Replace the battery
There is a 12V battery with one negative pole (-) grounded.
If battery cannot be charged or store any electricity, replace the battery with same model.
Replace the fuse.
If the electrical device does not work, please firstly check the fuse.
Important:
please install the fuse with correct amperage, so as to prevent against burning of electrical system due
to overloading!
Others
Parts
Quantity
Interval (h)
10
50
100
250
500
1000
2000
4000
Check if the bucket teeth is worn or
loosened.
★
Change the bucket
—
If needed
Replace the bucket and connect the
new one to machine.
—
If needed, replace the bucket and connect the new one to
machine.
Adjust the connecting rod of bucket
1
If needed
Take down the traveling lever
2
If needed
Check and replace the fuse
1
★
Every 3 years
Check the track defection
2
★
Maintenance of tensioner
2
★
Check the fuel injection timing
—
If needed
Measure the compression pressure of
engine
—
Check the starter and the A/C
generator
—
Check the bolts and nuts for
tightening torque
—
★
Note:
★
Maintenance interval under normal conditions
Maintenance needed at the first inspection
Contact dealers or Rhinoceros.
Check the bucket teeth --- each day
1. Check if the bucket teeth is worn or loosened.
Worn beyond the service limit, the bucket teeth may be replaced.
Bucket tooth dimensions mm
New
Service limit
190
130