16
G
B
SYSTEM CHECK
After finishing the mounting procedure, check the correct working by doing the following:
-
Check on the infrared receiver RX VERTIGO that the red led is on. If it is not so, align
transmitter and receiver to turn the red led on.
-
Place an object between them and check that the red LED turns OFF and that at the same
time on the control panel the corresponding LED EDGE is OFF and a while the object is
present.
-
Repeat the process on the other VERTIGO photocells installed.
-
Then perform a system check of all the photocells installed by activating the movement of
the automation and checking that when an object is present the automation stops/reverses
when closing, or stops/continues to open when opening.
CLOSING THE VERTIGO CONTAINERS
Lastly, place the screw cover caps
(6) (12)
both on the TX and on the RX of the VERTIGO (Fig.
2-5), by inserting them into the 4 holes so that they are perfectly attached.
INFRARED SIGNAL RECEIVER - RX
TECHNICAL SPECIFICATIONS
VERTIGO RECEIVER
- POWER
12/24V ac/dc
- MAXIMUM ABSORPTION
25 mA
- OPERATING TEMPERATURE
-20°C ÷ +60°C
- COVER
in polycarbonate
- BASE
in ABS
- BELLOW
in silicon
- PROTECTION LEVEL
IP55
- WEIGHT
0,135 kg
VERTIGO TRANSMITTER
- POWER
12/24V ac/dc
- POWER ABSORBED
20 mA
- OPERATING TEMPERATURE
-20°C ÷ +60°C
- COVER
in polycarbonate
- BASE
in ABS
- BELLOW
in silicon
- PROTECTION LEVEL
IP55
- WEIGHT
0,130 kg
TX INFRARED SIGNAL TECHNICAL DETAILS
- RANGE
3 m
- WAVELENGTH
850 nm
- DIMENSION OF THE DETECTION AREA
diametre 20 mm
APPLICATION
MAX GATE
WEIGHT
MAX DISPLACEMENT
SPEED
VERTIGO 8
150 kg
300 kg
13 m/min.
10 m/min.
VERTIGO 10
500 kg
1000 kg
13 m/min.
10 m/min.
TROUBLESHOOTING
PROBLEM
CHECK
The green LED DLTX of the TX does not turns on as you give power supply.
- Check that on transmitter terminals is present the power supply 12/24V ac/dc
The red LED DLRX of the RX does not turns on as you give power supply.
- Check that on TX and RX terminals is present the power supply 12/24V ac/dc and the
correct allignment between them
The gate does not open.
VERTIGO is not aligned or stuck (red led on RX turned OFF). Check alignment between TX and
RX up to obtain red led turned on on RX.
The gate does not close.
AUTOTEST failed.
VERTIGO is not aligned or stuck (red led on RX turned OFF). Check alignment between TX and
RX up to obtain red led turned on on RX.
SELF-TEST-ENABLED RIB ELECTRONIC BOARD CHART
RIB ELECTRONIC BOARD
CONNECT A/D+
TEST TERMINAL TO
TERMINAL
ENABLE SELF-TEST
FUNCTION THROUGH
K2007 / K2007 CRX
A+ TEST
DIP 10
S1
A+ TEST
DIP 12
T2 - T2 CRX
D+ TEST
DIP 13
T2 24V - T2 24V CRX
A+ TEST
DIP 12