background image

If removing this feature is a necessity, this can be achieved by connecting both the 

positive and negative power feed directly on to the car battery, this will override the 

current sensing feature in most cases.

 

 
 
 

               LOCK (ORANGE WIRE ON RCA)
                                                                                                    15A FUSE                      +12V

 (YELLOW PINK)            87                            87
             UNLOCK             87a                          87a
                                    86          85             86          85
                                             30                          30
                                                                                           LOCK OUTPUT

                                                                                      UNLOCK OUTPUT

INSTALL NEW DOOR LOCK MOTORS

 

 
 

               LOCK (ORANGE WIRE ON RCA)
                                                                                                    15A FUSE                 +12V

 (YELLOW PINK)            87                           87
             UNLOCK             87a                         87a
                                    86          85           86          85              MASTER LOCK SWITCH
                                          30                          30

                                                         LOCK OUTPUT

                                                          UNLOVK OUTPUT

                                                                TO EXISTING LOCK RELAY     +12V

5-WIRE “POLARITY REVERSING” POWER LOCK SYSTEM

 

 

          LOCK (ORANGE / BLACK FROM RCA)
                                                                                 TO EXISTING DOOR
                                                                                  RELAYS
          UNLOCK (YELLOW / PINK FROM RCA)

”NEGATIVE TRIGGER” ORIGINAL POWER LOCK SYSTEM

 

Summary of Contents for RCA

Page 1: ...RATED VIA REMOTE The panic is activated by pressing the button on the remote control transmitter for 3 seconds This sets off the siren To cancel panic press the button on the transmitter for 1 second TO ARM DISARM ALARM Alarm is activated by pressing the button on remote control transmitter The blinkers will flash once and siren will beep dash LED light will stay on for 20 seconds then flash ALARM...

Page 2: ...GATIVE OR POSITIVE SWITCHING DOORS SECURITY CIRCUIT PREVENTS ACCIDENTAL ARMING WHILE DRIVING TWO NORMALLY OPEN SECTORS IGNITION SENSING INPUT FLASHES BLINKERS ONCE TO ARM AND BEEPS SIREN FLASHES BLINKERS THREE TIMES TO DISARM FLASHES BLINKERS WHEN ALARM TRIGGERS 2 STAGE PULSE COUNT SHOCK SENSOR EXIT DELAY 20 SECONDS EXCEPTIONALLY LOW POWER CONSUMPTION RESET PERIOD 60 SECONDS POWER OUT FOR ACCESSOR...

Page 3: ...taller mode This is accomplished by pushing the button on remote control or turn ignition to on position 2 ALARM HISTORY MEMORY READ OUT VIA SIREN AND LED To access alarm memory turn ignition on and hood opened i e bonnet switch grounded By pressing the remote control alarm history is accessed via siren and LED 1 Beep 1 Flash Voltage Drop Alarm 2 Beep 2 Flashes Not Used On This Model 3 Beep 3 Flas...

Page 4: ...WIRES TO EITHER END OF THE STARTER FEED WIRE WHICH YOU HAVE JUST CUT YELLOW BLACK THIS IS A SWITCHED NEGATIVE OUTPUT VE 150mA CONNECT TO THE NEGATIVE WIRE USUALLY BLACK ON ANY ACCESSORY USED i e ULTRASONIC GLASS BREAKAGE MICROWAVE DETECTORS OR ETC LIGHT BLUE THIS IS A POSITIVE OR NEGATIVE TRIGGER AND SHOULD BE CONNECTED TO THE OUTPUT CIRCUIT WIRE ON ANY ACCESSORY TO BE USED ie ULTRASONIC MICROWAVE...

Page 5: ...e Pulse Central Lock outputs This must not be used unless a complete understanding of the car s central locking system is known Failure to do this can damage electronics and this damage WILL NOT BE COVERED UNDER WARRANTY If unsure please connect relays as shown on wiring instructions ...

Page 6: ...G TRIGGER VIOLET BLACK NEGATIVE OUT ON ALARM CONNECT THE BLACK 100mA MAX RING TO THE PINK SHOCK SENSOR PREWARN MOUNTING BOLT EARTH WIRE OUTPUT NEG 150mA YELLOW BLACK NEG OUT ON ARM 150mA ORIGINAL WIRE TO FUEL PUMP IGN 87 CONNECT FUEL PUMP DISABLE AS 86 87a 85 CUT DASHED LINE SHOWN 30 FUEL PUMP CURRENT SENSING The RCA alarm is fitted standard with current sensing This feature with the Rhino Austral...

Page 7: ...USE 12V YELLOW PINK 87 87 UNLOCK 87a 87a 86 85 86 85 30 30 LOCK OUTPUT UNLOCK OUTPUT INSTALL NEW DOOR LOCK MOTORS LOCK ORANGE WIRE ON RCA 15A FUSE 12V YELLOW PINK 87 87 UNLOCK 87a 87a 86 85 86 85 MASTER LOCK SWITCH 30 30 LOCK OUTPUT UNLOVK OUTPUT TO EXISTING LOCK RELAY 12V 5 WIRE POLARITY REVERSING POWER LOCK SYSTEM LOCK ORANGE BLACK FROM RCA TO EXISTING DOOR RELAYS UNLOCK YELLOW PINK FROM RCA NEG...

Page 8: ...V OR GROUND DENPENDING ON 12V SYSTEM REQUIREMENTS YELLOW PINK 87 87 UNLOCK 87a 87a 86 85 86 85 30 30 LOCK TO DRIVER SIDE LOCKING UNLOCK SWITCH LOCK TO PASSENGER UNLOCK SIDE LOCKING SWITCH 3 WIRE POSITVE TRIGGER POWER LOCK SYSTEM ...