29

A  - SUPER 4000 operator
B - Photoelectric cells (external)
C - Rack
D - Key selector
E - Tuned aerial
F - Flashing lamp
H - Galvanized column for P.E. cells
I   -  Photo electric cells (internal)
L  -  Safety strip fixed to column
M - Mechanical or electrical safety strip with RED (Radio Edge Device) system 

Measurements in mm/inch

” 11,6

“5,6

“13

“7,36

“6,7

“11

“21,65

” 6,14

TECHNICAL FEATURES

Irreversible operating devices for sliding gates with a maximum weight of 4000 kg / 8800 lbs.  
The irreversibility of this operating device allows you to avoid using any electric lock for an effective 
closing of the gate. 
The motor is protected by an heat probe, that temporary interrupts the operating cycle in case of 
prolonged use.

1

TECHNICAL DATA

SUPER 4000

Max. leaf weight

kg/lbs

4000

Operating speed

m/s

0,165

0,198

Thrust force to constant turns

N

6600/5380

Max torque

Nm

280/226

Rack

M

6

Power supply

400V 3~ 50Hz

380V 3~ 60Hz

Motor capacity

W

1930

1920

Power absorbed

A

4

4,1

Normative cycles

100-72s/2s

Daily operations suggested

700

Service

%

100

Guaranteed consecutive cycles

700/10m

Lubrification

SHELL OMALA S2 G100

Weight of electroreducer

kg

47

Noise

db

<70

Working temperature

°C      

-10 ÷ +55

Protection

 IP

55

G

B

SYSTEM LAY-OUT

Summary of Contents for AA31030

Page 1: ...1 SUPER 4000 ICE sQ AA36075 Il corretto funzionamento dell operatore garantito solo se viene gestito da un quadro di comando RIB Le bon fonctionnement de l op rateur n est garanti que s il est g r par...

Page 2: ...ovocati dalla mancata osservanza nell installazione delle norme di sicurezza e delle leggi attualmente in vigore ATTENTION POUR LA SECURITE DES PERSONNES IL EST IMPORTANT DE SUIVRE TOUTES LES INSTRUCT...

Page 3: ...sed by the non observance during the installation of the safety standards and of the laws in force at present ACHTUNG F R DIE SICHERHEIT DER PERSONEN IST ES WICHTIG DASS ALLE ANWEISUNGEN GENAU AUSGEF...

Page 4: ...dell acquisto di una nuova apparecchiatura di tipo equivalente Presso i distributori di prodotti elettronici con superficie di vendita di almeno 400 m2 inoltre possibile consegnare gratuitamente senz...

Page 5: ...lettrica per un efficace chiusura Il motore protetto da una sonda termica che in caso di utilizzo prolungato interrompe momentaneamente il movimento I LAYOUT IMPIANTO CARATTERISTICHE TECNICHE SUPER 40...

Page 6: ...URA Persone esperte fuori da area pubblica Persone esperte area pubblica Persone non esperte mantenuto A B non possibile impulsivo in vista es pulsante C o E C o E C e D o E impulsivo non in vista es...

Page 7: ...Stabilito il senso di spostamento della camme H sia in apertura che in chiusura posizionare a vista i due finecorsa F agendo sui pomoli P Dopo aver verificato il corretto funzionamento elettrico dei...

Page 8: ...COSTA 2 FOTOCELLULA 2 COSTA 1 24Vdc 0 4A 15 24Vdc 0 4A 15 A TEST A AUTOTEST FOTOCELLULE ANTENNA 433 MHz SCHERMATURA CAVO D ANTENNA 700 W MAX CHIUDE APRE COMUNE ALIMENTAZIONE 400 Vac 50 Hz N COLLEGAMEN...

Page 9: ...ta 2 NC J7 COM A Comune dei contatti Positivo 24 Vdc LIMIT SWITCH Contatti finecorsa che fermano il motore J8 PROBE NON DISPONIBILE J9 ENCODER NON DISPONIBILE J10 Terminazione RS485 di J11 J11 APP Con...

Page 10: ...o fisso N B Se gli ingressi STOP PHOT 1 PHOT 2 EDGE 1 e EDGE 2 non sono collegati eseguire dei ponticelli tra COM A STOP PHOT 1 PHOT 2 EDGE 1 EDGE 2 prima di procedere con la programmazione N B In que...

Page 11: ...mpeggiare 4 Riposizionare DIP 1 2 e 3 su OFF CANCELLAZIONE DI TUTTI I CODICI RADIO PER REL R AUX La cancellazione pu essere eseguita solo a cancello fermo 1 Posizionare prima il DIP 1 su ON il DIP 2 s...

Page 12: ...uaste devono essere ripristinate per un corretto funzionamento SEGNALAZIONI VISIVE E SONORE LAMPEGGIATORE N B Questo quadro elettronico pu alimentare SOLO LAMPEGGIATORI CON CIRCUITO LAMPEGGIANTE ACG70...

Page 13: ...r 10 secondi DIP 1 ON DIP 3 ON programmazione codici radio apertura pedonale Spento Spento Lampeggia verde per 10 secondi DIP 1 ON DIP 2 ON DIP 3 ON programmazione codici radio per rel R AUX spento Sp...

Page 14: ...est fotocellule fallito verificare i collegamenti tra quadro elettronico e fotocellule Il cancello non apre e non chiude azionando i vari pulsanti START RADIO OPEN e CLOSE Contatto costa guasto Contat...

Page 15: ...e la centrale tramite rete Wi Fi locale WLAN APP8066 Modulo RJ45 per Scheda APP per gestire la centrale tramite rete dati locale LAN NOVA NOVA WIRELESS EN12978 EN13849 2 FOTOCELLULE NOVA portata 25 m...

Page 16: ...RE RADIO RED per costa meccanica o elettrica da alimentare con 3 batterie stilo tipo AA da 1 5V non incluse RED permette la realizzazione di un impianto con coste fissate anche sull anta in movimento...

Page 17: ...une fermeture efficace Le moteur est prot g par une sonde thermique qui interrompt momentan men le mouvement en cas de non utilisation prolong e Mesures en mm CARACTERISTIQUES TECHNIQUES SUPER 4000 Po...

Page 18: ...la norme EN 12453 TYPEDECOMMANDE USAGE DE LA FERMETURE Personne expertes zone sans publique Personne expertes zone avec publique Personnes non expertes homme presente A B Pas possible impulsion en vu...

Page 19: ...proc der au r glage D bloquer les crous G Une fois tabli le sens du mouvement de la came H en ouverture et en fermeture positionner vue les deux fins de course F en agissant sur les pommeaux P Apr s...

Page 20: ...E LED R 2 2K 1 4W COMMUN COMMUN COMMUN COMMUN CORDON 2 PHOTOCELLULES 2 CORDON 1 A TEST A AUTOTEST PHOTOCELULES ANTENNE 433 MHz ENVELOPPE ANTENNE 24Vdc 0 4A 15 24Vdc 0 4A 15 700 W MAX FERMETURE OUVERTU...

Page 21: ...llules 2 NF EDGE 1 Contact barres palpeuse 1 NF EDGE 2 Contact barres palpeuse 2 NF J7 COM A Commun des contacts Positif 24 Vdc LIMIT SWITCH Contact fin de course qui arr te la fermeture du moteur J8...

Page 22: ...ont actives et leur niveau de performance est PL c selon EN13849 1 leur intervention arr te la programmation le led DL1 reste allum N B Si les entr es STOP PHOT 1 PHOT 2 EDGE 1 et EDGE 2 ne sont pas c...

Page 23: ...ivante 3 Pour terminer la programmation laisser s couler 10 sec ou bien appuyer pendant un instant sur le bouton PROG La LED DL12 arr te de clignoter 4 Repositionner DIP 1 2 et 3 sur OFF PROCEDURE D E...

Page 24: ...rnement de la s curit dans ce mode si il est press ou en panne il ne permet pas de tout mouvement La manoeuvre con commande maintenue est exclusivement une manoeuvre d urgence qui doit tre effectu e p...

Page 25: ...le bouton START OPEN ou CLOSE le portail n effectue aucun mouvement Impulsion START OPEN ou CLOSE toujours ins r e Contr ler et remplacer les ventuels boutons ou microrupteurs du s lecteur SOLUTION D...

Page 26: ...Suppression codes ouverture totale pi ton et R AUX 2 Tonalit s teint Effectue 2 clignotements verts SIGNALISATIONS PENDANT LE FONCTIONNEMENT V NEMENT TAT BUZZER TAT CLIGNOTEUR TAT LED ET SORTIE SIGNA...

Page 27: ...le tableau de contr le via Bluetooth 4 2 APP8064 Module Wi Fi pour Carte APP pour g rer le tableau de contr le via un r seau Wi Fi local WLAN APP8066 Module RJ45 pour Carte APP pour g rer le tableau...

Page 28: ...NSMETTEUR RADIO RED pour barre palpeuse m canique ou lectrique alimenter par 3 piles de type AA de 1 5V non comprise RED permet la r alisation d une installation avec barres palpeuses fix es galement...

Page 29: ...llows you to avoid using any electric lock for an effective closing of the gate The motor is protected by an heat probe that temporary interrupts the operating cycle in case of prolonged use 1 TECHNIC...

Page 30: ...to install according to EN 12453 standard COMMAND TYPE USE OF THE SHUTTER Skilled persons out of public area Skilled persons public area Notskilled persons Hold to run operation A B Not possible Impul...

Page 31: ...TMENT Fig 8 To adjust the assembly release nuts G after establishing the direction of movement of cam H for opening and closing position the two limit switches F by turning knobs P and judging by sigh...

Page 32: ...LED R 2 2K 1 4W COMMON COMMON COMMON COMMON EDGE 2 PHOTOCELL 2 EDGE 1 A TEST A PHOTOCELLS AUTO TEST ANTENNA 433 MHz ANTENNA BRAIDING 24Vdc 0 4A 15 24Vdc 0 4A 15 700 W MAX CLOSE OPEN COMMON POWER SUPPL...

Page 33: ...ontact 2 NC EDGE 1 Edge 1 contact NC EDGE 2 Edge 2 contact NC J7 COM A Common contacts Positive 24 Vdc LIMIT SWITCH Limit switches that cuts OFF the motor J8 PROBE IS NOT AVAILABLE J9 ENCODER IS NOT A...

Page 34: ...ety Edge Photocells and Stop button will be ignored N B The start slow down point is automatically determined in the time programming phase and 50 60 cm is activated before reaching the opening or clo...

Page 35: ...M A B I O This function is useful during peak hours when vehicle traffic is slow e g entry exit of workers emergencies in parking or residential areas and temporarily for moving operations By connecti...

Page 36: ...ening limit switch After completing this first movement the operator will resume work at the set speed TECHNICAL SPECIFICATIONS Humidity 95 without condensation Power voltage 230V 10 120V 60Hz upon re...

Page 37: ...y 5 s for 1 minute It is renewed by giving a command Flashes for 1 minute No led combined Failed photocells auto test alarm 4 Tones every 5 s for 1 minute It is renewed by giving a command OFF No led...

Page 38: ...6 feet bars code ACS9090 NOVA NOVA WIRELESS EN12978 EN13849 2 PHOTOCELLS NOVA range 25 m code ACG8046 PHOTOCELLS NOVA WIRELESS range 25 m 3 years batteries life code ACG8047 PAIR OF COLUMNS for NOVA c...

Page 39: ...th 4 2 transmission APP8054 APP card to manage the control panel using Bluetooth 4 2 transmission APP8060 Clock module for APP card to add access control features to the control panel APP8064 Wi Fi mo...

Page 40: ...OUT WIRES code ACG3016 RED RADIO TRANSMITTER for mechanical and electrical safety strip Batteries not included RED allows to make a system made with edges fixed to the moving shutter without having to...

Page 41: ...ollen Verriegelung kein elektrisches Sicherheitsschloss Der Motor wird durch eine thermische Sonde gesch tzt die im Fall eines langen Einsatzes momentan die Bewegung unterbricht TECHNISCHE EIGENSCHAFT...

Page 42: ...ER SCHLIESSUNG Erfahrene Personen au erhalb des ffentlichen Bereichs Erfahrene Personen ffentlicher Bereich Nicht fachkundige Personen Gedr ckt halten A B nicht m glich Impulsiv in Sicht z B Wandtaste...

Page 43: ...ind nach Festlegung der Bewegungsrichtung des Nockens H f r ffnung und Schlie ung die beiden Endschalter F durch Bet tigung der Kn pfe P auf Sicht zu positionieren Nach berpr fung der beiden Mikroscha...

Page 44: ...ERDUNGSKONTAKT GEMEINSAMER ERDUNGSKONTAKT GEMEINSAMER GEMEINSAMER KONTAKTLEISTE 2 FOTOZELLE 2 KONTAKTLEISTE 1 A TEST A AUTOTEST FOTOZELLEN ANTENNE 433 MHz ANTENNE ZOPFFLECHTEN 24Vdc 0 4A 15 24Vdc 0 4...

Page 45: ...n Kontakt 1 NS PHOT 2 Fotozellen Kontakt 2 NS EDGE 1 Ripppen Kontakt 1 NS EDGE 2 Ripppen Kontakt 2 NS J7 COM A Gemeinsame erdungskontakte Positive 24 Vdc LIMIT SWITCH Steckverbinder f r elektrische od...

Page 46: ...pt die Programmierung die LED DL1 blinkt nicht mehr N B Wenn die Eing nge STOP PHOT 1 PHOT 2 EDGE 1 und EDGE 2 nicht angeschlossen sind stellen Sie die Jumper zwischen COM A STOP PHOT 1 PHOT 2 EDGE 1...

Page 47: ...0 s dr cken und halten Sie die PROG Taste f r 5 s Die Speicherl schung wird durch zwei gr ne Blinksignale der LED DL12 und zwei Signalt ne des Summers angezeigt 3 Die LED DL12 blinkt erneut f r 10 s o...

Page 48: ...lt werden sein VISUELLEN UND AKUSTISCHEN ALARMEN BLINKLICHT Verbinden Sie das Blinklicht mit dem Blinkerausgang Verwenden Sie Blinklichter ACG7072 von maximal 40W FUNKTION VORBLINKEN DIP 5 OFF Motor u...

Page 49: ...OFF Reparieren oder ersetzen Sie den fehlerhaften Kontakt Fotozellen Auto Test fehlgeschlagen berpr fen Sie die Verbindungen zwischen dem Bedienfeld und den Fotozellen Bei Bet tigung der START OPEN o...

Page 50: ...unkcodes f r voll ffnung fussg nger ffnung R AUX relais 2 T ne Abgeschaltet Blinkt 2 mal gr n SIGNALISIERUNGEN W HREND DES BETRIEBS EREIGNIS STATUS BUZZER STATUS BLINKLEUCHTE LEDZUSTAND UND AUSGANGSSI...

Page 51: ...rte um Zugriff auf das Steuerungen hinzuzuf gen APP8064 WLAN Modul f r APP Karte Verwalten des Steuerung ber das lokale Wi Fi Netzwerk WLAN APP8066 RJ45 Modul f r APP Karte Verwalten der Steuerung ber...

Page 52: ...der elektrische Kontaktleiste Versorgung mit Mignon Batterien vom Typ AA zu 1 5V nicht im Lieferumfang enthalten RED erlaubt die Realisierung einer Anlage mit Kontaktleisten die auch auf dem sich bewe...

Page 53: ...ra un cierre eficaz El motor est protegido por una sonda t rmica que en caso de uso prolongado interrumpe moment neamente el movimiento 1 CARACTER STICAS T CNICAS SUPER 4000 Peso m x verja kg 4000 Vel...

Page 54: ...3 TYPO DE MANDO USO DEL CIERRE Personas expertas fuera de un rea p blica Personas expertas rea p blica Personas no expertas mantenido A B non posivel impulsivo a la vista por ejemplo bot n C o E C o E...

Page 55: ...as tuercas G Una vez establecido el sentido de desplazamiento de la leva H para la apertura y el cierre colocar a ojo los dos finales de carrera F y accionar los pomos P Verificar el funcionamiento el...

Page 56: ...NDO LED R 2 2K 1 4W COM N COM N COM N COM N BANDA 2 FOTOC LULA 2 BANDA 1 A TEST A AUTOPRUEBA DE FOTOC LULAS ANTENA 433 MHz ARMADURA ANTENA 24Vdc 0 4A 15 24Vdc 0 4A 15 700 W MAX CIERRE ABRE COM N ALIME...

Page 57: ...NC PHOT 2 Contacto de las fotoc lulas 2 NC EDGE 1 Contacto banda de seguridad 1 NC EDGE 2 Contacto banda de seguridad 2 NC J7 COM A Com n de los contactos Positivo 24 Vdc LIMIT SWITCH Contactos de lo...

Page 58: ...ntervenci n detiene la programaci n el led DL1 del destello permanece iluminado constantemente N B Si las entradas de parada PHOT 1 PHOT 2 EDGE 1 y EDGE 2 no est n conectados realice puente entre COM...

Page 59: ...ente con el led DL12 que parpadea naranja durante 10 s para poder memorizar el mando a distancia sucesivo 3 Para terminar la programaci n deje transcurrir 10 s o presione por un instante el pulsador P...

Page 60: ...rante el funcionamiento a hombre presente en caso de aver as con las perfiles sensibles o fotocelulas las fotocelulas o perfiles sensibles trabajo mediante la interrupci n de la operaci n en curso Not...

Page 61: ...l caso de que se detecte una falla se recomienda desconectar todos los conectores extra bles e insertarlos uno a la vez para identificar m s f cilmente la causa de la falla DEFECTO SOLUCI N Despu s de...

Page 62: ...r c digos de radio 1000 c digos memorizados Apagado Apagado Realiza 6 parpadeos verdes Anulaci n c digos radio de apertura total peatonal y R AUX 2 Tonos Apagado Realiza 2 parpadeos verdes SE ALIZACIO...

Page 63: ...de control a trav s de Bluetooth 4 2 APP8064 M dulo wi fi para Tarjeta APP para administrar el panel de control a trav s de una red Wi Fi local WLAN APP8066 M dulo RJ45 para Tarjeta APP para administr...

Page 64: ...ja en movimiento sin la adopci n de sistemas recoge cables Conforme a la norma EN13849 1 2007 Unido a un cuadro electr nico RIB es un dispositivo de protecci n de Clase 2 c d ACG6202 E S NOVA NOVA WIR...

Page 65: ...self test 2 Fotozellen FIT SLIM FIT SYNCRO mit Selbstkontrolle 2 fotoc lulas FIT SLIM FIT SYNCRO con autotest 2 fotocellule F97P F97I con autotest 2 photocellules F97P F97I avec autotest 2 photocells...

Page 66: ...UTOTEST est activ e et qu une seule photocellule est connect e un cavalier doit tre cr entre les bornes PHOT 1 et PHOT 2 Si le cavalier n est pas ex cut l autotest choue et le portail ne bouge pas WAR...

Page 67: ...ione ingranaggio SUPER CCU6207 Cuscinetto 6207 35x72x17 CCU6307 Cuscinetto 6307 25x80x21 CEL1433 Pressacavo CME1034 Albero traino Super CME1063 Carcassa Super CME1079 Coperchio riduttore CME1095 Ganci...

Page 68: ...e UE 2006 42 CE angewendet wurden Die bereinstimmung mit den genannten harmonisierten Normen sieht die Vermutung der bereinstimmungmitdenfestgelegtengrundlegendenAnforderungen der Richtlinie vor die u...

Reviews: