Content
A). Product Features
...............................................................
2
B). Technology Specification
................................................
2
C). Operation
.........................................................................
2-7
D). Installation Drawing of 116E98
......................................
8
E). Drilling-bore Drawing
........................................................
9
F). FAQ
......................................................................................
10
A). Product Features
Main board adopts Philips CPU microcomputer chip-level design
Optional unlocking ways (fingerprint, password, keys)
B). Technology Specification
Capacity of Passwords
100 Groups
Capacity of admin passwords
1 Groups
Capacity of fingerprint
100pcs
Power Supply
DC4.5V
~
6.5V
,
4pcs of 1.5 No. 5 AA alkaline batteries
Static Current
< 30uA
Dynamic Current
< 150uA
Low power warning
It will be warning and lighting notice when power voltage is below 4.8V.
Executive body
DC micro motor
Service life
Be used for more than 300,000 times
C). Operation
Note:
Before using, you should firstly waken up the panel by touching it by your palm (please
see picture). The correct way to waken up the panel is to try as many fingers as possible to
touch the screen. After wakening up the panel, you can login the password or read the
fingerprint to open the lock.
The original unlocking password is “”#”
The original management password is “0000” (management password can’t be used to open
the lock)
1. Change the management password.
* (for 2s) + 7 + management pas # + new management pas #.
Settings finish.
Remarks: New management password will replace the old one.
1