

52 Ω

- Sensitivity  

>2.24µV

- Excitation time  

300ms

- De-excitation time  

300ms

- Codes in store  

N° 1000 total

-  All the inputs must be used as clean contacts because the power supply is generated 

internally (safe voltage) in the card and it is set in a way to guarantee the use of the double 
insulation and reinforced in relation to parts with hazardous voltage.    

-  Any external circuits connected to the outputs of the control board, must be carried out to 

make sure the double or reinforced insulation is used in relation to parts with hazardous 
voltage.

-  All the inputs are run by a programmed integrated circuit  which carries out a self-check at 

the beginning of each operation. 

MAINTENANCE CHECK

N.B.:  During this check the safety functions Edges, Photocells and Stop button are NOT active.

1 - Set 

DIP 1 to ON

 => LED DL1 starts to flash.

2 -  Press and hold the PROG button (the command is hold-to-run, open-stop-close-stop-open-

etc ...) => The gate starts at high speed and then slow down until the limit switch is reached.

3 -  At the end, put 

DIP 1 back to OFF

. The DL1 LED turn OFF signaling the exit from the check.

If the motor does not work during this check, check the connections and its capacitor.
If the motor is working properly, check the safety devices.

TROUBLE SHOOTING

After having carried out all connections, by carefully following the layout and having positioned 
the gate in intermediate position, check the correct ignition of red LEDS DL6, DL7, DL8, DL9 
and DL10.
In case of no ignition of the LEDS, always with gate in intermediate position, check the following 
and replace any faulty components.
DL6 

OFF   Stop button malfunction (if Stop is not connected, perform the jump 

between COM A+ and STOP).

DL7 or DL8  OFF   Faulty photocells (In case the edge is not connected, carry out jumper 

between COM A+ and PHOTO 1/PHOTO 2)

DL9 or DL10  OFF   Faulty safety edge (In case the edge is not connected, carry out jumper 

between COM A+ and EDGE 1/EDGE 2)

DL13 blue 

ON   Some functions are enabled via smartphone, so via smartphone check the 

card functions as the dips/trimmers status may not be true.

On the board there are resettable fuses which intervene in the event of a short circuit, 
interrupting the output assigned to them.
In the event of troubleshooting, it is advisable to disconnect all the removable connectors and 
insert them one at a time in order to more easily identify the cause of the fault.

G

B

Summary of Contents for SUPER 6000

Page 1: ...0 ICE AA38006 Il corretto funzionamento dell operatore garantito solo se viene gestito da un quadro di comando RIB Le bon fonctionnement de l op rateur n est garanti que s il est g r par un panneau de...

Page 2: ...ovocati dalla mancata osservanza nell installazione delle norme di sicurezza e delle leggi attualmente in vigore ATTENTION POUR LA SECURITE DES PERSONNES IL EST IMPORTANT DE SUIVRE TOUTES LES INSTRUCT...

Page 3: ...sed by the non observance during the installation of the safety standards and of the laws in force at present ACHTUNG F R DIE SICHERHEIT DER PERSONEN IST ES WICHTIG DASS ALLE ANWEISUNGEN GENAU AUSGEF...

Page 4: ...dell acquisto di una nuova apparecchiatura di tipo equivalente Presso i distributori di prodotti elettronici con superficie di vendita di almeno 400 m2 inoltre possibile consegnare gratuitamente senz...

Page 5: ...ture che ammorbidisce le partenze gli arresti e le inversioni di marcia delle enormi masse in movimento Il suo motore autofrenante utile per limitare in fermata l inerzia del cancello Misure in mm 1 I...

Page 6: ...norma EN 12453 TIPO DI COMANDO USO DELLA CHIUSURA Persone esperte fuori da area pubblica Persone esperte area pubblica Persone non esperte mantenuto A B non possibile impulsivo in vista es pulsante C...

Page 7: ...FRIZIONE Effettuare il primo cambio dell olio dopo 2 mesi e successivamente ogni anno TIPI D OLIO RACCOMANDATI AGIP OSO 35 SHELL TELLUS OIL 29 FINA HEDRAN 31 BP ENERGOIL HL 65 TERESSO 43 ARAL E 100 E...

Page 8: ...SINGOLO LED R 2 2K 1 4W ENCODER COMUNE COMUNE COMUNE COMUNE COSTA 2 FOTOCELLULA 2 COSTA 1 24Vdc 0 4A 15 24Vdc 0 4A 15 A TEST A AUTOTEST FOTOCELLULE ANTENNA 433 MHz SCHERMATURA CAVO D ANTENNA 700 W MAX...

Page 9: ...COM Positivo alimentazione accessori a 24 Vdc Comune dei contatti A Negativo alimentazione accessori a 24 Vdc A TEST Positivo per alimentazione autotest fotocellule a 24 Vdc J5 COM A Comune dei contat...

Page 10: ...PHOT1 PHOT2 EDGE1eEDGE2nonsonocollegati eseguiredeiponticellitra COMA STOP PHOT1 PHOT2 EDGE1 EDGE2primadiprocedereconlaprogrammazione N B In questo caso le sicurezza Costa Fotocellule e Pulsante di st...

Page 11: ...sizionare prima il DIP 1 su ON il DIP 2 su ON e poi il DIP 3 su ON Il led DL12 lampeggia arancio per 10 secondi 2 Entro questi 10 secondi premere e mantenere premuto il pulsante PROG per 5 secondi La...

Page 12: ...FF Il motore ed il lampeggiatore partono contemporaneamente DIP 5 ON Il lampeggiatore parte 3 secondi prima del motore BUZZER Ha il compito di segnalare l intervento delle sicurezze lo stato degli all...

Page 13: ...codici radio per rel R AUX spento Spento Lampeggia arancio per 10 secondi Programmazione corretta dei codici radio per apertura totale e R AUX 1 Tono Spento Si accende verde una volta Programmazione...

Page 14: ...est fotocellule fallito verificare i collegamenti tra quadro elettronico e fotocellule Il cancello non apre e non chiude azionando i vari pulsanti START RADIO OPEN e CLOSE Contatto costa guasto Contat...

Page 15: ...e la centrale tramite rete Wi Fi locale WLAN APP8066 Modulo RJ45 per Scheda APP per gestire la centrale tramite rete dati locale LAN NOVA NOVA WIRELESS EN12978 EN13849 2 FOTOCELLULE NOVA portata 25 m...

Page 16: ...RE RADIO RED per costa meccanica o elettrica da alimentare con 3 batterie stilo tipo AA da 1 5V non incluse RED permette la realizzazione di un impianto con coste fissate anche sull anta in movimento...

Page 17: ...aux differences de temp ratures il assouplit les d parts les arr ts et les inversions des grandes masse en mouvement son moteur autofreinant est utile pour limiter l inertie du portail pendant l arr t...

Page 18: ...nt la norme EN 12453 TYPEDECOMMANDE USAGE DE LA FERMETURE Personne expertes zone sans publique Personne expertes zone avec publique Personnes non expertes homme presente A B Pas possible impulsion en...

Page 19: ...premi re vindage de l huile apr s 2 mois et ensuite tous les ans TYPES D HUILE PRECONISES AGIP OSO 35 SHELL TELLUS OIL 29 FINA HEDRAM 31 BP ENERGOIL HL65 TERESSO 43 ARAL E100 EXTRA MOBIL ATF2000 CHEV...

Page 20: ...DE UNIQUE LED R 2 2K 1 4W ENCODER COMMUN COMMUN COMMUN COMMUN CORDON 2 PHOTOCELLULES 2 CORDON 1 A TEST A AUTOTEST PHOTOCELULES ANTENNE 433 MHz ENVELOPPE ANTENNE 24Vdc 0 4A 15 24Vdc 0 4A 15 700 W MAX C...

Page 21: ...cc A TEST Positif pour alimentation autotest photocellules 24 Vcc J5 COM A Commun des contacts Positif 24 Vdc B I O Contact horloge NO PED Contact commande ouverture pour pi tons NO START Contact une...

Page 22: ...ocellules et Stop sont actives et leur niveau de performance est PL c selon EN13849 1 leur intervention arr te la programmation le led DL1 reste allum N B Si les entr es STOP PHOT 1 PHOT 2 EDGE 1 et E...

Page 23: ...ivante 3 Pour terminer la programmation laisser s couler 10 sec ou bien appuyer pendant un instant sur le bouton PROG La LED DL12 arr te de clignoter 4 Repositionner DIP 1 2 et 3 sur OFF PROCEDURE D E...

Page 24: ...la s curit dans ce mode si il est press ou en panne il ne permet pas de tout mouvement La manoeuvre con commande maintenue est exclusivement une manoeuvre d urgence qui doit tre effectu e pour des tem...

Page 25: ...actionnant le bouton START OPEN ou CLOSE le portail n effectue aucun mouvement Impulsion START OPEN ou CLOSE toujours ins r e Contr ler et remplacer les ventuels boutons ou microrupteurs du s lecteur...

Page 26: ...Suppression codes ouverture totale pi ton et R AUX 2 Tonalit s teint Effectue 2 clignotements verts SIGNALISATIONS PENDANT LE FONCTIONNEMENT V NEMENT TAT BUZZER TAT CLIGNOTEUR TAT LED ET SORTIE SIGNA...

Page 27: ...le tableau de contr le via Bluetooth 4 2 APP8064 Module Wi Fi pour Carte APP pour g rer le tableau de contr le via un r seau Wi Fi local WLAN APP8066 Module RJ45 pour Carte APP pour g rer le tableau...

Page 28: ...NSMETTEUR RADIO RED pour barre palpeuse m canique ou lectrique alimenter par 3 piles de type AA de 1 5V non comprise RED permet la r alisation d une installation avec barres palpeuses fix es galement...

Page 29: ...or is able to limit gate inertia during the stopping phase Measurements in mm inch 25 9 8 2 2 16 13 3 6 7 2 0 8 11 4 4 3 G B SYSTEM LAY OUT TECHNICAL DATA SUPER 6000 Max leaf weight kg 6000 Operating...

Page 30: ...rding to EN 12453 standard COMMAND TYPE USE OF THE SHUTTER Skilled persons out of public area Skilled persons public area Notskilled persons Hold to run operation A B Not possible Impulsive in sight e...

Page 31: ...months service and once a year from then on RECOMMENDED TYPES OF OIL AGIP OSO 35 SHELL TELLUS OIL 29 FINA HEDRAN 31 BP ENERGOL HL 65 TERESSO 43 ARAL E100 EXTRA MOBIL ATF 2000 CHEVRON OC TURBINE OIL 11...

Page 32: ...GLE COMMAND LED R 2 2K 1 4W ENCODER COMMON COMMON COMMON COMMON EDGE 2 PHOTOCELL 2 EDGE 1 A TEST A PHOTOCELLS AUTO TEST ANTENNA 433 MHz ANTENNA BRAIDING 24Vdc 0 4A 15 24Vdc 0 4A 15 700 W MAX CONNECTIO...

Page 33: ...COM 24Vdc accessories power supply Common contacts A 24Vdc accessories power supply A TEST 24Vdc photocells self test power supply J5 COM A Common contacts Positive 24 Vdc B I O Contact NO dedicated...

Page 34: ...this case the safety Edge Photocells and Stop button will be ignored N B The start slow down point is automatically determined in the time programming phase and 50 60 cm is activated before reaching t...

Page 35: ...O This function is useful during peak hours when vehicle traffic is slow e g entry exit of workers emergencies in parking or residential areas and temporarily for moving operations By connecting a sw...

Page 36: ...ening limit switch After completing this first movement the operator will resume work at the set speed TECHNICAL SPECIFICATIONS Humidity 95 without condensation Power voltage 230V 10 120V 60Hz upon re...

Page 37: ...y 5 s for 1 minute It is renewed by giving a command Flashes for 1 minute No led combined Failed photocells auto test alarm 4 Tones every 5 s for 1 minute It is renewed by giving a command OFF No led...

Page 38: ...WIRELESS EN12978 EN13849 2 PHOTOCELLS NOVA range 25 m code ACG8046 PHOTOCELLS NOVA WIRELESS range 25 m 3 years batteries life code ACG8047 PAIR OF COLUMNS for NOVA code ACG8039 G B PLATE TO BE CEMENT...

Page 39: ...th 4 2 transmission APP8054 APP card to manage the control panel using Bluetooth 4 2 transmission APP8060 Clock module for APP card to add access control features to the control panel APP8064 Wi Fi mo...

Page 40: ...OUT WIRES code ACG3016 RED RADIO TRANSMITTER for mechanical and electrical safety strip Batteries not included RED allows to make a system made with edges fixed to the moving shutter without having to...

Page 41: ...die einfach zum Eichen ist und die Abfahrt die Sperre und die Umschaltung der groessen Massen die in Bewegung sind erweicht Sein selbstbremsantrieb ist nuetzlich um die Torestr gheit zum Stillstand be...

Page 42: ...onen au erhalb des ffentlichen Bereichs Erfahrene Personen ffentlicher Bereich Nicht fachkundige Personen Gedr ckt halten A B nicht m glich Impulsiv in Sicht z B Wandtaster C oder E C oder E C und D o...

Page 43: ...ne von 2 s mu es die Betriebsgeschwindigkeit erreichen WARTUNG DER KUPPLUNG Den ersten lwechsel nach 2 Monaten und dann jeweils einmal pro Jahr ausf hren EMPFOHLENE LSORTEN AGIPOSO35 SHELLTELLUSOIL29...

Page 44: ...RDUNGSKONTAKT GEMEINSAMER ERDUNGSKONTAKT GEMEINSAMER ERDUNGSKONTAKT GEMEINSAMER GEMEINSAMER KONTAKTLEISTE 2 FOTOZELLE 2 KONTAKTLEISTE 1 A TEST A AUTOTEST FOTOZELLEN ANTENNE 433 MHz ANTENNE ZOPFFLECHTE...

Page 45: ...ung der Zubeh re zu 24Vdc A Negative Ladung f r die Speisung der Zubeh re zu 24Vdc A TEST Positive Ladung f r die Speisung f r Fotozellen Selbstkontrolle J5 COM A Gemeinsame erdungskontakte Positive 2...

Page 46: ...hr Eingriff stoppt die Programmierung die LED DL1 blinkt nicht mehr N B Wenn die Eing nge STOP PHOT 1 PHOT 2 EDGE 1 und EDGE 2 nicht angeschlossen sind stellen Sie die Jumper zwischen COM A STOP PHOT...

Page 47: ...0 s dr cken und halten Sie die PROG Taste f r 5 s Die Speicherl schung wird durch zwei gr ne Blinksignale der LED DL12 und zwei Signalt ne des Summers angezeigt 3 Die LED DL12 blinkt erneut f r 10 s o...

Page 48: ...Verbinden Sie das Blinklicht mit dem Blinkerausgang Verwenden Sie Blinklichter ACG7072 von maximal 40W FUNKTION VORBLINKEN DIP 5 OFF Motor und Blinker starten gleichzeitig DIP 5 ON Blinker startet 3...

Page 49: ...Kontaktleiste Schaden Kontakt Fotozellen Schaden mit DIP 4 OFF Reparieren oder ersetzen Sie den fehlerhaften Kontakt Fotozellen Auto Test fehlgeschlagen berpr fen Sie die Verbindungen zwischen dem Be...

Page 50: ...unkcodes f r voll ffnung fussg nger ffnung R AUX relais 2 T ne Abgeschaltet Blinkt 2 mal gr n SIGNALISIERUNGEN W HREND DES BETRIEBS EREIGNIS STATUS BUZZER STATUS BLINKLEUCHTE LEDZUSTAND UND AUSGANGSSI...

Page 51: ...rte um Zugriff auf das Steuerungen hinzuzuf gen APP8064 WLAN Modul f r APP Karte Verwalten des Steuerung ber das lokale Wi Fi Netzwerk WLAN APP8066 RJ45 Modul f r APP Karte Verwalten der Steuerung ber...

Page 52: ...der elektrische Kontaktleiste Versorgung mit Mignon Batterien vom Typ AA zu 1 5V nicht im Lieferumfang enthalten RED erlaubt die Realisierung einer Anlage mit Kontaktleisten die auch auf dem sich bewe...

Page 53: ...sfuma las salidas las paradas y las inversiones de sentido de las enormes masas en movimiento Su motor autofrenante es til para limitar en parada la inercia de la puerta Medidas en mm 1 E S DISPOSICI...

Page 54: ...lica Personas expertas rea p blica Personas no expertas mantenido A B non posivel impulsivo a la vista por ejemplo bot n C o E C o E C e D o E impulsivo no a la vista p e mando a distancia remoto C o...

Page 55: ...GUE Permutar el aceite por primera vez dos meses despu s y a seguir cada a o ACEITES ACONSEJADOS AGIP OSO 35 SHELL TELLUS OIL 29 FINA HEDRAN 31 BP ENERGOIL HL 65 TERESSO 43 ARAL E 100 EXTRA MOBIL ATF...

Page 56: ...COM N BANDA 2 FOTOC LULA 2 BANDA 1 A TEST A AUTOPRUEBA DE FOTOC LULAS ANTENA 433 MHz ARMADURA ANTENA 24Vdc 0 4A 15 24Vdc 0 4A 15 700 W MAX CONEXI N EJECUTADA EN F BRICA TT Contacto termico motor T1 T2...

Page 57: ...A Negativo 24Vdc para alimentaci n accesorios A TEST Positivo 24Vdc para alimentaci n autotest fotoc lulas J5 COM A Com n de los contactos Positivo 24 Vdc B I O Contacto dedicado a un reloj NA PED Co...

Page 58: ...EN13849 1 su intervenci n detiene la programaci n el led DL1 del destello permanece iluminado constantemente N B Si las entradas de parada PHOT 1 PHOT 2 EDGE 1 y EDGE 2 no est n conectados realice pu...

Page 59: ...El tiempo de 10 s de programaci n de los c digos se renueva autom ticamente con el led DL12 que parpadea naranja durante 10 s para poder memorizar el mando a distancia sucesivo 3 Para terminar la prog...

Page 60: ...dio y el cierre automatico pondr n funcionar como programado Nota 1 durante el funcionamiento a hombre presente en caso de aver as con las perfiles sensibles o fotocelulas las fotocelulas o perfiles s...

Page 61: ...n el caso de que se detecte una falla se recomienda desconectar todos los conectores extra bles e insertarlos uno a la vez para identificar m s f cilmente la causa de la falla DEFECTO SOLUCI N Despu s...

Page 62: ...r c digos de radio 1000 c digos memorizados Apagado Apagado Realiza 6 parpadeos verdes Anulaci n c digos radio de apertura total peatonal y R AUX 2 Tonos Apagado Realiza 2 parpadeos verdes SE ALIZACIO...

Page 63: ...de control a trav s de Bluetooth 4 2 APP8064 M dulo wi fi para Tarjeta APP para administrar el panel de control a trav s de una red Wi Fi local WLAN APP8066 M dulo RJ45 para Tarjeta APP para administr...

Page 64: ...ja en movimiento sin la adopci n de sistemas recoge cables Conforme a la norma EN13849 1 2007 Unido a un cuadro electr nico RIB es un dispositivo de protecci n de Clase 2 c d ACG6202 E S NOVA NOVA WIR...

Page 65: ...self test 2 Fotozellen FIT SLIM FIT SYNCRO mit Selbstkontrolle 2 fotoc lulas FIT SLIM FIT SYNCRO con autotest 2 fotocellule F97P F97I con autotest 2 photocellules F97P F97I avec autotest 2 photocells...

Page 66: ...UTOTEST est activ e et qu une seule photocellule est connect e un cavalier doit tre cr entre les bornes PHOT 1 et PHOT 2 Si le cavalier n est pas ex cut l autotest choue et le portail ne bouge pas WAR...

Page 67: ...e CME3015 Flangia coperchio CME3016 Giunto innesto CME4015 Ingranaggio di traino CME5046 Piattello di fermo CME5050 Rondella CME5064 Rondella CME5104 Manopola di sblocco CME7012 Guida scorrimento moto...

Page 68: ...n Anforderungen gem Anhang I der Richtlinie UE 2006 42 CE angewendet wurden Die bereinstimmung mit den genannten harmonisierten Normen sieht die Vermutung der bereinstimmungmitdenfestgelegtengrundlege...

Reviews: