background image

 

4

Auto Re-arm  

OFF 

If system is disarmed and a door is not opened 
within 60 seconds, the system will rearm & 
relock. 

Central Closure  

OFF 

When on, the lock & unlock outputs become a 5 
second negative pulse instead of 0.5 seconds. This 
feature is for certain vehicles with vacuum central 
locking or those with a central closure wire (some 
BMW, Mercedes) ie  doors lock, electric windows 
wind up, sunroof closes automatically. 

Door Lock on Ignition 

OFF 

When this feature is on, the doors will lock when 
the ignition is turned to on, and unlock when the 
ignition is turned to off. 

Shock Sensor 
Adjustment 

9 6 

SELECT the 

level 

required. 

After pressing the remote 9 times to enter this 
mode, turn the ignition to off. There are 8 levels 
of adjustment. The factory default setting is level 
6. Pressing the remote once will increase the 
sensitivity by one level ie to level 7. The LED will 
then flash seven times to confirm the new level. 
Pressing the remote again will increase the 
sensitivity to level 8 (max). Pressing the remote 
again will return the adjustment to level 1(least 
sensitive). Once you have adjusted the sensitivity 
level to the desired setting, turn the ignition on to 
exit this mode.  

PAT™ Past Alarm 
Trigger Memory 

10 SELECT 

to replay 

memory. 

After pressing the remote 10 times to enter this 
mode, turn the ignition off. Your Rhino Alarm offers 
a unique memory that stores the ten last reasons 
why the alarm was triggered. This memory cannot 
be erased. 
 
2 Beeps, 2 Flashes - Shock sensor alarm 
3 Beeps, 3 Flashes - Ignition       
4 Beeps, 4 Flashes - Power Fail Alarm 
6 Beeps, 6 Flashes - Negative trigger/Door 
 
If two previous alarms were recorded ie    voltage 
drop and shock sensor the LED will flash and the 
siren will beep once for voltage drop, then no noise 
for 1 second then beep three times for shock 
sensor. 

The last memory heard is the most 

recent alarm sector triggered. 

Turn the ignition to 

on to exit this mode. 
 

Installer Mode 

11 

SELECT The 

Mode 

Required 

After pressing the remote 11 times to enter this 
mode, turn the ignition to off. This mode allows the 
installer / owner to verify that each trigger of the 
alarm system is working, without having to arm & 
disarm the system each time & set off the siren. 
The siren will beep and the blinkers will flash to 
indicate a trigger eg  push the bonnet switch, open 
a door, hit the vehicle. The siren will beep four 
times to indicate a pre-warning  impact sensor 
detection, or once to indicate full alarm trigger 
level. Turn the ignition to on to exit this mode. 
 

 

Summary of Contents for GXa

Page 1: ...s in The siren will then sound the blinkers will flash for 30 seconds To cancel panic follow disarm procedure as desribed above NOTE Panic does not work when the ignition is on by requirement of Austr...

Page 2: ...n C Immediately press and hold the button on the new remote control for at least 5 seconds D Turn the vehicle s ignition off E The new remote control is now programmed into the alarm STANDARD SYSTEM F...

Page 3: ...activated via audible readout If a feature is enabled the siren will chirp out its code in beeps from the siren corresponding to the number shown in the column Press Remote This Many Times The siren i...

Page 4: ...g turn the ignition on to exit this mode PAT Past Alarm Trigger Memory 10 SELECT to replay memory After pressing the remote 10 times to enter this mode turn the ignition off Your Rhino Alarm offers a...

Page 5: ...a using more than one trigger device i e doors bonnet and impact sensor then the 1 Amp Diodes supplied must be used on each wire coming from each trigger input i e BLUE Negative LED Output Connect to...

Page 6: ...This wire must be 12 Volts only when the vehicle is being started Cut this wire The vehicle should not start Solder the starter motor side to number 30 on the relay Solder the other end to number 87...

Page 7: ...nce or a guarantee that such will not occur or that there will be no personal injury or property loss as a result Consequently The Company shall have no liability for any personal injury property dama...

Page 8: ...87 87 UNLOCK 87a 87a PULSE 86 85 86 85 30 30 LOCK OUTPUT UNLOCK OUTPUT NEGATIVE TRIGGER ORIGINAL CENTRAL LOCKING SYSTEM LOW CURRENT LOCK PULSE WIRE TO EXISTING ELECTRONIC INTERFACE UNLOCK PULSE WIRE...

Page 9: ...upply A to 12V Both pairs of lock unlock wires must be connected 12V 87 87 86 85 86 85 UNLOCK LOCK 30 30 15A Fuse IM PO R TA N T N O TE F O R IN STA LLE R S Vehicles fitted w ith negative or positive...

Reviews: