D - TIME PROGRAMMING FOR TWO MOTORS (#)

THIS CAN BE DONE IN EITHER OF TWO WAYS:
MODE 1 

-  WITH ENCODER (DIP 7 ON AND JUMPER S3 OPEN)

MODE 1         -  WITH  ENCODER  AND  ELECTRIC  LIMIT  SWITCHES  (IF  APPLIED)

(DIP 7 ON AND JUMPER S3 CLOSED)

MODE 1         -  WITHOUT  ENCODER  BUT  WITH  ELECTRIC  LIMIT  SWITCHES  (IF

APPLIED) (DIP 7 OFF AND JUMPER S3 CLOSED)

MODE 2  

- TIMED (DIP 7 OFF AND JUMPER S3 OPEN)

MODE 1 

1 - Start with the gate completely closed.
2 - Put DIP 2 in the ON mode => LED DL9 will blink rapidly.
3 - Press PROG. => M1 opens.
4 - When  the  gate  comes  into  contact  with  the  opening  stop,  the  ENCODER  stops  M1

(with  storage  of  the  encoder  readings  and  the  time)  and  M2  starts  to  open
simultaneously.

5 - When  the  gate  comes  into  contact  with  the  opening  stop,  the  ENCODER  stops  M1

(with storage of the encoder readings and the time) => the delay countdown prior  to
automatic closing starts simultaneously (max 5 minutes). 

6 - Press PROG. => delay countdown prior to automatic closing stops and M2 closes.
7 - Press PROG. => M1 closes and creates a phase difference between M2 and M1. At

the same time LED DL9 stops blinking to signal exit from the programming mode. 

At  this  point,  the  safety  devices  and  other  gate  controls  will  resume  normal  operation
(inversions, stops, alarms, etc.). 
9 - The gate will stop at the end of the ENCODER countdown.

10 - AFTER PROGRAMMING, SWITCH DIP 2 TO OFF.
NOTE: 

The same procedure applies to electric limit switches (S3 closed). With S3 closed,
gate  travel  is  determined  by  the  electric  limit  switches  and  not  by  the  encoder,
which only acts as a safety device.

MODE 2 

1 - Start with the gate completely closed.
2 - Put DIP 2 in the ON mode => LED DL9 will blink rapidly.
3 - Press PROG. => M1 opens.
4 - When  the  gate  comes  into  contact  with  the  opening  stop,  wait  one  second  and  then

press PROG => M1 stops and M2 opens.

5 - When  the  gate  comes  into  contact  with  the  opening  stop,  wait  one  second  and  then

press PROG => M2 stops and the delay countdown prior  to automatic closing starts
simultaneously (max 5 minutes). 

6 - Press PROG. => delay countdown prior to automatic closing stops and M2 closes.
7 - Press PROG. => M1 closes and creates a phase difference between M2 and M1. At

the same time LED DL9 stops blinking to signal exit from the programming mode. 

At  this  point,  the  safety  devices  and  other  gate  controls  will  resume  normal  operation
(inversions, stops, alarms, etc.). 
8 - The gate will stop at the end of the ENCODER countdown.

9 - AFTER PROGRAMMING, SWITCH DIP 2 TO OFF.

TIME PROGRAMMING FOR ONE MOTOR (#)

IMPORTANT: CUT OUT S2 TO OPERATE ONE MOTOR.

THIS CAN BE DONE IN EITHER OF TWO WAYS
MODE 3

- WITH ENCODER ONLY (DIP 7 ON AND JUMPER S3 OPEN)

MODE 3

- WITH ENCODER AND ELECTRIC LIMIT SWITCHES (IF APPLIED) (DIP 7

ON AND JUMPER S3 CLOSED)

MODE 3

- WITHOUT  ENCODER  BUT  WITH  ELECTRIC  LIMIT  SWITCHES  (IF

APPLIED) (DIP 7 OFF AND JUMPER S3 CLOSED)

MODE 4

- TIMED (DIP 7 OFF AND JUMPER S3 OPEN)

MODE 3  

1 - Start with the gate completely closed.
2 – Put DIP 2 in the ON mode => LED DL9 will blink rapidly.
3 - Press PROG. => M1 opens.
4 - When  the  gate  comes  into  contact  with  the  opening  stop,  the  ENCODER  stops  M1

(with storage of the encoder readings and the time) and the delay countdown priot to
automatic closing starts (max 5 minutes). 

5 - Press PROG. => delay countdown prior to automatic closing stops and M2 closes.
At the same time LED DL9 stops blinking to signal exit from the programming mode. 
At  this  point,  the  safety  devices  and  other  gate  controls  will  resume  normal  operation
(inversions, stops, alarms, etc.). 
6 - The gate will stop at the end of the ENCODER countdown.

7 - AFTER PROGRAMMING, SWITCH DIP 2 TO OFF.
NOTE

: The same procedure applies to electric limit switches (S3 closed). With S3 closed,

gate  travel  is  determined  by  the  electric  limit  switches  and  not  by  the  encoder,
which only acts as a safety device.

MODE 4 

1 - Start with the gate completely closed.
2 - Put DIP 2 in the ON mode => LED DL9 will blink rapidly.

3 - Press PROG. => M1 opens.
4 - When the gate comes into contact with the opening stop, wait one second then press

PROG. =>  M1 stops and the delay countdown prior  to automatic closing starts (max 5
minutes). 

5 - Press PROG. => delay countdown prior to automatic closing stops and M1 closes.
At the same time LED DL9 stops blinking to signal exit from the programming mode. 
At  this  point,  the  safety  devices  and  other  gate  controls  will  resume  normal  operation
(inversions, stops, alarms, etc.). 
6 - The gate will stop at the end of the ENCODER countdown.

7 - AFTER PROGRAMMING, SWITCH DIP 2 TO OFF.

(#)

SAFETY  DEVICES  ARE  ACTIVE  DURING  THE  PROGRAMMING  AND  THEIR

INTERVENTION  STOPS  IT  (THE 

LED    9

BLINKS  NO  MORE  BUT  REMAINS

CONSTANTLY TURNED ON).
TO  REPEAT  THE  PROGRAMMING,  POSITION  DIP1  AND  2  ON  MODE  OFF,  CLOSE
THE GATE AND REPEAT THE PROCEDURE DESCRIBED ABOVE.

OPERATION OF THE OPERATING ACCESSORIES

OPENING BUTTON (with timer function)

When the gate is standstill, the button operates the opening mode. If you push this button
when the gate is on closure, It opens again. 

TIMER FUNCTION 

This  function  is  useful  In  the  rush  hours,  when  vehicle  traffic  is  slow  (e.g.  entry/exit  of
workers, emergencies In residential or parking areas and, temporary, for removals).

APPLICATIONS

By connecting a switch and/or a daily/weekly timer (in place or in parallel with the opening
button  N.O.  “COM-OPEN”),  it  is  possible  to  open  the  automation  or  to  keep  It  open,  as
long as the switch is on or the timer is activated.
When the automation is open, all operating functions are inhibited.
If  the  automatic  closing  Is  started,  by  releasing  the  switch  or  at  the  time  set  before,  the
automation immediately closes; if not, you need to operate a command.

CLOSING BUTTON (COM-CLOSE)

When the gate is standstill, it operates the closing.

JOGGING OPERATION BUTTON (COM-K BUTTON)

DIP5 - OFF => It cyclically commands open-stop-close-stop-open-etc.
DIP5 - ON => It  opens  the  gate  when  this  Is  closed.  If  It  is  operated  while  the  gate  is

opening, it has no effect. If it is operated when the gate is open, it closes the
gate and, if it is operated while the gate is closing, it opens the gate again.

RADIO TRANSMITTER

DIP4 - OFF => It cyclically commands open-stop-close-stop-open-etc.
DIP4 - ON => It  opens  the  gate  when  this  is  closed.  If  it  is  operated  while  the  gate  is

opening, it has no effect. If it is operated when the gate is open, it closes. If
it is operated while the gate is closing, it opens the gate again.

AUTOMATIC CLOSING

Pause times before the automatic closing of the gate are set with the timing procedure.
The maximum pause time is 5 minutes.
Pause time can be started or stopped by DIP3 (ON started).

ELECTRIC LOCK IN OPENING PHASE 

Set Dip10 to ON to enable control of the electric lock in the opening phase. 

ELECTRIC LOCK AND RELEASE PULSE IN OPENING PHASE 

Set Dip11 to ON to enable the release pulse of the electric lock in the opening phase (provided
S2 Dip10 is set to ON). 
With the gate closed, pressing an opening command will cause the gate to perform the closing
movement  for  0.5s  (in  this  phase  the  Encoder(s)  is/are  not  enabled),  and  simultaneously  the
electric lock is activated (followed by 0.5s pause and then by opening of the gate).

GATE LEAF RELEASE ASSIST 

With  the  electric  lock  release  pulse  active  (Dip11  -  ON),  when  the  gate  is  closed  a  direction
reversal  manoeuvre  is  performed  for  a  fixed  time  of  0.2s  to  facilitate  manual  release  (in  this
phase the Encoder is not enabled).

OPERATION AFTER BLACK-OUT

When mains electrical power is restored press the opening button (K, OPEN, radio).
The gate will open. 

Let the gate close itself with automatic closure or wait that the flasher

stops  blink  first  to  command  the  closing  movement.  This  operation  is  valid  to  obtain  the
leaves position readjustment. 

During this phase all safety devices are active.

SAFETY ACCESSORIES OPERATION

SAFETY ENCODER (only for KING PLUS)

It  serves  as  a  safety  device  both  during  opening  and  on  closure,  with  movement
reversion.
DIP 7 (ON) OPERATES THE MOTOR WITH ENCODER.

If  the  Encoder  does  not  work  (due  to  a  failure  In  the  power  supply,  disconnected  wires,
broken or defective disk), the gate Is not operated.

E

N

G

L

I

S

H

Summary of Contents for KS2

Page 1: ...r il comando di uno o due motori monofasi Coffret electronique pour le contrôle de un ou deux moteurs monophase Electronic panel for the control of one or two single phase motors Elektronische Steuerung für ein oder zwei Einphasenmotoren Pag 1 di 24 I F GB D automatismi per cancelli automatic entry systems KS2 Mod ...

Page 2: ...ottemperanza alle norme ed alle leggi vigenti IMPORTANTES INSTRUCTIONS DE SECURITE POUR L INSTALLATION ATTENTION UNE INSTALLATION NON CORRECTE PEUT CAUSER DE GRAVES DOMMAGES SUIVRE TOUTES LES INSTRUCTIONS D INSTALLATION 1 Ce livret d instructions est adressé exclusivement à un personnel spécialisé qui connaît les critères de construction et les dispositifs de protection contre les accidents concer...

Page 3: ...DIE INSTALLATION ACHTUNG EINE UNKORREKTE INSTALLATION KANN SCHWERE SCHÄDEN VERURSACHEN ALLE INSTALLATIONSANLEITUNGEN BEFOLGEN 1 Diese Betriebsanleitung dient ausschließlich dem Fachpersonal welches die Konstruktionskriterien und die Sicherheits Vorschriften gegen Unfälle für Tore Türen und automatische Tore Kennt geltende Normen und Gesetze beachten und befolgen 2 Der Monteur muss dem Endkunde ein...

Page 4: ...igatoriamente per garantire il corretto funzionamento dell apparecchiatura Per garantire il corretto funzionamento dell impianto si consiglia di eseguire i collegamenti dell encoder e del motore installando cavi separati 1 S 2 3 GND 1 V 2 W 3 U SOLO KING PLUS M1 M2 Dove 1 2 3 sono i morsetti del connettore ai quali deve essere collegato un lato di ognuno dei tre fili non collegare la schermatura S...

Page 5: ...vato DIP 10 Abilitazione serratura elettrica ON attivato DIP 11 Abilitazione colpo di sgancio serratura elettrica ON attivata DIP 12 Motore a 230V OFF 120V ON S1 Pulsante per la programmazione PROG S2 Selezione funzionamento con 1 o 2 motori di default traccia chiusa 2 motori S3 Jumper selezione funzionamento a tempo OFF o con finecorsa elettrici ON se applicati TORQUE REGOLATORE ELETTRONICO DELLA...

Page 6: ... ferma il conteggio del tempo d attesa prima della chiusura automatica e M1 chiude Nello stesso istante il led DL9 smette di lampeggiare segnalando l uscita dalla procedura di apprendimento Da questo momento le sicurezze o altri comandi del cancello funzioneranno normalmente inversioni stop allarmi ecc 6 Finito il conteggio dell ENCODER il cancello si ferma 7 A FINE PROGRAMMAZIONE RIMETTERE IL DIP...

Page 7: ...icurezze allarme questo segnale sonoro aumenta la frequenza dell intermittenza SPIA DI SEGNALAZIONE CANCELLO APERTO COM SIGNAL Ha il compito di segnalare gli stati di cancello aperto parzialmente aperto o comunque non chiuso totalmente Solo a cancello completamente chiuso si spegne Durante la programmazione questa segnalazione non è attiva N B Se si eccede con le pulsantiere o con le lampade la lo...

Page 8: ... bobina di un relé così da attivare una o più lampade per un tempo minimo di 1 secondo e massimo di 4 minuti regolabile tramite il trimmer TR a bordo della scheda EXPANDER Il relé verrà attivato ad ogni apertura o chiusura GESTIONE SEMAFORO A cancello chiuso il semaforo è spento All apertura si accende la luce rossa 3 4 A cancello aperto si accende la luce verde 5 6 e si spegne la luce rossa La lu...

Page 9: ...âble blindé pour l encoder afin de garantir le bon fonctionnement du coffret de commande Pour les accessoires utiliser une section de câble de 0 75 mm2 1 S 2 3 GND 1 V 2 W 3 U M1 M2 SOULEMENT KING PLUS Là où 1 2 3 sont les bornes du connecteur dans lequel il faut brancher un bout de chacun des trois fils il ne faut pas brancher le blindage S GND sont les bornes du tableau électronique dans lequel ...

Page 10: ...odeur pour modèle PLUS ON activé DIP 8 Pré clignotement ON Clignotement normal OFF DIP 9 Vitesse réduite seulement en fermeture ON activé DIP 10 Serrure électrique ON activé DIP 11 Décrochage en ouverture ON activé DIP 12Moteur à 230V OFF 120V ON S1 PROG Touche destinée expressément à la programmation S2 Sélection fonctionnement avec 1 ou 2 moteurs de default trace fermée 2 moteurs S3 Jumper sélec...

Page 11: ... ON Le voyant lumineux DL9 émettra de brefs clignotements 3 Appuyer sur la touche PROG M1 ouvre 4 Après que la butée mécanique d ouverture ait été atteinte l ENCODEUR arrête M1 avec mémorisation des lectures de l encodeur et du temps et procède à l activation du comptage du temps d attente précédant la fermeture automatique max 5 minutes 5 Appuyer sur la touche PROG Le comptage du temps d attente ...

Page 12: ...e poussoir de STOP arrête le portail Si l on appuie sur ce poussoir lorsque le portail est complètement ouvert ou partiellement ouvert en utilisant la commande piétonne il exclut momentanément la fermeture automatique si cette dernière est sélectionnée à travers le DIP3 Il y a donc besoin d une nouvelle commande pour que le portail se referme Lors du cycle successif la fonction de fermeture automa...

Page 13: ...de pause peut être activé ou désactivé à travers le DIP3 ON activé CORDON EN OUVERTURE 11 12 Durant l ouverture si engagé inverse le mouvement en fermeture même si il reste engagée Durant la fermeture il n est pas actif Si il n est pas utilisé by passer les bornes 11 12 PHOTOCELLULE 2 9 12 Si la photocellule est interceptée lors de l ouverture elle invertit le mouvement à la fin de l interposition...

Page 14: ... It is compulsory to use shielded cable for the encoder in order to guarantee the correct operation of the control board To ensure the correct functioning of the installation it is advisable to wire encoder and motor with separate cables 1 S 2 3 GND 1 V 2 W 3 U M1 M2 ONLY KING PLUS Where 1 2 3 are the plugs of the connector where you have to insert one side of the 3 WIRES DO NOT CONNECT THE SHIELD...

Page 15: ... DIP 11 Release pulse in opening phase ON operated DIP 12 230V Motor OFF 120V ON S1 PROG Programming button S2 Select operation with 1 or 2 motors default closed track 2 motors S3 Timed operation jumper OFF or electric limit switches ON TORQUE ELECTRONIC TORQUE REGULATOR The torque is regulated by rotating the Trimmer TORQUE varying the output voltage of motor ends when rotated clockwise more torq...

Page 16: ...ontact with the opening stop wait one second then press PROG M1 stops and the delay countdown prior to automatic closing starts max 5 minutes 5 Press PROG delay countdown prior to automatic closing stops and M1 closes At the same time LED DL9 stops blinking to signal exit from the programming mode At this point the safety devices and other gate controls will resume normal operation inversions stop...

Page 17: ...generated inside safe power the control panel and it has been laid down in such a way to guarantee a double or strengthened insulation in relation to the parts with dangerous power Eventual external circuits connected to the outputs of the control board or of the expander card must be carried out making sure that a double or strengthened insulation is used in relation to parts with dangerous power...

Page 18: ...urns on when the gate is open and the red light turns off The green light remains turned on until the automatic closing starts When the gate closes the green light turns off and the red light turns on RADIO TRANSMITTER MOON CODE LEARNIG SYSTEM RADIORECEIVERS RX91 A quarzata and coupling code ACG5005 RX91 A quarzata and terminal board code ACG5004 RX433 A super eterodyne and coupling code ACG5055 R...

Page 19: ... Der Einsatz von abgeschirmtem Kabel ist ratsam da es sonst zu Fehlern im Programmablauf kommen kann Um ein korrektes arbeiten des Encoders zu garantieren beachten Sie die Installation der Anschlusskabel 1 S 2 3 GND 1 V 2 W 3 U M1 M2 NUR KING PLUS Wo 1 2 3 sind Klemmen des Konnektors an den jeweils ein Ende der drei Kabel angeschlossen werden muss die Abschirmung nicht anschließen S GND sind die K...

Page 20: ...e OFF automatisch ON DIP 5 Befehl Einzelimpuls K BUTT schrittweise OFF automatisch ON DIP 6 Fotozellen immer aktiv OFF Fotozellen nur beim Schließen aktiv ON DIP 7 Encoder für Modell PLUS ON aktiviert DIP 8 Vorblinken ON Normales Blinken OFF DIP 9 Langsame Geschwindigkeit nur beim Schließen ON aktiviert DIP 10 Elektroschloss ON aktiviert DIP 11 Entriegelung beim öffnen ON aktiviert DIP 12 Motor zu...

Page 21: ...3 1 Das Tor muss ganz geschlossen sein 2 Den Mikroschalter DIP 2 auf ON stellen Die LED DL9 blinkt in kurzen Abständen 3 Die Drucktaste PROG drücken M1 öffnet 4 Ist der mechanische Halt des Öffnungsvorganges erreicht stoppt der ENCODER M1 mit Speicherung der Ablesungen des Encoders und der Zeit Zur gleichen Zeit aktiviert sich die Wartezeitzählung vor der automatischen Schliessung max 5 Minuten 5 ...

Page 22: ...egen der Fußgänger Steuerung teilweise geöffnetem Tor betätigt wird schließt sie temporär das automatische Schließen aus wenn DIP3 ausgewählt sind Es ist also notwendig zum weiteren Schließen ein neues Kommando zu geben Beim Folgezyklus wird die automatische Schließfunktion erneut aktiviert wenn DIP3 ausgewählt sind BLINKLICHT ANMERKUNG Diese elektronische Tafel kann NUR BLINKER MIT BLINKSCHALTUNG...

Page 23: ...ließung wahrnimmt kehrt sie in die Öffnungsbewegung erst nach Durchgangsbeendigung um Diese Funktion kann besonders nützlich sein wenn man die unmittelbare Schließung des Tors wünscht als man durch die Torschwelle kommt Wenn man sie nicht anwendet die Klemmen 9 12 überbrücken HILFSLICHT 7 8 Es ist möglich die Spule eines Relais mit 24Vac zu versorgen so dass eine oder mehrere Lampen für die Dauer ...

Page 24: ...ne e successive modifiche per cui segnaliamo il divieto di messa in servizio prima che l impianto sia stato dichiarato conforme alle disposizioni della Direttiva Le présent dispositif ne peut fonctionner de manière indépendante étant prévu pour être intégré à une installation constituée d autres éléments Aussi rentre t il dans le champ d application de l art 4 paragraphe 2 de la Directive machines...

Reviews: